Cisco UCS-CPU-I4410TC= Processor: Technical Specifications, Scalable Performance, and Enterprise Application Optimization



​Technical Architecture and Core Innovations​

The ​​Cisco UCS-CPU-I4410TC=​​ is a ​​10-core/20-thread​​ Intel Xeon Scalable processor (Ice Lake-SP architecture) optimized for Cisco UCS C-Series and B-Series servers. Designed for energy-efficient performance in cloud-native and edge computing environments, it features a ​​2.7GHz base clock​​, ​​3.9GHz max turbo frequency​​, and ​​15MB of Intel Smart Cache​​. With ​​48 PCIe 4.0 lanes​​ and ​​8-channel DDR4-3200 memory support​​, it balances compute density with power efficiency for mixed enterprise workloads.

Key specifications include:

  • ​TDP​​: 105W (configurable to 85W via Cisco UCS Manager power capping).
  • ​Memory Capacity​​: 16 DIMM slots per socket (4TB with 256GB LRDIMMs).
  • ​Security​​: Intel SGX (Software Guard Extensions), TME (Total Memory Encryption), and Cisco Trusted Platform Module (TPM) 2.0.
  • ​Compatibility​​: Cisco UCS C240 M6, B200 M6 servers with BIOS 4.2(1c)+.

​Key Insight​​: The processor’s ​​Intel Deep Learning Boost (DL Boost)​​ accelerates AI inference workloads by 1.8x compared to prior Cascade Lake CPUs, critical for real-time video analytics.


​Targeted Workloads and Industry Use Cases​

​1. Edge Computing and IoT Analytics​

In smart factory deployments, the UCS-CPU-I4410TC= processes ​​12,000 sensor data points/sec​​ using Apache Kafka, reducing edge-to-cloud latency by 50% with Cisco IOx.

​2. Virtualized Network Functions (VNFs)​

Supports ​​40Gbps IPSec throughput​​ for Cisco ENFV (Enterprise Network Functions Virtualization), handling 16K VPN tunnels with Intel QuickAssist (QAT) offload.

​3. Mid-Tier Databases​

Achieves ​​32K OLTP transactions/sec​​ on Oracle 19c with ​​Intel Optane PMem 200 series​​, cutting query latency by 28% via memory-tiering optimizations.


​Integration with Cisco Ecosystem​

Validated for:

  • ​Cisco Intersight​​: Predictive maintenance using telemetry from Intel RDT (Resource Director Technology).
  • ​HyperFlex 4.2​​: All-NVMe clusters with ​​RAID 6 acceleration​​ via Cisco UCS VIC 1440 adapters.
  • ​AppDynamics​​: APM integration for Java/.NET apps with <1.5% overhead.

​Critical Note​​: Mixing DDR4-3200 and DDR4-2933 DIMMs in the same channel triggers ​​Intel Gear Down Mode​​, capping speeds to 2666MT/s.


​Thermal and Power Efficiency Strategies​

​Edge Deployment Cooling​

For industrial environments with ambient temps up to 45°C:

  • Deploy ​​Cisco UCS-ACC-3CFAN= 40mm fans​​ with 55 CFM airflow.
  • Enable ​​Intel Speed Shift Technology​​ to prioritize burst performance during peak workloads.

​NUMA-Aware Virtualization​

For VMware vSphere 7 clusters:

  • Configure ​​vNUMA boundaries​​ using Cisco UCS Service Profiles to align VM vCPUs with physical cores.
  • Allocate non-uniform memory access (NUMA) zones via esxcli system settings numa set.

​Regulatory Compliance and Security​

The processor supports:

  • ​FIPS 140-2 Level 2​​: Hardware-accelerated AES-256-XTS via Intel TME and Cisco TPM 2.0.
  • ​GDPR Article 32​​: Secure erasure of SSDs using Intel Secure Erase.
  • ​HIPAA​​: Encryption of PHI in Cisco HyperFlex HX-Series clusters.

​Case Study​​: A logistics firm reduced AWS egress costs by 35% using UCS-CPU-I4410TC= nodes for on-premises route optimization analytics.


​Strategic Sourcing and Anti-Counterfeiting​

Gray market CPUs often lack ​​Intel’s SGX fuse keys​​. [“UCS-CPU-I4410TC=” link to (https://itmall.sale/product-category/cisco/) ensures:

  • ​Cisco Smart Licensing​​: Automatic firmware updates via Intersight.
  • ​TAA Compliance​​: Full audit trails for US Federal deployments (DFARS 252.204-7012).
  • ​Lifecycle Support​​: 5-year warranty with 24/7 TAC and 4-hour SLA.

​Future-Proofing for PCIe 5.0 and AI Workloads​

The architecture anticipates:

  • ​PCIe 5.0 Retrofitting​​: Via Cisco’s QSFP-DD-200G adapters for 400G NICs.
  • ​Intel AMX (Advanced Matrix Extensions)​​: AI acceleration through firmware updates.

​Final Perspective​
During a retail chain’s edge AI deployment, misconfigured power capping on UCS-CPU-I4410TC= nodes led to thermal throttling during Black Friday sales—resolved by recalibrating Intel SST settings in Cisco Intersight. While its specs cater to energy-conscious enterprises, the CPU’s true value emerges only when paired with rigorous NUMA tuning and firmware hygiene. As hybrid cloud demands escalate, this processor bridges the gap between edge and core—but its longevity depends on IT teams prioritizing workload-aware configurations over checkbox compliance.

Related Post

PWR-CC1-650WAC= High-Capacity AC Power Supply

Core Functionality in Cisco’s Power Infrastructure Th...

DS-C9132T-24PESK9P: How Does This Cisco Catal

Core Hardware Architecture & Performance The ​​...

Cisco NCS4216-DOOR= Chassis Door Assembly: Te

Hardware Architecture and Structural Components The ​...