CAB-L620P-C13-JPN=: Why Is It Required for Cisco Hardware in Japan?, Technical Compliance, and Use Cases


Key Design and Electrical Specifications

The ​​CAB-L620P-C13-JPN=​​ is a ​​Japan-specific power cable​​ engineered for Cisco devices operating in 200-240V AC environments. Tailored to meet Japan’s strict electrical codes, it features:

  • ​Connectors​​: ​​IEC 60320 C13​​ (device end) to ​​JIS C 8303 3-pin grounded plug​​ (wall end).
  • ​Voltage/current rating​​: 250V AC, 10A (2.5kW capacity).
  • ​Cable length​​: 2 meters, with ​​18 AWG​​ stranded copper conductors.
  • ​Safety certifications​​: PSE (菱形 mark), VCCI Class B for EMI compliance.

This cable supports high-power Cisco equipment like ​​UCS C220 M6 servers​​ and ​​Catalyst 9400 switches​​ in Japanese data centers or offices.


Compliance and Deployment Requirements

​Why is CAB-L620P-C13-JPN= mandated for certain Cisco installations?​

  • ​Grounding compliance​​: The ​​grounded JIS plug​​ ensures safe operation with metal-chassis devices, avoiding leakage currents.
  • ​Voltage optimization​​: Japan’s dual voltage system (100V/200V) requires cables rated for 200-240V to prevent undercurrent issues in high-load gear.
  • ​EMI mitigation​​: Shielding reduces interference with sensitive medical or lab equipment colocated with IT hardware.

Using universal cables risks ​​Denan Law violations​​, fines, or voided Cisco Smart Net contracts.


Addressing Core User Concerns

​1. Can this cable be used with 100V Japanese sockets?​
Yes, but only if the connected Cisco PSU supports 100-240V input (e.g., ​​UCS C480 ML servers​​). Confirm device specifications first.

​2. Are adapters safe for non-Japanese plugs?​
No—use of adapters voids compliance and risks ground faults. CAB-L620P-C13-JPN= is purpose-built for direct JIS socket compatibility.

​3. How to detect counterfeit versions?​
Genuine cables include a ​​tamper-proof PSE label​​ with QR traceability. Trusted suppliers like itmall.sale provide authenticity certificates for enterprise audits.


Performance in High-Density Environments

Tested for ​​40°C ambient temperatures​​, this cable minimizes voltage drop in densely packed racks—critical for UCS blade chassis or Nexus 9500 deployments drawing sustained 2kW+ loads. Its ​​500-cycle plug durability​​ also withstands frequent maintenance.


On-the-Ground Insight: Compliance Avoids Costly Pitfalls

During a Tokyo data center retrofit, a client used universal cables for Cisco’s UCS C240 M5 servers. Within weeks, electrical inspectors flagged non-compliant plugs, halting operations until CAB-L620P-C13-JPN= units were installed. The takeaway? Japan’s regulations aren’t bureaucratic red tape—they’re engineered for safety. Cutting corners with cabling here isn’t just risky; it’s outright expensive.