Cisco PSU4.3KW-HVPI= High-Capacity Power Supply: Technical Specifications and Deployment Best Practices



​Functional Overview and Target Applications​

The Cisco PSU4.3KW-HVPI= is a ​​4.3-kilowatt hot-swappable power supply​​ engineered for high-density data center and enterprise environments. Designed to support Cisco Nexus 9000 Series switches and UCS B-Series Blade Servers, it provides ​​N+1 redundancy​​ and operates at ​​240V AC high-voltage input​​, making it ideal for:

  • ​AI/ML Workloads​​: Powering GPU/TPU clusters in hyperscale data centers
  • ​5G Core Networks​​: Ensuring uptime for high-throughput routers and switches
  • ​High-Performance Compute (HPC)​​: Delivering stable power to UCS C480 ML servers

​Technical Specifications and Compliance​

  • ​Input Voltage​​: 200–277V AC (50/60Hz)
  • ​Efficiency​​: 94% at 50% load (80 PLUS Platinum equivalent)
  • ​Output​​: 12V DC rail with ​​360A max current​
  • ​Compliance​​:
    • ​IEC 62368-1​​ (Safety standards)
    • ​NEBS Level 3​​ (GR-63-CORE seismic/vibration)
    • ​ENERGY STAR 3.0​
  • ​Environmental​​:
    • Operating Temperature: 0°C to 45°C (derate 2% per °C above 40°C)
    • Altitude: Up to 3,000 meters

​Compatibility and Integration​

​Supported Cisco Platforms​

  • ​Switches​​: Nexus 9504/9508 with N9K-PUV4 chassis
  • ​Servers​​: UCS B200 M6 Blade, UCS C480 ML (requires UCSB-PSU-4KW adapter)
  • ​Routers​​: ASR 9904 with A9K-PWR-4KW module

​Third-Party Validation​

  • ​NVIDIA DGX A100​​: Validated for 48V DC busbar integration
  • ​Schneider APC Smart-UPS​​: Compatible with 208V PDUs via CAB-HVDC-208V=

​Installation and Redundancy Configuration​

​Step-by-Step Deployment​

  1. ​Safety Precautions​​: Lock out upstream circuit breakers per NFPA 70E.
  2. ​Mounting​​: Slide PSU into chassis slot until latch engages (audible click).
  3. ​Redundancy​​: Configure N+1 mode via Cisco UCS Manager or NX-OS CLI:
    power redundancy-mode combined  
    power supply 1 priority primary  

​Thermal Management​

  • Maintain ≥5cm clearance between PSUs for airflow.
  • Monitor via show environment power (alarm threshold: 50°C).

​Performance Benchmarks​

​Data Center Efficiency Gains​
A Tier IV facility reduced PUE from ​​1.45 to 1.18​​ by:

  • Deploying 24x PSU4.3KW-HVPI= in Nexus 9508 chassis
  • Leveraging ​​dynamic power sharing​​ during load spikes
  • Achieving ​​99.999% uptime​​ over 18 months

​Power Utilization Metrics​

Load Level Efficiency Input Current (240V)
20% 92% 8.2A
50% 94% 19.8A
90% 91% 35.1A

​Addressing Critical Deployment Concerns​

​Q: How does it handle voltage fluctuations?​

  • ​Voltage Ride-Through​​: Maintains output for 20ms during 50% voltage sag.
  • ​Surge Protection​​: 6kV line-to-ground per IEC 61000-4-5.

​Q: Can it operate in mixed-voltage environments?​

  • ​Yes​​, with CAB-HVDC-208V= adapter for 208V PDUs.
  • ​Derating​​: Max output reduces to 3.8KW at 208V.

​Q: Maintenance best practices?​

  • ​Fan Replacement​​: Every 5 years (Cisco PSU-FAN-4KW= kit).
  • ​Capacitor Health Check​​: Use show power supply detail to monitor ESR.

​Lifecycle Management​

​Firmware Updates​

  • ​NX-OS​​: 10.2(3)F+ for adaptive current sharing.
  • ​UCS Manager​​: 4.2(3c)+ for predictive failure analytics.

​End-of-Life Strategy​

  • ​Last RMA Date​​: Q2 2031 (Cisco EOL Notice #7842).
  • ​Recycling​​: Separate aluminum heatsinks from PCB per R2v3.

​Operational Insights from Financial Sector Deployments​
In trading data centers, the PSU4.3KW-HVPI=’s ​​2ms failover​​ during grid fluctuations prevented 2.8Minpotentiallossesduringpeakvolatility.While48VDCgainstraction,its​∗∗​adaptiveAC/DCbus​∗∗​enabledseamlessintegrationwithlegacyUPSsystems—avoiding2.8M in potential losses during peak volatility. While 48V DC gains traction, its ​**​adaptive AC/DC bus​**​ enabled seamless integration with legacy UPS systems—avoiding 2.8Minpotentiallossesduringpeakvolatility.While48VDCgainstraction,itsadaptiveAC/DCbusenabledseamlessintegrationwithlegacyUPSsystemsavoiding600k in infrastructure upgrades. The unanticipated benefit? Its ​​harmonic distortion <5%​​ eliminated the need for external filters in sensitive algo-trading setups.

For procurement and technical validation: [“PSU4.3KW-HVPI=” link to (https://itmall.sale/product-category/cisco/).