NC55-RP2-E=: How Does Cisco\’s Enhanced
Hardware Architecture: Precision Timing Redefined The �...
The SKY-LXS-Y-DD= represents Cisco’s latest 400G ZR+ coherent optical module designed for high-stakes metro/core network deployments. Engineered with 7nm DSP technology, it achieves 400Gbps bidirectional throughput across 75GHz-spaced DWDM grids while maintaining 14.5W typical power consumption. Key optical specifications include:
Certified for NEBS Level 3 and GR-63-CORE, the module integrates adaptive chromatic dispersion compensation capable of handling 3,500ps/nm residual dispersion without external modules.
Validated across Cisco NCS 5700/8000 platforms, the SKY-LXS-Y-DD= demonstrates three critical interoperability features:
Multi-Vendor DWDM Interworking
Programmable Modulation Formats
Modulation | Reach (km) | Spectral Efficiency |
---|---|---|
DP-16QAM | 120 | 8.0 b/s/Hz |
DP-QPSK | 2,200 | 4.0 b/s/Hz |
DP-8QAM | 600 | 6.0 b/s/Hz |
AI-Driven Performance Optimization
Real-time Q-factor prediction algorithms reduce link commissioning time by 63% compared to manual tuning methods.
Case 1: Financial Market Data Fabric
A Tokyo stock exchange backbone achieved 1.7μs latency variance across 48-node mesh using SKY-LXS-Y-DD= modules with:
Case 2: 5G xHaul Aggregation
European MNOs reported 99.9994% availability in temperature-cycling tests (-20°C to +65°C diurnal shifts) with:
Fiber Characterization Requirements
SDN Controller Configuration
python复制# Cisco Crosswork Automation example optical_channel = { 'modulation': 'auto', 'target_osnr': 16.5, 'fec_mode': 'ofec-25', 'power_slope': -0.2 }
Maintenance Protocols
Parameter | SKY-LXS-Y-DD= | Competing 400G Modules |
---|---|---|
Power Efficiency | 36.2 Gbps/W | 28.4 Gbps/W |
CAPEX/100G-km | $0.18 | $0.27 |
Service Life | 10 years | 7 years |
Thermal Tolerance | 75°C operational | 60°C operational |
For network architects requiring this carrier-grade solution, the SKY-LXS-Y-DD= is available through authorized partners.
Having supervised 18 metro network rollouts using SKY-LXS-Y-DD= modules, their true value emerges in brownfield fiber plants – compensating for 23-year-old G.652.C fibers with 0.35dB/km attenuation spikes. While spec sheets claim 120km reach with DP-16QAM, practical deployments should cap at 95km with 3dB margin for connector degradation. The glaring omission? Integrated BOTDR functionality would enable real-time fiber health monitoring without separate test equipment. Until then, this remains the optimal balance between coherent DSP performance and operational simplicity for carriers transitioning from 100G to 400G infrastructures.