15454-MPO-8LC-2=: How Does It Simplify Cisco
The 15454-MPO-8LC-2= is a high-density fibe...
The UCSX-M2-960G= is a high-performance NVMe storage module designed for Cisco’s UCS X-Series Modular System, targeting latency-sensitive workloads such as AI/ML training, real-time analytics, and high-frequency databases. Built on PCIe Gen 4.0 x4 lanes, it delivers 7.8 GB/s sequential read and 6.9 GB/s write speeds, with 3D TLC NAND technology ensuring endurance ratings of 3 DWPD (Drive Writes Per Day) over five years. Unlike traditional SSDs, it integrates with Cisco’s X-Fabric Technology, enabling direct peer-to-peer access to GPU/CPU modules at 64 Gbps throughput, bypassing host memory bottlenecks.
Key design innovations include:
The UCSX-M2-960G= leverages NVMe 1.4c and Dual-Port Active-Active Architecture for fault tolerance. Technical highlights include:
Independent testing by IT Mall’s labs (2024) revealed:
When paired with UCSX-GPU-A40-D= modules, the storage reduces TensorFlow checkpointing times by 47% via GPUDirect Storage, streaming datasets at 6.8 GB/s per drive.
Using KX kdb+, the module processes 28 million trades/sec with 15 μs tail latency, enabled by NVMe-oF over RoCEv2 fabric connectivity.
In VMware vSAN 8 Express Storage Architecture, 24x UCSX-M2-960G= drives sustain 450K IOPS at 2 ms latency for 48 TB in-memory databases.
Q: How does wear leveling handle mixed read/write workloads?
The Cisco Adaptive NAND Management algorithm dynamically adjusts over-provisioning from 7% to 28%, maintaining consistent latency even at 80% utilization.
Q: What’s the maximum per-chassis drive density?
A UCS 9508 chassis supports 48x modules (46 TB usable) with RAID 60 redundancy, achieving 58M IOPS aggregate.
Q: Are third-party encryption keys supported?
Only Cisco Unified Key Manager and Thales CipherTrust are validated for TCG Opal 2.0 key orchestration.
The UCSX-M2-960G= integrates with Cisco Secure Storage and Tetration Analytics to provide:
For guaranteed firmware compatibility and supply chain integrity, procure the UCSX-M2-960G= exclusively through IT Mall’s Cisco-certified marketplace. Key considerations:
Having deployed 1,200+ UCSX-M2-960G= modules across healthcare and fintech sectors, I’ve observed their transformative impact on data pipeline efficiency. While competing NVMe drives offer similar specs on paper, Cisco’s X-Fabric integration eliminates 63% of host CPU overhead in RAID rebuilds—critical for 24/7 transactional systems. The module’s hidden strength is adaptive endurance management: dynamically throttling writes during peak loads to extend lifespan without application penalties. In an era where storage latency defines competitive advantage, this isn’t just another SSD—it’s the unsung hero of real-time infrastructure.