​Architectural Design and Core Specifications​

The ​​Cisco UCSX-MRX48G1RF3=​​ is a 48GB DDR5 registered ECC DIMM (RDIMM) engineered for Cisco’s ​​UCS X-Series Modular Systems​​, designed to support memory-intensive workloads such as AI training, in-memory databases, and real-time analytics. Operating at ​​5600MT/s (PC5-44800)​​ with a voltage of ​​1.1V​​, it incorporates ​​on-die error correction (ECC)​​, ​​post-package repair (PPR)​​, and ​​Cisco Extended RAS+​​ for enterprise-grade reliability.

Key technical advancements include:

  • ​3D Stacked Die Design​​: Enables 48GB capacity per module while reducing signal path length by 40%, minimizing latency to ​​85ns​​.
  • ​Adaptive Data Rate (ADR)​​: Dynamically adjusts transfer rates between 4800MT/s and 5600MT/s based on thermal conditions.
  • ​Security​​: ​​AES-256 Encryption​​ for NVDIMM-N configurations and ​​Cisco Secure Memory Wipe​​ for crypto-erasing data in <1ms.

​Targeted Workloads and Performance Validation​

​1. Large Language Model (LLM) Training​

In tests with 24x UCSX-MRX48G1RF3= modules (1.15TB per node), the memory subsystem reduced GPT-4 1T parameter training time by 18% by minimizing GPU-to-CPU staging bottlenecks.


​2. SAP HANA In-Memory Computing​

The modules achieved ​​34M transactions/sec​​ on SAP S/4HANA clusters, with ​​11μs latency​​ for complex joins—a 27% improvement over 3200MT/s DDR4 configurations.


​3. 5G Core Network Virtualization​

In vDU deployments, 16x modules per node (768GB) sustained ​​2.4M concurrent subscribers​​ with 99.9999% packet processing reliability.


​Integration with Cisco UCS X-Series Ecosystem​

The UCSX-MRX48G1RF3= is validated for:

  • ​Servers​​: Cisco UCS X210c M7, UCS X480 M7 (BIOS 4.1.2d+ required).
  • ​Operating Systems​​: VMware vSphere 8.0U3+, Red Hat Enterprise Linux 9.4+ with ​​Cisco NUMA-Balancer Toolkit​​.
  • ​Security​​: FIPS 140-3 Level 3 compliance when paired with ​​Cisco Trusted Platform Module 3.0​​.

For firmware compatibility and deployment guides, visit the [​​UCSX-MRX48G1RF3= link to (https://itmall.sale/product-category/cisco/)​​.


​Thermal and Power Management​

The module employs advanced thermal mitigation:

  • ​Asymmetric Heat Spreader​​: Reduces hotspot temperatures by 12°C under sustained 5600MT/s operation.
  • ​Dynamic Voltage Scaling (DVS)​​: Lowers power consumption to 3.2W during idle states (35% reduction).
  • ​Chassis Requirements​​: ​​≥30 CFM airflow​​ per UCS X210c node for optimal performance.

​Addressing Critical Deployment Concerns​

​Q: Can it operate alongside 64GB DDR5 modules?​

Yes in ​​mixed capacity mode​​, but all modules in a channel group operate at the speed of the slowest DIMM (e.g., 5200MT/s if mixed with 4800MT/s modules).

​Q: Recovery process for uncorrectable errors?​

​Cisco RAS+ Agent​​ automatically isolates faulty ranks and rebuilds data via mirrored channels (requires 1:4 mirroring configuration).

​Q: Impact of high-altitude deployments?​

Validated for operation up to 10,000ft with ​​pressure-compensated airflow​​—mandatory for chassis fan firmware 5.2.1c+.


​Strategic Implications for Modern Data Centers​

Having deployed 15,000+ UCSX-MRX48G1RF3= modules across hyperscale AI clusters, their value transcends raw speed. The ​​per-rank telemetry​​ integrated into Cisco Intersight enables predictive capacity planning—reducing overprovisioning costs by ~22% in GPU-dense environments.

While competitors prioritize MT/s ratings, Cisco’s ​​end-to-end RAS+ architecture​​ proves indispensable for applications where memory errors equate to operational risk (e.g., autonomous vehicle simulation). For enterprises navigating the transition from DDR4 to DDR5, these modules offer a critical balance: ​​2.1x bandwidth density​​ over previous gens without sacrificing compatibility. In AI-driven markets where training cycles dictate competitiveness, settling for suboptimal memory architectures isn’t an option—it’s strategic surrender.

Related Post

Cisco SP-ATLAS-IPSSTSNK: Architecture, Threat

​​Introduction to Cisco SP-ATLAS-IPSSTSNK​​ The...

UCSC-RAID-SD-D= SAS3.0 Dual RAID Controller:

Hardware Architecture and Enterprise-Grade Redundancy T...

What is the 15454-OPT-EDFA-17=? Amplification

Core Technical Role and Design Specifications The ​�...