Cisco PWR-CH1-1100WAC=: High-Capacity 1100W AC Power Supply for Hyperscale and Mission-Critical Networks



​Product Architecture and Design Philosophy​

The ​​Cisco PWR-CH1-1100WAC=​​ is a ​​1100-watt AC power supply​​ engineered for ​​Cisco Nexus 9500 Series switches​​, ​​UCS C480 ML servers​​, and ​​high-density AI/ML infrastructure​​. Designed to address the escalating power demands of hyperscale data centers and enterprise core networks, it integrates advanced thermal management, modular redundancy, and energy efficiency. Key innovations include:

  • ​Dual-Mode Efficiency​​: ​​94% efficiency​​ at 50% load (80 Plus Platinum certified), reducing ​​PUE (Power Usage Effectiveness)​​ by ​​0.15​​ in liquid-cooled racks.
  • ​Hot-Swap Redundancy​​: Supports ​​N+N configurations​​ with ​​≤2 ms failover​​, critical for ​​five-nines (99.999%) uptime​​ SLAs.
  • ​Thermal Resilience​​: ​​Triple ball-bearing fans​​ with ​​IP55-rated dust filters​​, maintaining ​​≤70°C internal temps​​ in ​​ASHRAE A4​​ (55°C ambient) environments.

This PSU is validated for use with ​​Cisco 800G optics​​ and integrates with ​​Cisco Intersight​​ for predictive health analytics, enabling proactive maintenance in distributed architectures.


​Technical Specifications and Compliance​

Cisco’s 2024 Power Systems Validation Report confirms:

  • ​Input Range​​: ​​200–277V AC​​ (50/60 Hz), ​​±10% tolerance​​ with ​​active power factor correction (PFC ≥0.99)​​.
  • ​Output​​: ​​12V DC ±1%​​, ​​91.6A continuous current​​ (IEC 62368-1).
  • ​Protection Mechanisms​​:
    • ​Over-Temperature Protection​​: Triggers at ​​90°C​​ (EN 60950-1).
    • ​Inrush Current Limiting​​: ​​≤40A​​ peak (IEC 61000-3-3).
  • ​Certifications​​: ​​UL 60950-1​​, ​​NEBS Level 3​​, ​​CE Mark​​, ​​RoHS 3​​.
  • ​Environmental Compliance​​:
    • Operating Temperature: ​​-40°C to 70°C​​ (IEC 60068-2-1).
    • Humidity: ​​5–95% non-condensing​​ (IEC 60068-2-78).

Lab tests achieved ​​MTBF of 2.4 million hours​​ under ​​70°C stress​​ and ​​99.999% uptime​​ during ​​90-day load cycling​​.


​Key Use Cases and Deployment Scenarios​

​1. AI/ML Training Clusters​

A North American hyperscaler deployed 300 PSUs in ​​Cisco UCS C480 ML servers​​ with ​​NVIDIA H100 GPUs​​, sustaining ​​≤0.3% voltage deviation​​ during ​​50,000A transient loads​​ in large language model (LLM) training.

​2. Financial Trading Networks​

A London-based stock exchange used the PSU in ​​Cisco Nexus 9636C-RX​​ switches to ensure ​​microsecond-latency stability​​ for algorithmic trading, surviving ​​16G mechanical shocks​​ during facility construction.

​3. Telecom 5G Core Virtualization​

An Asian carrier integrated the PSU into ​​Cisco NCS 5700 routers​​ for ​​5G Core UPF workloads​​, achieving ​​99.999% availability​​ during monsoon-season grid fluctuations.


​Addressing Critical Customer Concerns​

​Q: Can it replace legacy 2200W PSUs in Cisco Nexus 9504 chassis?​

Yes, but requires ​​Cisco NX-OS 10.3.3+​​ to enable ​​Adaptive Phase Balancing​​ for optimal load distribution.

​Q: How to manage harmonic distortion in shared grids?​

The ​​Active Harmonic Cancellation (AHC)​​ circuit maintains ​​THD ≤2.5%​​ under ​​40–100% load​​ (per EN 61000-3-2).

​Q: What maintenance ensures fan reliability?​

  • ​Monthly​​: Clean filters with ​​Cisco CAB-CLN-IP55​​ kits.
  • ​Annually​​: Replace fans using ​​Cisco FRU-PSU-FAN1100=​​ modules.

​Installation and Optimization Best Practices​

  1. ​Phase Balancing​​:
    • Distribute PSUs across ​​three-phase circuits​​ to limit ​​neutral current imbalance​​ to ​​≤2%​​ (IEEE 519).
  2. ​Grounding​​:
    • Use ​​4 AWG grounding cables​​ (≤0.02 Ω resistance) bonded to ​​UL 467 busbars​​.
  3. ​Firmware Updates​​:
    install module power-supply firmware 11.2.1a  

    Execute in ​​Cisco NX-OS​​ to enable ​​Dynamic Voltage Scaling (DVS)​​ for AI workloads.

For enterprises migrating from ​​AC/DC hybrid systems​​, Cisco offers ​​trade-in rebates covering 25% of costs​​ under its Hyperscale Efficiency Program.


​Why Hyperscalers and Enterprises Standardize on This PSU​

  • ​Total Cost of Ownership​​: ​​$2,800 per unit​​ (TCO over 10 years), ​​40% lower​​ than HPE/Delta equivalents due to ​​10-year warranty​​ and ​​zero field failures​​ in Cisco-validated setups.
  • ​Compliance​​: Exceeds ​​ANSI/TIA-942 Tier IV​​ and ​​EU Code of Conduct 2025​​ for data center sustainability.
  • ​Future-Proofing​​: Supports ​​Cisco Silicon One G200​​ ASICs for 800G-ZR coherent optics.

For procurement, visit the Cisco PWR-CH1-1100WAC= product page at ITMall.sale.


​Operational Insights from Extreme Environments​

Two paradoxical truths emerge from global deployments:

  1. ​Efficiency Is a Journey, Not a Metric​​: A Dutch hyperscaler reduced ​​cooling costs by 22%​​ not by chasing higher efficiency percentages, but by using ​​Intersight​​ to align PSU fan curves with external weather patterns—proving contextual intelligence outweighs static specs.
  2. ​Redundancy Requires Imperfection​​: A Brazilian bank’s ​​N+N setup​​ failed during a blackout—not due to PSU faults, but because backup circuits were never load-tested. The fix? ​​Monthly “chaos engineering” drills​​—because even flawless hardware needs flawed humans to stay reliable.

In an era obsessed with AI and terabits, the PWR-CH1-1100WAC= whispers a sobering truth: ​​the cloud’s mightiest algorithms still bow to the laws of physics​​. For engineers, it’s a reminder that while innovation scales exponentially, power—reliable, unwavering, and unglamorous—remains the foundation. After all, in the data center’s cathedral, the PSU isn’t just a component; it’s the altar where electrons convert ambition into reality.

Related Post

Cisco QDD400GZR-15-BUN 400G Coherent Transcei

​​Product Overview and Core Functionality​​ The...

UCS-SDC960SA1V= Enterprise SATA SSD with Trip

Core Hardware Architecture & NAND Innovation The �...

ASR-9922-DC: Why Is It Critical for High-Dens

What Is the ASR-9922-DC? The ​​ASR-9922-DC​​ is...