CAB-AC-10A-JPN2=: How Does It Solve Japan’s Unique Cisco Power Challenges?



Core Application of CAB-AC-10A-JPN2=

The ​​CAB-AC-10A-JPN2=​​ is a Cisco-certified 10A/125V AC power cable engineered for Japan’s 50Hz/60Hz dual-frequency grid. Designed with a ​​JIS C 8303-compliant Type A plug​​, it ensures safe connectivity between Cisco devices and Japan’s polarized outlets, which differ from global IEC standards.


Key Technical Specifications

  • ​Voltage Tolerance​​: Handles 90V–140V fluctuations common in Tokyo’s aging power infrastructure.
  • ​Connector Design​​: Angled ​​C19 receptacle​​ prevents accidental disconnection in earthquake-prone regions.
  • ​Safety Certifications​​: Meets ​​PSE Mark​​ and ​​Cisco’s 100,000-flex-cycle durability​​ requirements for high-traffic data centers.

Compatibility and Deployment Scenarios

​Supported Hardware​​:

  • ​Cisco UCS C220 M7 servers​​ running at 950W PSU load
  • ​Nexus 3164Q switches​​ in edge colocation facilities using 100V/200V step-down transformers

​Common Misconfigurations​​:

  • Using non-JPN2 cables with ​​Cisco ASR 1001-HX routers​​ triggers ground loop errors due to mismatched pin lengths.
  • Generic cables lack the ​​3.0mm² conductor gauge​​ needed for sustained 10A draw on UCS B-series blades.

Safety and Regulatory Requirements

The CAB-AC-10A-JPN2= incorporates ​​double-insulated 105°C-rated sheathing​​ to withstand Osaka’s 85% average humidity. Its ​​15mm strain relief collar​​ exceeds JIS C 8303 bending standards, critical for cable management in compact NTT East server racks.


Sourcing Authentic CAB-AC-10A-JPN2= Units

Non-compliant replicas cause 23% of power-related faults in Japanese enterprises. For guaranteed adherence to local laws:
Procure certified CAB-AC-10A-JPN2= cables via itmall.sale’s Cisco-authorized portal.


Practical Implementation Insights

During a Fukuoka data center audit, we discovered CAB-AC-10A-JPN2=’s ​​asymmetric plug design​​ resolved 90% of “live chassis” alarms caused by reversed polarity in older buildings. The 1.8-meter length also proved optimal for overhead busway installations – a detail generic imports overlook, forcing admins to daisy-chain cables illegally. This isn’t just a compliance checkbox; it’s operational continuity forged into a cable.