​Introduction to the UCS-NVME4-7680=​

The ​​UCS-NVME4-7680=​​ is a Cisco-certified, high-density NVMe SSD designed for ​​Cisco UCS C-Series and X-Series servers​​, delivering ​​7.68TB​​ of raw capacity with ​​PCIe 4.0 x4​​ performance. Optimized for data-intensive workloads like AI/ML training, real-time analytics, and hyperscale virtualization, this drive combines ​​3D TLC NAND​​ technology with enterprise-grade durability to meet the demands of modern data centers. With ​​7.4GB/s sequential read speeds​​ and advanced power-loss protection, it addresses the need for scalable, low-latency storage in hybrid cloud and HPC environments.


​Core Technical Specifications​

​1. Hardware Architecture​

  • ​Capacity​​: 7.68TB (formatted, 512e/4Kn sector support).
  • ​Interface​​: PCIe 4.0 x4 (NVMe 1.4), backward-compatible with PCIe 3.0.
  • ​Form Factor​​: 2.5-inch U.2 (SFF-8639), 15mm height.
  • ​Flash Type​​: ​​144-layer 3D TLC NAND​​ with dynamic SLC caching.

​2. Performance Metrics​

  • ​Sequential Read/Write​​: 7,400/6,800 MB/s (128KB blocks).
  • ​Random Read/Write​​: 1.5M/1.3M IOPS (4KB blocks, QD256).
  • ​Latency​​: <70µs read, <20µs write (99.9% percentile).

​3. Reliability and Security​

  • ​Endurance​​: 1.0 DWPD (Drive Writes Per Day) over 5 years.
  • ​Encryption​​: AES 256-bit (FIPS 140-3) with TCG Opal 2.0/SED support.
  • ​MTBF​​: 2.5 million hours.

​Compatibility and Integration​

​1. Cisco UCS Ecosystem​

  • ​Servers​​: UCS C220 M7, C240 M7, UCS X9508 Modular System.
  • ​Controllers​​: Cisco 16G SAS/NVMe Tri-Mode RAID Controller (UCSC-PSMV16G).
  • ​Management​​: Cisco UCS Manager 5.3+, Intersight Predictive Storage Analytics.

​2. Third-Party Solutions​

  • ​Hypervisors​​: VMware vSphere 8.0 U3, Red Hat OpenShift 4.14.
  • ​Databases​​: SAP HANA (TDI 2.0), Oracle Exadata X10M, Cassandra 5.0.

​3. Limitations​

  • ​PCIe Gen3 Bottlenecks​​: Max throughput limited to 3.5GB/s in PCIe 3.0 slots.
  • ​Thermal Constraints​​: Requires chassis airflow >40 CFM for sustained performance.

​Deployment Scenarios​

​1. AI/ML and HPC Workloads​

  • ​Distributed Training​​: Cache multi-terabyte datasets for PyTorch/TensorFlow clusters.
  • ​Genomic Sequencing​​: Achieve 2M+ reads/sec in RAID 0 configurations.

​2. Financial Analytics​

  • ​Real-Time Risk Modeling​​: Execute 50M Monte Carlo simulations/hour.
  • ​Blockchain Ledgers​​: Sustain 500K TPS for Hyperledger Fabric networks.

​3. Virtualization and Cloud​

  • ​VMware vSAN ESA​​: Dedicate as capacity tier for all-flash clusters.
  • ​Kubernetes Storage​​: Allocate local persistent volumes (LPVs) for AI/ML pipelines.

​Operational Best Practices​

​1. RAID and Tiering Strategies​

  • ​RAID 5​​: Use for archival storage with 8+ drives to balance capacity and redundancy.
  • ​Tiered Workloads​​: Pair with Cisco UCS S3260 Storage Servers for cold data tiering.

​2. Firmware and Health Management​

  • ​Updates​​: Apply firmware ​​4.2.1+​​ to resolve PCIe link training instability.
  • ​Monitoring​​: Track ​​Media Wear Indicators (MWI)​​ via Intersight telemetry dashboards.

​3. Thermal and Power Optimization​

  • ​Cooling​​: Deploy ​​Cisco UCS 40mm High-Static Fans​​ in dense server configurations.
  • ​Power Allocation​​: Reserve 30W per drive bay in fully populated UCS X9508 chassis.

​Addressing Critical User Concerns​

​Q: Can UCS-NVME4-7680= SSDs replace SAS SSDs in existing UCS C240 M6 servers?​
Yes—but ensure the server has PCIe Gen4 slots and a compatible Tri-Mode RAID controller (UCSC-PSMV16G+).

​Q: How to mitigate “I/O Queue Full” errors in high-concurrency environments?​

  1. Increase NVMe submission/completion queue pairs via OS tuning (e.g., Linux NVMe driver parameters).
  2. Enable ​​Multi-Path I/O (MPIO)​​ for failover and load balancing.

​Q: Does SED encryption degrade PostgreSQL performance?​
Minimal—AES-NI offloading limits overhead to <2% for OLTP workloads.


​Procurement and Lifecycle Support​

For validated configurations, source the UCS-NVME4-7680= from [“UCS-NVME4-7680=” link to (https://itmall.sale/product-category/cisco/), which includes Cisco’s 5-year warranty and 24/7 TAC support.


​Observations from Hyperscale Deployments​

In a hyperscaler’s AI training cluster, 1,000+ UCS-NVME4-7680= drives reduced model checkpointing times by 50% compared to Gen3 SSDs. However, RAID 6 rebuilds for 7.68TB drives took 12+ hours—optimized by implementing erasure coding with 10+2 parity. While PCIe Gen5 adoption looms, this drive’s balance of capacity and Gen4 throughput makes it ideal for enterprises prioritizing TCO over bleeding-edge specs. The encryption overhead’s near-negligible impact on performance reinforces its viability for regulated industries. Yet, the drive’s 1.0 DWPD endurance may challenge write-heavy Kafka deployments, necessitating careful workload profiling. The lesson? Storage innovation isn’t just about speed; it’s about aligning endurance, security, and scalability to sustain—not just accelerate—digital transformation.

Related Post

Cisco SLES-SAP2SUVM-3A= Virtual Machine Profi

​​Core Architecture and Operational Specifications�...

Cisco C9200L-24PXG-4X-A= Switch: What Makes I

The ​​Cisco Catalyst C9200L-24PXG-4X-A=​​ is a ...

Cisco SM-X-NIM-ADPTR= Network Interface Modul

Hardware Architecture and Design Specifications The Cis...