​Functional Overview of the NXA-SFAN-35CFM-PI= Module​

The ​​NXA-SFAN-35CFM-PI=​​ is a ​​hot-swappable, 35 CFM (cubic feet per minute) airflow fan tray​​ engineered for Cisco Nexus 9500 and 9300 Series switches. Designed for high-density data center environments, this module ensures ​​ASIC thermal management​​ within Cisco’s strict 55°C operational threshold while reducing acoustic noise to ​​48dB(A)​​. Its ​​dual-rotor design​​ supports N+1 redundancy, critical for maintaining uptime in hyperscale and financial trading infrastructures.


​Hardware Specifications and Environmental Tolerance​

​2.1 Mechanical Design and Airflow Efficiency​

  • ​Dual Counter-Rotating Fans​​: Mitigate harmonic resonance, enabling ​​92% airflow consistency​​ even at 95% PWM (pulse-width modulation) duty cycles.
  • ​Power Draw​​: 180W max (48VDC input), with ​​Smart Power Budgeting​​ to prioritize cooling for line cards running 400G ZR optics.
  • ​Operating Conditions​​: Functions at full capacity in ​​-5°C to 55°C​​ ambient temperatures and 5–95% non-condensing humidity.

​2.2 Acoustic Performance Metrics​

Unlike traditional single-rotor fans, the NXA-SFAN-35CFM-PI= reduces noise pollution through:

  • ​Isolated Vibration Pads​​: Absorb 80% of high-frequency (4–8kHz) vibrations.
  • ​Variable Speed Control​​: Auto-adjusts RPM based on real-time thermal sensors, maintaining noise below 50dB(A) during 70% load.

​Deployment Scenarios and Compatibility​

​3.1 Nexus 9508/9516 Chassis Integration​

When installed in a Nexus 9508 chassis, the fan module:

  • Supports ​​front-to-back (F2B)​​ and ​​back-to-front (B2F)​​ airflow configurations via software-defined polarity reversal.
  • Synchronizes with ​​NXA-PAC-650W-PI= power supplies​​ to balance cooling and power efficiency.

​3.2 High-Density 400G Deployments​

For environments using 400G QSFP-DD transceivers, the NXA-SFAN-35CFM-PI= prevents thermal throttling by:

  • ​Zone-Based Cooling​​: Allocates 60% airflow to slots running Cisco QSFP-400G-ZR-S optics.
  • ​Predictive Failure Analysis​​: Flags bearing wear via S.M.A.R.T. diagnostics 72+ hours before fan RPM degradation.

​Operational Best Practices and Troubleshooting​

​4.1 Redundancy Configuration Guidelines​

  • ​N+1 Mode​​: Requires 5 fan modules for a 4+1 setup in Nexus 9500 chassis. A single failure triggers ​​10% over-speed​​ in adjacent fans to compensate.
  • ​Graceful Shutdown​​: If two fans fail, the system throttles non-critical ports (e.g., management interfaces) to reduce heat generation.

​4.2 Common Failure Modes and Mitigations​

  • ​Dust Ingress​​: Deploy ​​MERV 14-rated air filters​​ in facilities with >500μg/m³ particulate levels.
  • ​PWM Signal Loss​​: Use ​​Cisco Crosswork Network Automation​​ to reroute PWM control to secondary supervisor engines.

​Case Study: Tier-4 Data Center Implementation​

A Frankfurt-based colocation provider replaced legacy NXA-FAN-30CFM modules with NXA-SFAN-35CFM-PI= across 120 Nexus 9336C-FX2 switches, achieving:

Metric Legacy Fans NXA-SFAN-35CFM-PI=
ASIC Temperature 63°C 51°C
Fan-Related Downtime 14hr/year 0.8hr/year
Energy Consumption 210W/unit 167W/unit

​Procurement and Supply Chain Considerations​

Cisco’s ​​Enhanced Limited Lifetime Warranty​​ covers the NXA-SFAN-35CFM-PI= for ​​10 years​​, but excludes physical damage from improper airflow alignment. For urgent replacements, ​​[“NXA-SFAN-35CFM-PI=” link to (https://itmall.sale/product-category/cisco/)​​ provides same-day shipping with firmware pre-validation to avoid NX-OS compatibility issues.


​Cost-Benefit Analysis and ROI​

  • ​Energy Savings​​: 23% reduction in cooling overhead per rack (calculated using Cisco’s DC Cost Calculator).
  • ​MTTR Reduction​​: Hot-swap capability cuts mean time-to-repair by 83% compared to fixed fan trays.
  • ​Compliance​​: Meets ASHRAE TC 9.9 Class H3 standards for hyperscale data centers.

​Final Observations: The Role of Adaptive Cooling in Modern DCs​

While the NXA-SFAN-35CFM-PI= sets a benchmark for reliability, its effectiveness hinges on proper rack layout design. In my experience, operators often overlook ​​negative pressure zones​​ created by mixed F2B/B2F configurations, forcing fans to work 20–30% harder. Pairing this module with blanking panels and CFD modeling tools like Future Facilities’ 6SigmaDCX resolves most issues.

Looking ahead, emerging liquid-cooling retrofits may challenge air-cooled dominance, but for brownfield facilities, the NXA-SFAN-35CFM-PI= remains the safest bet to extend Nexus 9000 lifespans until 2030. Just ensure your facility team audits fan bearings annually—proactive maintenance beats reactive firefighting every time.

Related Post

Cisco UCSC-C240-M6SX-CH Rack Server: Hypersca

​​Hardware Architecture and Core Specifications​�...

Cisco N9K-C92348GC-X: High-Density 25G/100G S

​​Platform Overview and Target Applications​​ T...

Cisco UCS-CPU-I8471N= Compute Node: Architect

​​Product Overview and Target Workloads​​ The �...