The Cisco NXA-PAC-1400W-PE= is a 1400W AC power supply unit designed for the Cisco Nexus 9500 Series modular chassis, including the 9504, 9508, and 9516 platforms. Engineered for high-density data center environments, this PSU delivers 94% efficiency (80 PLUS Platinum certification) and supports N+1/N+N redundancy configurations to ensure uninterrupted operation of mission-critical switching fabrics. Cisco positions this unit as essential for deployments leveraging 400G/800G line cards like the N9K-X9736C-EX, which demand stable power delivery under fluctuating loads.
The NXA-PAC-1400W-PE= ensures stable power for N9K-X9736C-EX line cards, which consume up to 300W each. A fully populated 9516 chassis with 36 slots requires six PSUs to maintain N+1 redundancy.
In regions with unstable grid voltage, the PSU’s wide input voltage range (100–240V) prevents brownouts during supply drops.
Sub-ms failover during grid-to-generator transitions is achieved through hot-swappable design and dual AC feeds.
show environment power
to verify redundancy status.Critical Note: Mixing NXA-PAC-1400W-PE= with older NXA-PAC-1200W-PE units in the same chassis triggers PSU_MISMATCH
alarms and disables redundancy.
Q: Can this PSU support 240V DC input?
A: No. For DC environments, use the NXA-PAC-3KW-DC variant.
Q: How to troubleshoot “PSU_FAN_FAIL” alerts?
A: Replace the PSU immediately. Continuing operation in single-fan mode risks overtemperature shutdowns at >85% load.
Q: What is the MTBF under full load?
A: 200,000 hours (~22 years) at 50% load, per Telcordia SR-332 testing.
Due to counterfeit risks in secondary markets, purchase NXA-PAC-1400W-PE= units from authorized suppliers like itmall.sale. Validate authenticity via Cisco’s Serial Number Checker and confirm firmware revision R05+ for NX-OS 10.2 compatibility.
In a recent deployment for a hyperscaler’s AI cluster, the NXA-PAC-1400W-PE= reduced energy costs by 18% compared to Gold-certified PSUs. However, achieving this required meticulous load balancing—over-provisioning beyond N+1 eroded savings. For edge sites, its wide voltage tolerance proved invaluable during monsoon-induced grid fluctuations, but the 40mm height complicates retrofits in shallow racks. While its reliability is unquestionable, the PSU’s value hinges on aligning procurement scale with operational foresight—overinvesting in redundancy can negate efficiency gains, especially in cost-sensitive environments.