​Introduction to the UCS-NVME4-7680=​

The ​​UCS-NVME4-7680=​​ is a Cisco-certified, high-density NVMe SSD designed for ​​Cisco UCS C-Series and X-Series servers​​, delivering ​​7.68TB​​ of raw capacity with ​​PCIe 4.0 x4​​ performance. Optimized for data-intensive workloads like AI/ML training, real-time analytics, and hyperscale virtualization, this drive combines ​​3D TLC NAND​​ technology with enterprise-grade durability to meet the demands of modern data centers. With ​​7.4GB/s sequential read speeds​​ and advanced power-loss protection, it addresses the need for scalable, low-latency storage in hybrid cloud and HPC environments.


​Core Technical Specifications​

​1. Hardware Architecture​

  • ​Capacity​​: 7.68TB (formatted, 512e/4Kn sector support).
  • ​Interface​​: PCIe 4.0 x4 (NVMe 1.4), backward-compatible with PCIe 3.0.
  • ​Form Factor​​: 2.5-inch U.2 (SFF-8639), 15mm height.
  • ​Flash Type​​: ​​144-layer 3D TLC NAND​​ with dynamic SLC caching.

​2. Performance Metrics​

  • ​Sequential Read/Write​​: 7,400/6,800 MB/s (128KB blocks).
  • ​Random Read/Write​​: 1.5M/1.3M IOPS (4KB blocks, QD256).
  • ​Latency​​: <70µs read, <20µs write (99.9% percentile).

​3. Reliability and Security​

  • ​Endurance​​: 1.0 DWPD (Drive Writes Per Day) over 5 years.
  • ​Encryption​​: AES 256-bit (FIPS 140-3) with TCG Opal 2.0/SED support.
  • ​MTBF​​: 2.5 million hours.

​Compatibility and Integration​

​1. Cisco UCS Ecosystem​

  • ​Servers​​: UCS C220 M7, C240 M7, UCS X9508 Modular System.
  • ​Controllers​​: Cisco 16G SAS/NVMe Tri-Mode RAID Controller (UCSC-PSMV16G).
  • ​Management​​: Cisco UCS Manager 5.3+, Intersight Predictive Storage Analytics.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 8.0 U3, Red Hat OpenShift 4.14.
  • ​Databases​​: SAP HANA (TDI 2.0), Oracle Exadata X10M, Cassandra 5.0.

​3. Limitations​

  • ​PCIe Gen3 Bottlenecks​​: Max throughput limited to 3.5GB/s in PCIe 3.0 slots.
  • ​Thermal Constraints​​: Requires chassis airflow >40 CFM for sustained performance.

​Deployment Scenarios​

​1. AI/ML and HPC Workloads​

  • ​Distributed Training​​: Cache multi-terabyte datasets for PyTorch/TensorFlow clusters.
  • ​Genomic Sequencing​​: Achieve 2M+ reads/sec in RAID 0 configurations.

​2. Financial Analytics​

  • ​Real-Time Risk Modeling​​: Execute 50M Monte Carlo simulations/hour.
  • ​Blockchain Ledgers​​: Sustain 500K TPS for Hyperledger Fabric networks.

​3. Virtualization and Cloud​

  • ​VMware vSAN ESA​​: Dedicate as capacity tier for all-flash clusters.
  • ​Kubernetes Storage​​: Allocate local persistent volumes (LPVs) for AI/ML pipelines.

​Operational Best Practices​

​1. RAID and Tiering Strategies​

  • ​RAID 5​​: Use for archival storage with 8+ drives to balance capacity and redundancy.
  • ​Tiered Workloads​​: Pair with Cisco UCS S3260 Storage Servers for cold data tiering.

​2. Firmware and Health Management​

  • ​Updates​​: Apply firmware ​​4.2.1+​​ to resolve PCIe link training instability.
  • ​Monitoring​​: Track ​​Media Wear Indicators (MWI)​​ via Intersight telemetry dashboards.

​3. Thermal and Power Optimization​

  • ​Cooling​​: Deploy ​​Cisco UCS 40mm High-Static Fans​​ in dense server configurations.
  • ​Power Allocation​​: Reserve 30W per drive bay in fully populated UCS X9508 chassis.

​Addressing Critical User Concerns​

​Q: Can UCS-NVME4-7680= SSDs replace SAS SSDs in existing UCS C240 M6 servers?​
Yes—but ensure the server has PCIe Gen4 slots and a compatible Tri-Mode RAID controller (UCSC-PSMV16G+).

​Q: How to mitigate “I/O Queue Full” errors in high-concurrency environments?​

  1. Increase NVMe submission/completion queue pairs via OS tuning (e.g., Linux NVMe driver parameters).
  2. Enable ​​Multi-Path I/O (MPIO)​​ for failover and load balancing.

​Q: Does SED encryption degrade PostgreSQL performance?​
Minimal—AES-NI offloading limits overhead to <2% for OLTP workloads.


​Procurement and Lifecycle Support​

For validated configurations, source the UCS-NVME4-7680= from [“UCS-NVME4-7680=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 5-year warranty and 24/7 TAC support.


​Observations from Hyperscale Deployments​

In a hyperscaler’s AI training cluster, 1,000+ UCS-NVME4-7680= drives reduced model checkpointing times by 50% compared to Gen3 SSDs. However, RAID 6 rebuilds for 7.68TB drives took 12+ hours—optimized by implementing erasure coding with 10+2 parity. While PCIe Gen5 adoption looms, this drive’s balance of capacity and Gen4 throughput makes it ideal for enterprises prioritizing TCO over bleeding-edge specs. The encryption overhead’s near-negligible impact on performance reinforces its viability for regulated industries. Yet, the drive’s 1.0 DWPD endurance may challenge write-heavy Kafka deployments, necessitating careful workload profiling. The lesson? Storage innovation isn’t just about speed; it’s about aligning endurance, security, and scalability to sustain—not just accelerate—digital transformation.

Related Post

Resolving High CPU Usage on Cisco Nexus 9000

The Cisco Nexus 9000 series switches are renowned for t...

Cisco NCS2K-9-SMR34FS-L= Technical Deep Dive:

​​NCS2K-9-SMR34FS-L= Overview: Multi-Rate Flexibili...

Cisco UCSX-440P-NEW-D: Next-Gen PCIe Expansio

Architectural Innovation & Hardware Specifications ...