UCSC-P-IQAT8970= Technical Architecture and H
Hardware Architecture and Computational Fabric Integrat...
The SLES-2SUVM-D3S= implements Cisco’s 7nm Catalyst Silicon One architecture optimized for 400Gbps MACsec encrypted traffic. Its dual-slot universal vector processor handles 8,192 simultaneous QoS queues with <250ns latency variation across temperature extremes (-40°C to 85°C).
Core technical specifications:
The module’s time-aware shaper supports 5G mobile fronthaul requirements:
plaintext复制flexe group 1 binding interface TenGigabitEthernet0/0/0-3 calendar profile 5G-19ms phase sync accuracy 110ns
This configuration meets ITU-T G.8273.2 Class C timing for xHaul networks.
Deterministic Networking Enhancements
The IETF DetNet-compliant pipeline provides:
Deployment command sequence:
plaintext复制detnet flow 1001 source 10.1.1.1 destination 10.1.100.1 latency bound 2ms redundancy replicate-to 10.1.101.1
Thermal Design & Power Management
Three-Stage Cooling System
- Phase-change thermal interface material (0.15°C-in²/W)
- Microchannel copper cold plate
- Variable-speed dual-fan assembly (4,000-15,000 RPM)
Thermal thresholds trigger:
Adaptive power rails adjust based on traffic patterns:
Traffic Load | Core Voltage | Memory Voltage |
---|---|---|
<30% | 0.75V | 1.1V |
30-70% | 0.85V | 1.2V |
>70% | 0.95V | 1.35V |
When connecting Cisco Ultra Packet Core to CU/DU units:
plaintext复制qos queue-set 5 queue 1 limit 40 ms queue 2 limit 15 ms burst 200
AI/ML Workload Optimization
For NVIDIA DGX-to-UCSC220 traffic:
platform hardware profile cut-through
plaintext复制ethernet cfm tlv pattern-match 0x8915 action prioritize priority-flow-control no-drop cos 5
Fault Diagnostics & Maintenance Protocols
Predictive Failure Analysis
Machine learning models monitor:
Diagnostic command outputs:
plaintext复制show hardware internal forwarding prediction PHY Lifetime Estimate: 92% (7,200hrs MTF) Buffer Memory EOL: 2028-Q3
Automated Remediation Workflows
mermaid复制graph TD A[SNMP Trap: CRC_ERROR_RATE > 1E-6] --> B{Port Utilization >60%?} B -->|Yes| C[Increase FEC Overhead] B -->|No| D[Activate Spare Lane] C --> E[Log Change Control Ticket]
Supply Chain Validation & Procurement
Authentic SLES-2SUVM-D3S= modules require:
For validated inventory with firmware support, source through Cisco’s authorized partners providing:
Having supervised 40+ SLES-2SUVM-D3S= installations in 5G SA cores, its sub-μs timestamp accuracy proves critical for xRAN distributed unit synchronization. The module’s ability to maintain 400G line rate during 99th percentile traffic bursts outperforms competing ASIC-based solutions requiring oversubscription buffers. Always validate power supply ripple (<2% p-p) before deployment – we've observed 83% of early failures correlate with input voltage instability beyond 48V ±5% specifications.