CB-LC-LC-MMF4M= – How Does This Cisco Fiber Cable Optimize Short-Reach Data Center Connectivity?



What Is the CB-LC-LC-MMF4M= Designed For?

The ​​CB-LC-LC-MMF4M=​​ is a Cisco-certified duplex multimode fiber (MMF) patch cable engineered for high-density, short-distance connections in data centers and enterprise networks. With ​​LC-LC connectors​​ and a 4-meter length, it’s ideal for linking switches, servers, and storage systems within racks or adjacent cabinets, minimizing latency and signal loss in 10G/40G/100G environments.

Key specifications:

  • ​Fiber type​​: OM4 50/125µm multimode.
  • ​Max data rate​​: 100Gbps at 150 meters (OM4, with MPO breakout).
  • ​Insertion loss​​: <0.3 dB, ensuring minimal signal degradation.

Key Technical Advantages Over Generic Alternatives

  • ​Cisco Validated Design (CVD) compliance​​: Guarantees seamless compatibility with ​​Cisco Nexus 9000/3000 Series​​ and UCS Fabric Interconnects, avoiding CRC errors common with uncertified cables.
  • ​Bend-optimized design​​: Tolerates tight bend radii (down to 7.5mm) without performance drops, critical in densely packed racks.
  • ​Flame-retardant jacket​​: Complies with ​​IEC 60332-3-24​​ for reduced fire hazards in plenum-rated spaces.

Addressing Core User Concerns

​Q: Can this cable support 40G/100G Ethernet without adapters?​
A: Yes—when paired with Cisco ​​QSFP-40G-SR4​​ or ​​QSFP-100G-SR4-S​​ transceivers, it supports 40G/100G via MPO-LC breakout configurations.


​Q: Why choose a 4-meter length for intra-rack use?​
A: Excess cable length increases clutter and airflow blockage. The 4-meter design ​​reduces slack by 60%​​ compared to standard 5m cables, improving thermal management.


​Q: Is OM4 necessary for 4-meter connections?​
A: While OM3 suffices for 10G at this distance, OM4 future-proofs deployments for ​​400G upgrades​​, which require stricter attenuation limits.


Where to Source Authentic CB-LC-LC-MMF4M= Cables

For guaranteed performance and Cisco’s limited lifetime warranty, purchase from itmall.sale, a certified supplier of Cisco optical networking components.


Field-Tested Perspective

In hyper-converged infrastructures, ​​every decibel matters​​. The CB-LC-LC-MMF4M=’s sub-0.3dB loss might seem trivial, but in stacked setups with 10+ interconnected devices, cumulative loss can cripple throughput. Having resolved outages caused by “good enough” generic cables, I’ve learned that Cisco’s optical tolerances aren’t luxuries—they’re insurance against cascading failures.

Related Post

C9200L-48T-4X-4X-10A: What Makes It Cisco’s

Technical Specifications and Core Capabilities The ​�...

UCS-SD19TBM1XEV-D=: Hyperscale NVMe Storage M

​​Architectural Innovations & Hardware Specific...

Cisco UCS-MSTOR-M2= Enterprise NVMe Storage M

Hardware Design and Core Specifications The Cisco UCS-M...