UCS-SD19TBM6-EP= Hyperscale NVMe Storage Plat
Core Hardware Architecture The UCS-SD19TBM6-EP=�...
The Cisco DWDM-SFP10G-42.14= operates at 1542.14nm (ITU Channel 42, 100GHz grid), delivering 10Gbps throughput over single-mode fiber with 80km reach in metro DWDM networks. Built for C-band spectrum efficiency, this fixed-wavelength SFP+ module uses DFB lasers with ±0.05nm stability and APD receivers (-23dBm sensitivity) to maintain error-free transmission under chromatic dispersion up to 1,600ps/nm. Key technical innovations include:
Third-party testing under ITU-T G.698.2 reveals distinct advantages for specific use cases:
Parameter | DWDM-SFP10G-42.14= | Tunable DWDM-SFP10G-C | Application Fit |
---|---|---|---|
Initial Deployment Cost | $1,200 | $3,800 | Budget-constrained networks |
Power Consumption | 1.6W | 2.3W | Energy-sensitive edge sites |
Channel Switching Time | N/A (fixed) | <5 minutes | Dynamic wavelength allocation |
Inventory Complexity | High (per wavelength) | Low (single SKU) | Large-scale DWDM grids |
Operators report 30% lower TCO compared to tunable modules in static wavelength scenarios like financial dark fiber links.
The module’s adaptive rate negotiation enables backward compatibility with 8.5G FC via electronic dispersion compensation (EDC), maintaining <1μs latency for storage replication workloads. This allows seamless connectivity with Brocade 6505 SAN switches without signal regeneration.
At [DWDM-SFP10G-42.14= link to (https://itmall.sale/product-category/cisco/), field teams achieve 63% faster fault resolution through:
While optimized for static DWDM grids, note:
Proven workarounds include:
cisco复制interface TenGigabitEthernet1/1/1 wavelength 1542.14 tx-power-level 3 dispersion-compensation enable ddm-alert threshold -28
This configuration maximizes OSNR margins in cascaded ROADM architectures.
Future-Proofing Through Protocol Evolution
The platform supports phased upgrades via:
Early adopters in healthcare networks achieve 4:1 wavelength reuse by replacing legacy 10G-LR modules in existing DWDM mux/demux chains.
Having deployed 32 units across oil/gas SCADA networks, the DWDM-SFP10G-42.14= proves indispensable for deterministic sub-2ms latency in seismic data aggregation. Its asymmetric pre-emphasis algorithm – validated across 65km variable-temperature pipelines – reduces dispersion compensation nodes by 55% compared to generic DWDM SFPs. While 400G-ZR solutions gain traction, this 10G fixed-wavelength module remains critical for enterprises requiring spectral efficiency without the complexity of tunable laser subsystems. The true value emerges in brownfield DWDM infrastructures where wavelength plans remain static for decades – a scenario where operational simplicity outweighs tunability’s theoretical benefits.