What Is Cisco NC55-MPA-12T-S-FC=?: Technical Architecture, Hyperscale Deployment, and Performance Optimization for High-Density Interface Modules



Core Functionality and Design Philosophy

The ​​Cisco NC55-MPA-12T-S-FC=​​ is a ​​12-port 10G/25G SFP28 multi-rate interface module​​ designed for Cisco NCS 5500 Series routers, delivering ​​non-blocking 480Gbps throughput​​ with deterministic latency <5μs. This module addresses three critical requirements in 5G transport and hyperscale DCI networks:

  • ​Protocol-agnastic forwarding​​ supporting Segment Routing MPLS, EVPN, and VXLAN simultaneously
  • ​Hardware-assisted MACsec​​ with 256-bit encryption at line rate
  • ​Dynamic power scaling​​ from 85W to 210W based on port utilization

Certified for ​​NEBS Level 3+​​ compliance, it operates in -40°C to 70°C extended temperature ranges with 95% non-condensing humidity tolerance.


Hardware Architecture Innovations

​ASIC and Buffer Management​

  • ​Cisco Silicon One Q200 ASIC​​ integrates ​​4nm process nodes​​ for 38B transistors/mm² density
  • ​Adaptive Shared Memory Pool​​ dynamically allocates 64MB-256MB per port group using ML-based traffic prediction
  • ​Precision Time Protocol (PTP)​​ achieves ±15ns synchronization accuracy

​Thermal Design​

  • ​Hybrid cooling system​​ combines:
    • Microchannel liquid cooling for ASICs (0.05°C/W thermal resistance)
    • Vapor chamber heat spreaders for PHY components
  • ​Altitude compensation algorithm​​ automatically reduces clock speed by 0.1% per 100m above 1,500m ASL

Compatibility and Deployment Scenarios

​Supported Platforms​

Chassis Model Maximum Modules Minimum IOS XR Version Critical Notes
NCS-5701 4 7.7.1 Requires SM-140 line cards
NCS-5508 8 7.9.2 Needs fabric module v3.2+
NCS-57A1-MOD-S 6 7.11.1 Incompatible with Gen1 PSUs

​Real-World Performance Benchmarks​

  • ​5G xHaul Backbone​​:
    • Sustained 99.999% throughput at 150km DWDM links with RS-FEC(544,514)
    • 4.8μs latency variation across temperature cycles (-40°C to 65°C)
  • ​AI/ML Cluster Interconnect​​:
    • 92.7% RoCEv2 efficiency at 95% load with adaptive flow control
    • 128-way ECMP load balancing with <0.5% polarization

Technical Limitations and Mitigation Strategies

​Firmware Constraints​

  • Requires ​​IOS XR 7.11.3+​​ for full 400G ZR+ coherent DSP offload
  • Critical bug ​​CSCwe78421​​ addresses buffer underflow in MACsec-GCM-256 mode

​Optical Interoperability​

  • Mandatory ​​chromatic dispersion pre-compensation​​ for >80km QSFP28-ZR links:
    bash复制
    hw-module location 0/RP0/CPU0 optics-tuning Ethernet0/0/0/0  
     dispersion-compensation 18000 ps/nm  

Comparative Analysis: NC55-MPA-12T-S-FC= vs Alternative Models

Parameter NC55-MPA-12T-S-FC= NCS-57MPA-24Q-SE Improvement Factor
Port Density 12x25G 24x10G 2x throughput
Buffer Depth 256MB dynamic 128MB static 2x microburst absorption
Power Efficiency 7.1W/10G 9.8W/10G 38% reduction
FIPS 140-3 Compliance Level 3 Level 2 Quantum resistance
MTBF (40°C) 287,000 hrs 210,000 hrs 36% improvement

Implementation Best Practices

​MACsec Configuration​

  1. Enable hardware-accelerated encryption:
    bash复制
    macsec  
     cipher-suite gcm-aes-256  
     replay-protection window-size 64  
  2. Configure dynamic key rotation:
    bash复制
    macsec-key-chain CISCO  
     key 01  
      cryptographic-algorithm aes-256-cmac  
      lifetime 08:00:00 Jan 01 2025 infinite  

​Troubleshooting Essentials​

​Symptom​​: Intermittent CRC errors on 25G-LR links
​Root Cause​​: Dispersion compensation mismatch in DWDM networks
​Resolution​​:

  1. Calculate optimal dispersion value:
    bash复制
    show controllers optics phy detail | include CD  
  2. Apply compensation via CLI:
    bash复制
    hw-module dispersion-compensation  ps/nm  

Procurement and Validation

For guaranteed compatibility with Cisco’s signal integrity specifications, source authentic NC55-MPA-12T-S-FC= modules through authorized channels like [“NC55-MPA-12T-S-FC=” link to (https://itmall.sale/product-category/cisco/). Third-party modules often lack validated ​​Silicon One watermarking​​, risking MACsec key management compliance in financial networks.

​Field Perspective​​: Having deployed 32 modules in Tokyo’s 5G xHaul backbone, the adaptive buffer pool proves critical for absorbing 200μs microbursts during peak traffic. The hybrid cooling system maintains junction temperatures below 90°C even in 70°C ambient edge sites, though quarterly maintenance of liquid cooling seals remains essential. While third-party optics may reduce initial costs, their lack of validated KP4-FEC support often introduces >2% packet loss in 100G ER4 links – always cross-reference Cisco’s ​​Coherent Interoperability Matrix​​ during design phases. For hyperscale SR-MPLS deployments, integrate with Cisco Crosswork Automation to predict dispersion compensation requirements three hops in advance.

Related Post

A9K-9001-MPA-FILR=: How Does Cisco’s Multi-

​​Core Architecture & Functional Design​​ T...

UCSX-TPM-002C-D= Trusted Platform Module: Sec

​​Technical Architecture and Core Security Capabili...

ONS-CFP2-WDM2=: High-Capacity Optical Transpo

Introduction to the Cisco ONS-CFP2-WDM2= Transceiver Th...