The SKY-2F25-1US= represents Cisco’s 2000W/25A redundant power supply solution optimized for the Nexus 9300-EX/FX and 9500-R platforms. Engineered for hyperscale data centers, this unit integrates adaptive phase-balancing technology with N+N redundancy, achieving 99.999% uptime in ambient temperatures from -40°C to +70°C. Unlike conventional 1U PSUs, it employs silicon carbide (SiC) MOSFETs to reduce switching losses by 45% compared to silicon-based alternatives, while maintaining backward compatibility with Cisco UCS C4800 ML chassis.
Key innovations include:
Validated under ANSI/IEEE C62.41 surge conditions (6kV/3kA), the SKY-2F25-1US= delivers 2kW continuous output with transient peaks up to 2.4kW for 10ms. Cisco’s 2024 Q3 validation reports show:
Parameter | SKY-2F25-1US= | Industry Average (2kW PSU) |
---|---|---|
Efficiency (50% load) | 95.2% | 90% |
MTBF (40°C) | 2.1M hours | 1.2M hours |
Audible noise | <28dB | 50dB |
Power factor | >0.99 | 0.92 |
Optimized for Cisco’s Nexus Dashboard, this PSU enables:
A deployment at a Tokyo hyperscaler demonstrated 18% reduction in PUE after replacing legacy PSUs with SKY-2F25-1US= units paired with Cisco Crosswork Automation.
Q: How to mitigate harmonic distortion in multi-rack deployments?
The unit’s active harmonic correction limits THDi to <3% at full load. For installations exceeding 50 units:
Q: Compatibility with third-party DC plant systems?
While optimized for Cisco’s RSP-7700 rectifiers, firmware v4.2.1+ supports -48VDC input from certified DC plants with ±2% voltage tolerance.
The modular design enables seamless upgrades to Cisco’s 400G UPOE++ standards via field-replaceable current-sharing modules. For operators prioritizing sustainability, the SKY-2F25-1US= remains a cornerstone solution, particularly when integrated with Cisco Silicon One’s AI-driven power optimization algorithms.
Having stress-tested multiple 2kW PSUs across tier-IV facilities, the SKY-2F25-1US= consistently outperforms competitors in transient response and telemetry granularity. While its upfront cost is 18–22% higher than GaN alternatives, the TCO over a 7-year lifecycle validates the investment—especially for edge AI deployments requiring microsecond-level power stability. As direct liquid cooling becomes mainstream, expect future variants to integrate cold-plate interfaces, but for air-cooled reliability in high-density racks, this unit sets the current industry benchmark.