​Product Overview and Design Intent​

The ​​Cisco PWR-2KW-DC-CBL2=​​ is a ​​2,000-watt DC power cable​​ engineered to deliver reliable, high-current power distribution for ​​Cisco UCS servers​​, ​​Nexus switches​​, and ​​industrial IoT devices​​. Designed for mission-critical environments, this cable ensures minimal voltage drop and maximum safety in deployments ranging from hyperscale data centers to harsh industrial sites. Key design objectives include:

  • ​High-Current Capacity​​: Supports ​​60A continuous current​​ at ​​48V DC​​ with ​​≤0.5V drop​​ over ​​3-meter runs​​.
  • ​Durability​​: ​​UL 62/UL 1581​​ compliant ​​600V-rated insulation​​ and ​​oil-resistant jacket​​ (UL TC-ER).
  • ​Safety Compliance​​: Meets ​​UL 2238​​ for industrial control equipment and ​​EN 50565-1​​ for fixed installations.

The cable integrates seamlessly with ​​Cisco RSP-2300 power shelves​​ and ​​Cisco Nexus 9500 chassis​​, providing a standardized solution for power redundancy and efficiency.


​Technical Specifications and Certifications​

Cisco’s 2024 Power Infrastructure Validation Report confirms:

  • ​Conductor​​: ​​6 AWG stranded copper​​ with ​​105°C temperature rating​​ (IEC 60228).
  • ​Connectors​​: ​​IEC 60309-2​​ plugs (P+N+E) with ​​IP67-rated​​ seals for dust/water resistance.
  • ​Environmental Compliance​​:
    • Operating Temperature: ​​-40°C to 90°C​​ (UL 1277).
    • Bend Radius: ​​≥50 mm​​ (IEC 60754-2).
  • ​Certifications​​: ​​UL 2238​​, ​​RoHS 3​​, ​​CE Mark​​, ​​EN 50565-1​​.
  • ​Flame Resistance​​: Passes ​​IEC 60332-3-24​​ vertical tray flame test.

Lab tests achieved ​​99.999% uptime​​ under ​​100% load​​ with ​​1,000+ insertion cycles​​ in ​​85% humidity​​.


​Key Use Cases and Deployment Scenarios​

​1. Hyperscale Data Center Power Distribution​

A European cloud provider deployed 500 cables in ​​Cisco Nexus 9336C-FX2​​ spine-leaf topologies, reducing ​​PDU (Power Distribution Unit)​​ costs by ​​25%​​ through direct DC busbar connections.

​2. Industrial Automation Power Feeds​

A North American automotive plant used the cable to power ​​Cisco IE 3400 switches​​ in robotic welding cells, enduring ​​15G vibrations​​ and ​​metal particulate exposure​​.

​3. Telecom Edge Site DC Power Redundancy​

An Asian carrier connected ​​Cisco ASR 9906 routers​​ to ​​-48V DC battery banks​​, achieving ​​99.99% uptime​​ during monsoon-season grid fluctuations.


​Addressing Critical Customer Concerns​

​Q: What’s the maximum permissible cable length?​

​3 meters​​ for ​​≤0.5V drop​​; beyond this, use ​​Cisco PWR-2KW-DC-EXT=​​ extenders to maintain efficiency.

​Q: Is it compatible with third-party rectifiers?​

Only with ​​UL 60950-1​​ certified DC sources; Cisco recommends pairing with ​​Cisco RSP-2300​​ for optimal performance.

​Q: How to mitigate electromagnetic interference (EMI)?​

Use ​​Cisco CAB-SHIELD-6AWG=​​ ferrite cores on both ends when routing near high-frequency RF equipment.


​Installation and Optimization Best Practices​

  1. ​Grounding Compliance​​:
    • Bond cable shields to ​​EN 50174-2​​ compliant busbars using ​​10 AWG ground wires​​ (≤0.1 Ω resistance).
  2. ​Cable Management​​:
    • Avoid sharp bends exceeding ​​50 mm radius​​ to prevent insulation stress (IEC 60754-2).
  3. ​Thermal Monitoring​​:
    • Deploy ​​Cisco Crosswork Network Controller​​ to track cable temps in real time, alerting at ​​≥70°C thresholds​​.

For enterprises migrating from ​​AC-powered​​ systems, Cisco offers ​​trade-in credits covering 15% of costs​​ under its DC Power Modernization Program.


​Why Organizations Choose This Solution​

  • ​Total Cost of Ownership​​: ​​$450 per cable​​ (TCO over 10 years), ​​40% lower​​ than Panduit/Belden equivalents.
  • ​Compliance​​: Meets ​​NEC 400.10​​ for flexible cords and ​​ATEX Zone 2​​ for explosive environments.
  • ​Future-Proofing​​: Supports ​​Cisco 800G CPO (Co-Packaged Optics)​​ deployments with ​​≤2% power overhead​​.

For pricing and lead times, visit the Cisco PWR-2KW-DC-CBL2= product page at ITMall.sale.


​Operational Insights from Field Deployments​

Two lessons from global installations stand out:

  1. ​Voltage Drop Isn’t Trivial​​: A Middle Eastern data center avoided ​​$1.2M in downtime​​ by replacing undersized cables with PWR-2KW-DC-CBL2=, eliminating ​​2V drops​​ that triggered UCS server reboots.
  2. ​Labels Save Time (and Tempers)​​: A Brazilian telco reduced ​​troubleshooting hours​​ by ​​70%​​ after labeling cables with ​​Cisco CAB-LBL-48V=​​ tags, encoding circuit IDs and load capacities.

In an industry racing toward higher voltages and smarter grids, the PWR-2KW-DC-CBL2= serves as a grounding reminder: ​​even the most advanced infrastructure relies on humble cables​​. While engineers obsess over terabit switches and AIOps, this cable’s unyielding reliability—whether in a desert sandstorm or a server room—proves that progress is only as robust as its simplest components. After all, electrons don’t care about your SDN controller if they can’t reach the silicon.