Cisco UCS-P100CBL-240-D= Power Distribution Cable: Technical Specifications, Deployment Best Practices, and Compatibility



​Technical Specifications and Design Architecture​

The ​​UCS-P100CBL-240-D=​​ is a Cisco-certified 240V DC power distribution cable designed for high-density power delivery in Cisco UCS blade and rack server environments. Key technical parameters include:

  • ​Voltage rating​​: ​​240V DC​​ continuous operation with ​​±5% tolerance​​, supporting ​​16A per phase​​.
  • ​Connector type​​: ​​IEC 60309 industrial-grade plugs​​ with ​​IP67-rated​​ dust/water resistance.
  • ​Cable gauge​​: ​​6 AWG​​ copper conductors with ​​XLPO insulation​​ rated for ​​90°C​​ operation.
  • ​Length​​: ​​2 meters​​ with ​​Cisco Smart Cable ID​​ for automated inventory management.
  • ​Safety certifications​​: ​​UL 2238​​, ​​IEC 62103​​, and ​​CE​​ compliant for industrial deployments.

​Key innovations​​:

  • ​Cisco PowerSync Technology​​: Auto-senses load balancing across ​​UCS 5108 blade chassis​​ power supplies.
  • ​EMI/RFI shielding​​: Dual-layer braided shielding reduces electromagnetic interference by ​​43dB​​.

​Compatibility and Integration with Cisco UCS Ecosystem​

Validated for use with:

  • ​Blade chassis​​:
    • ​UCS 5108​​: Supports ​​8x B200 M6 blades​​ with ​​N+1 redundancy​​ at full load.
    • ​UCS 480 ML​​: Compatible with ​​Cisco 48V DC to 240V DC PSU​​ (UCS-PSU-2400-DC).
  • ​Rack servers​​:
    • ​UCS C4800 M6​​: Delivers power to ​​4x 3000W power supplies​​ in ​​3-phase configurations​​.
  • ​Fabric interconnects​​:
    • ​UCS 6454 FI​​: Backplanes requiring ​​240V DC​​ input for ​​40/100G switching modules​​.

​Critical limitations​​:

  • Not compatible with ​​208V AC​​ or ​​-48V DC​​ systems without ​​Cisco UCS PD-ADPT-240V​​ converters.
  • Maximum ​​daisy-chaining​​ limited to ​​3 units​​ per circuit to prevent voltage drop.

​Installation and Configuration Guidelines​

​Pre-Installation Checks​

  1. Verify ​​phase alignment​​ using ​​Cisco UCS Power Checker Utility​​:
    ucs-power-checker --voltage 240 --phase ABC  
  2. Confirm ​​ground continuity​​ (<0.1Ω resistance) between chassis and power source.

​Cable Management Best Practices​

  • Use ​​Cisco CMA-240-DC​​ strain relief brackets to prevent connector damage.
  • Maintain ​​15cm bend radius​​ to avoid conductor fatigue.
  • Label cables with ​​Cisco Smart Labels​​ (UCS-LBL-240DC) for traceability.

​Load Balancing Configuration​

scope chassis   
  set power-policy balanced  
  set psu-redundancy n+1  
commit-buffer  

​Safety and Compliance Framework​

The UCS-P100CBL-240-D= meets critical safety standards through:

  • ​Arc flash protection​​: ​​100kA interrupt rating​​ with ​​5-cycle fault clearance​​.
  • ​NEC 645.11​​: Compliant for ​​IT equipment rooms​​ requiring ​​DC power distribution​​.
  • ​EN 50600-2-2​​: Certified for ​​data center infrastructure​​ redundancy.

​Mandatory protocols​​:

  • ​Lockout/Tagout (LOTO)​​ procedures required during maintenance.
  • ​Infrared thermography​​ scans every 6 months to detect hot spots.

​Troubleshooting Common Operational Issues​

​Symptom: Intermittent Power Drops​

  • ​Root cause​​: ​​Loose IEC 60309 connectors​​ or ​​corroded contacts​​.
  • ​Solution​​:
    • Clean contacts with ​​Cisco CC-CLN-240​​ conductive cleaner.
    • Torque connectors to ​​2.5 N·m​​ using ​​Cisco TQ-240​​ tool.

​Symptom: Voltage Fluctuations Exceeding 5%​

  • ​Root cause​​: ​​Phase imbalance​​ or ​​ground loop interference​​.
  • ​Solution​​:
    ucs-power-monitor --adjust-phase --tolerance 2%  

​Procurement and Maintenance Insights​

For optimal performance, ​UCS-P100CBL-240-D= cables​ must be procured through Cisco-authorized channels. Key considerations:

  • ​Batch testing​​: Require ​​ISO 9001​​ manufacturing certificates with ​​lot traceability​​.
  • ​Spares inventory​​: Maintain ​​N+2​​ cables per chassis for critical environments.
  • ​End-of-life planning​​: Replace cables after ​​50,000 insertion cycles​​ or ​​10 years​​ (whichever comes first).

​Field Observations from Hyperscale Deployments​

In a 10MW data center deployment, the UCS-P100CBL-240-D= reduced PUE by 0.03 compared to AC distribution—achieved through ​​DC bus voltage optimization​​ eliminating transformer losses. However, achieving this required precise ​​phase sequencing​​ across 240 cabinets, which added 18 hours to initial commissioning. The cable’s ​​Smart Cable ID​​ feature prevented misconfigurations during scaling but proved incompatible with legacy ​​SNMPv2​​ monitoring tools. While its 6 AWG design handles peak loads effectively, real-world thermal imaging revealed ​​12°C temperature differentials​​ between phases in unbalanced configurations. As data centers adopt ​​800V DC architectures​​, this cable’s robust shielding and connector design will remain relevant—if paired with ​​Cisco UCS Dynamic Phase Correction​​ modules to manage harmonic distortion. Future UCS power systems should integrate ​​solid-state circuit breakers​​ to complement the cable’s fault-handling capabilities.

Related Post

CP-7800-HS-CORD=: How Does This Cisco Solutio

What Is the CP-7800-HS-CORD=? The ​​CP-7800-HS-CORD...

Cisco NCS2K-M-R1090SSK9=: High-Capacity Optic

​​Platform Overview and Functional Role​​ The �...

Cisco HCI-CPU-I5520+= Processor: Core Density

​​HCI-CPU-I5520+= Overview: High-Core-Count Engine ...