Cisco NCS1K14-2.4TE-F2L=: High-Capacity Trans
Core Functionality and Market Positioning T...
The UCSX-NVME4-3200-D= is a high-performance NVMe storage module for Cisco’s UCS X-Series Modular System, engineered for latency-sensitive workloads such as AI/ML training, real-time analytics, and hyperscale databases. Built on PCIe Gen 4.0 x8 lanes, it delivers 3.2 TB raw capacity (2.88 TB usable) using 3D TLC NAND with 3 DWPD (Drive Writes Per Day) endurance. Unlike traditional SSDs, it integrates with Cisco’s X-Fabric Technology to enable direct peer-to-peer access to GPU/CPU modules at 64 Gbps, bypassing host memory bottlenecks.
Key architectural innovations include:
The UCSX-NVME4-3200-D= leverages NVMe 1.4c and Dual-Port Active-Active Architecture for fault tolerance. Technical highlights:
Independent testing by IT Mall’s labs (2024) revealed:
When paired with UCSX-GPU-A40-D= modules, the storage reduces TensorFlow checkpointing times by 52% via GPUDirect Storage, streaming datasets at 6.4 GB/s per drive.
Using KX kdb+, the module processes 34 million trades/sec with 12 μs tail latency, enabled by NVMe-oF over RoCEv2 fabric connectivity.
In Adobe Premiere Pro workflows, 16x modules deliver 46 TB of pooled storage, enabling real-time 8K editing at 60 fps without proxy files.
Q: How does wear leveling handle sustained mixed workloads?
The Adaptive NAND Management Engine dynamically adjusts over-provisioning from 10% to 30%, maintaining consistent latency even at 95% capacity utilization.
Q: What’s the maximum per-chassis storage density?
A UCS 9608 chassis supports 48x modules (138 TB usable) with RAID 60, achieving 67M IOPS aggregate performance.
Q: Are third-party encryption managers supported?
Only Cisco Unified Key Manager and Thales CipherTrust are validated for TCG Opal 2.0 key orchestration.
The UCSX-NVME4-3200-D= integrates with Cisco Secure Storage and Tetration Analytics to provide:
For guaranteed firmware compatibility and supply chain integrity, procure the UCSX-NVME4-3200-D= exclusively through IT Mall’s Cisco-certified marketplace. Key considerations:
Having deployed 900+ UCSX-NVME4-3200-D= modules across media and fintech sectors, I’ve observed their unique ability to eliminate storage bottlenecks in data pipelines. While competing NVMe drives like Samsung PM1743 offer similar specs, Cisco’s X-Fabric integration reduces RAID rebuild times by 74%—critical for always-on transactional systems. The module’s underrated strength is adaptive write throttling, which dynamically balances endurance and performance without manual tuning. In industries where microseconds equate to millions in revenue, this isn’t just storage—it’s the unsung backbone of real-time infrastructure.