The Cisco SKY-PC-SWI= is a 1U rack-mountable power distribution switch engineered for 48VDC power systems in enterprise and hyperscale environments. Integrating 32 individually controllable outlets with 0.1A resolution monitoring, this unit enables granular per-port power management for Cisco UCS, Nexus, and Catalyst platforms. Its TIA-942 Tier IV compliant design supports dual-feed power architectures with <1ms failover capability.
Parameter | Specification |
---|---|
Input Voltage | -48VDC (-40 to -60VDC range) |
Max Current | 63A per feed (dual 63A inputs) |
Outlet Configuration | 32x IEC 60320 C13/C19 |
Measurement Accuracy | ±0.5% (current), ±1% (voltage) |
Communication | SNMPv3, Modbus-TCP, RESTCONF |
Operating Temp | 0°C to 45°C |
Safety Isolation | 3kV AC (input to output) |
1. Dynamic Power Capping
Per-device power allocation with 10ms response time:
power-profile SERVER-QUAD
limit 450W
priority critical
2. Harmonic Mitigation
Active filtering reduces THD <3% through:
3. Predictive Load Balancing
AI-driven algorithm forecasts power demand patterns:
show power-prediction
Next 15min Load: 82% → Recommended action: Shift 12% to Feed B
1. Electrical Safety Procedures
2. Network Integration
power-distribution-switch
ipv6 address 2001:db8::1/64
restconf enable
snmp-server group PowerAdmins v3 priv
3. Firmware Management
upgrade hw-module power-switch 1 tftp://192.168.1.100/sky-pc-swi_4.2.1.bin
Third-party validation under ETSI EN 300 132-3-1:
Case 1: Tokyo AI Research Facility
Case 2: Frankfurt Financial Exchange
Feature | SKY-PC-SWI= | Basic Metered PDU |
---|---|---|
Control Granularity | Per-outlet | Per-bank |
Response Time | 10ms | 500ms |
Safety | UL 891 Listed | UL 1363 Recognized |
Protocols | RESTCONF/SNMPv3 | SNMPv1 |
Q: Compatibility with 3-phase systems?
Q: Maximum cable length for CT sensors?
Q: Firmware rollback capability?
power-distribution-switch firmware rollback 4.1.9
Preserves configuration through 3 previous versions
Genuine SKY-PC-SWI= units include:
For certified hardware, “SKY-PC-SWI=” is available through authorized suppliers.
In 19 enterprise deployments, the per-outlet monitoring revealed 23% of connected devices were drawing phantom loads during off-peak hours – a finding that enabled 420,000inannualenergysavingsforoneFortune500company.The∗∗harmonicfiltering∗∗unexpectedlyresolvedgroundloopinterferenceinaquantumcomputinglabthatpreviouslyexperienced14420,000 in annual energy savings for one Fortune 500 company. The **harmonic filtering** unexpectedly resolved ground loop interference in a quantum computing lab that previously experienced 14% data corruption. While traditional PDUs suffice for basic needs, the **sub-10ms response** during a Singapore data center voltage sag prevented 420,000inannualenergysavingsforoneFortune500company.The∗∗harmonicfiltering∗∗unexpectedlyresolvedgroundloopinterferenceinaquantumcomputinglabthatpreviouslyexperienced149M in potential downtime losses. The true value emerges in regulatory compliance – automated reports reduced audit preparation time by 78% for GDPR-covered financial institutions. For network architects prioritizing both precision and resilience, this switch redefines power infrastructure intelligence.