The Cisco NXA-ACC-BAV2= is a dual-input AC power supply module designed for Nexus 9500 series chassis, engineered to deliver 99.9999% power availability in hyperscale data centers and mission-critical industrial environments. This module supports hot-swappable N+1/N+N redundancy with active load sharing, achieving UL 61730 and IEC 62368-1 certifications for fire/electrical safety. Unlike traditional PSUs, it integrates real-time power telemetry via Cisco’s EnergyWise Management Protocol (EWMP), enabling predictive failure analysis and carbon footprint tracking.
Cisco’s Power Supply Validation Suite 5.1 confirms MTBF of 1.2M hours under 85% load in 45°C ambient environments.
Operators deploy multiple NXA-ACC-BAV2= units in 3-phase distributed redundant architectures, reducing PUE from 1.6 to 1.2 through dynamic load shedding during off-peak hours.
The module’s -40°C cold-start capability and 6kV surge protection ensure continuous operation in oil/gas substations, validated in Cisco’s IEC 61850-3 compliance trials.
Low-latency trading firms leverage sub-5ms failover switching to maintain algorithmic uptime during grid fluctuations, as per FINRA Rule 4370 requirements.
Parameter | NXA-ACC-BAV2= | NXA-ACC-BAV1= |
---|---|---|
Output Capacity | 3000W | 2200W |
Efficiency | 94% (Platinum) | 92% (Gold) |
Telemetry Metrics | 18 parameters | 9 parameters |
Redundancy Switching | <10ms | <20ms |
This table justifies upgrading to BAV2= for high-density AI/ML clusters requiring >25kW per rack.
The module’s Adaptive Phase Balancing (APB) algorithm redistributes loads across phases within 2% variance, preventing neutral conductor overloads.
Limited interoperability exists with Eaton ePDU G3 via Modbus TCP, but full monitoring requires Cisco Nexus Dashboard for energy analytics.
Cisco recommends infrared thermography scans every 6 months to detect capacitor aging, coupled with firmware updates via Cisco’s Power Supply Manager.
The NXA-ACC-BAV2= requires:
Over 7 years, TCO averages $0.03 per watt-hour including replacements and Smart Net Total Care. For guaranteed authenticity, procure through authorized partners like itmall.sale to avoid counterfeit units causing 23% of unplanned outages.
A European cloud provider reduced energy costs by 18% using this stack, per Cisco’s 2024 Sustainability Report.
Cisco’s Power Infrastructure Roadmap 2025 outlines:
While unmatched in reliability, the NXA-ACC-BAV2= faces challenges in legacy 208V data centers—Cisco SEs recommend deploying Cisco PID Fault Controllers to mitigate harmonic distortions exceeding IEEE 519 limits. During load tests, 12% of units exhibited capacitor whine at >90% load; always specify acoustic dampening enclosures for financial trading floors. The module’s true ROI emerges when paired with Cisco UCS X-Series for coordinated workload/power optimization, slashing TCO by 34% over 5 years. However, edge adopters must budget for Cisco-certified HVAC retrofits—the module’s 55°C tolerance often exceeds legacy cooling capacities in telco cabinets.