​E100D-SSD-480G: Core Technical Profile​

The ​​E100D-SSD-480G​​ is a Cisco-certified 480GB solid-state drive designed for ​​UCS C-Series servers​​ and ​​HyperFlex HX-Series nodes​​. Built for enterprise workloads, it uses a ​​2.5-inch SATA III​​ interface with ​​6Gbps throughput​​ and supports ​​hot-swapping​​ in redundant storage configurations. Unlike consumer-grade SSDs, it features ​​power-loss protection (PLP)​​ and ​​TLC NAND​​ optimized for mixed read/write operations.


​Key Specifications and Endurance Metrics​

  • ​Capacity​​: 480GB (raw), ~440GB usable after RAID overhead
  • ​Sequential Read/Write​​: ​​550 MB/s​​ (read), ​​520 MB/s​​ (write)
  • ​Random IOPS​​: 98k (read), 35k (write) at 4K block size
  • ​Endurance​​: 1.3 PBW (Petabytes Written) over 5-year warranty
  • ​Form Factor​​: 2.5-inch, 7mm height (fits UCS 220/240/480 chassis)
  • ​Operating Temp​​: 0°C to 70°C (non-condensing)

​Compatibility: Supported Cisco Platforms​

System Minimum Firmware Use Case
UCS C220 M5 4.0(4g) Boot drive for ESXi hosts
HyperFlex HXAF240C 4.5(2a) Caching for VDI workloads
UCS S3260 Storage 3.1(3d) Metadata storage for Ceph

​Note​​: Not compatible with ​​UCS B-Series blades​​ or ​​Nexus 9000 switches​​ due to backplane voltage differences.


​Performance vs. Competing Drives​

Parameter E100D-SSD-480G UCS X440C-M6 (960GB) HDD 1TB 7.2K RPM
Latency (Avg.) 0.2 ms 0.15 ms 8 ms
IOPS (4K Random) 35k 75k 80
Power Draw (Active) 3.5W 5W 6.8W

​Takeaway​​: The E100D balances cost and performance for mid-tier storage needs but lags behind NVMe-based drives in high-throughput scenarios.


​Critical Use Cases​

​1. Virtualization Host Boot Drives​

Replacing HDDs with the E100D-SSD-480G reduces ESXi/vSphere host boot times from ~5 minutes to ​​under 20 seconds​​.

​2. HyperFlex Edge Clusters​

In HyperFlex HX220c nodes, two E100D SSDs in RAID 1 provide ​​fail-safe caching​​ for edge sites with limited rack space.

​3. Kubernetes Persistent Volumes​

For lightweight containerized databases (e.g., Redis, PostgreSQL), the drive’s ​​1.3 PBW endurance​​ ensures reliable long-term storage.


​User Concerns Addressed​

​Q: Can this SSD be used to upgrade older UCS C240 M4 servers?​

​A​​: No. The M4 generation lacks SATA III controller support. Minimum requirement is ​​UCS C220 M5​​ with firmware 4.0(4g).

​Q: Does PLP protect against sudden power failures during writes?​

​A​​: Yes. The onboard capacitors provide ​​~50 ms​​ of sustained power to flush DRAM buffers to NAND.

​Q: Is hardware encryption supported?​

​A​​: No. The E100D lacks ​​SED (Self-Encrypting Drive)​​ functionality. Use software encryption like LUKS or BitLocker.


​Common Deployment Pitfalls​

  • ​Overprovisioning Neglect​​: Allocating 100% capacity reduces write endurance. Reserve ​​7-10%​​ via Cisco UCS Manager.
  • ​Firmware Mismatches​​: Drives shipped with ​​22.3.2 firmware​​ may cause compatibility issues with HyperFlex 4.0 nodes. Upgrade to ​​23.1.1​​ before deployment.
  • ​Thermal Throttling​​: In densely packed UCS S3260 shelves, ambient temps above 35°C trigger throttling, cutting speeds by 40%.

​Purchasing and Legacy Support​

Cisco has phased out the E100D-SSD-480G in favor of NVMe drives like the ​​X440C-M6​​, but refurbished units with 90-day warranties are available. For verified stock, visit [“E100D-SSD-480G=” link to (https://itmall.sale/product-category/cisco/).


​Is the E100D Still a Viable Option in 2024?​

While NVMe dominates modern data centers, the E100D-SSD-480G remains cost-effective for SMBs or labs running legacy UCS infrastructure. Its ​​1.3 PBW rating​​ and ​​PLP​​ justify retention in non-critical roles like backup repositories or cold storage. However, for AI/ML workloads or real-time analytics, upgrading to Cisco’s X-Series NVMe drives is non-negotiable.