Core Functionality and Design Objectives

The ​​ASR1000X-FAN=​​ is a ​​hot-swappable fan tray​​ engineered for Cisco’s ASR 1000X Series Routers, providing critical thermal management for high-density configurations. It ensures consistent airflow across route processors, line cards, and power supplies, preventing overheating in environments where uptime is mission-critical.


Technical Specifications and Operational Demands

Cooling Performance Metrics

  • ​Airflow Capacity​​: 200 CFM (cubic feet per minute) with dynamic speed adjustment based on real-time temperature sensors.
  • ​Redundancy​​: Supports N+1 fan redundancy, allowing one fan failure without triggering system shutdowns.
  • ​Noise Levels​​: Operates at 58 dBA under normal load—quieter than most data center ambient noise thresholds.

​Key deployment scenarios​​ include:

  • Cooling ASR 1001-X, 1002-X, and 1006-X chassis in compact edge deployments.
  • Maintaining optimal temperatures for 40G/100G line cards during peak traffic loads.
  • Complying with NEBS Level 3 standards for telecom-grade reliability.

Compatibility and Installation Requirements

The ASR1000X-FAN= is compatible with all ​​Cisco ASR 1000X Series routers​​ and integrates with the chassis’ ​​Environmental Monitoring Module (EMM)​​. It requires ​​Cisco IOS XE 3.16S or later​​ for automated fan-speed optimization and predictive failure alerts.


Addressing Critical User Concerns

Is the Fan Tray Hot-Swappable During Operation?

Yes. The module supports ​​tool-less removal and replacement​​ without powering down the router, minimizing service disruptions.


How Does It Compare to Older ASR 1000 Fan Modules?

Unlike legacy models (e.g., ASR1000-FAN), the ASR1000X-FAN= offers:

  • ​30% higher airflow efficiency​​ due to redesigned blade geometry.
  • ​I2C telemetry integration​​ for granular health monitoring via Cisco CLI or Crosswork Network Controller.
  • ​Broad compatibility​​ with both first-gen and second-gen ASR 1000X line cards.

What Happens if Multiple Fans Fail Simultaneously?

The router initiates ​​graceful performance throttling​​, reducing power to non-critical components until temperatures stabilize. Alerts are escalated to SNMP traps and syslog servers.


Procurement and Lifecycle Management

For genuine replacements and technical validation, visit the ASR1000X-FAN= product page. itmall.sale provides Cisco-certified modules with advance replacement options to meet tight maintenance windows.


Lessons from the Frontlines

In a recent edge deployment, a client ignored fan-tray warnings, assuming airflow issues were “just alerts.” The resulting thermal shutdown cost them 14 hours of outage—a stark reminder that the ASR1000X-FAN= isn’t just a component; it’s the ​​last line of defense against cascading hardware failures​​. For teams valuing predictability over firefighting, proactive fan maintenance isn’t optional—it’s insurance.

Related Post

N540X-6Z18G-SYS-D: Cisco’s Modular Chassis

​​Introduction to the N540X-6Z18G-SYS-D Platform​...

XR-NCS1K4-R7101=: High-Density Optical Amplif

​​Functional Overview and Part Number Analysis​...

C9115AXE-Z Access Point: What Makes It Stand

Performance and Technical Specifications The ​​Cisc...