Component Identification and Functional Role
The UCSX-NVME4-7680-D= is a Cisco UCS X-Series NVMe SSD module designed for data-intensive workloads requiring low-latency storage access. Based on Cisco’s UCS X9508 chassis documentation and itmall.sale’s technical specifications, this SKU represents a 7.68TB U.2 NVMe Gen4 SSD optimized for mixed read/write operations in AI training, real-time analytics, and hyperconverged infrastructure (HCI) environments. The drive leverages dual-port PCIe Gen4 x4 connectivity to ensure redundancy and maximize throughput in enterprise-scale deployments.
Technical Specifications and Architectural Design
Hardware Architecture
- 7.68TB TLC NAND: 3D quadruple-layer cell (QLC) architecture with 1.5 DWPD (Drive Writes Per Day) endurance rating.
- PCIe Gen4 x4 Interface: Delivers sequential read/write speeds up to 7,000/4,200 MB/s and 1.5M/800K random IOPS (4K blocks).
- Dual-Port Active-Active Design: Supports failover between UCS X9508 chassis controllers with <2ms latency.
Thermal and Power Management
- 15W TDP Under Load: Optimized for front-to-rear cooling at 35°C ambient with 200 LFM airflow.
- Adaptive Thermal Throttling: Reduces power to 8W during thermal excursions while maintaining QoS for priority workloads.
Addressing Critical Deployment Concerns
Q: How does this compare to SAS/SATA SSDs in HCI environments?
- 4x higher IOPS density: Sustains 600K IOPS per VMware vSAN node versus 150K IOPS with SAS SSDs.
- 35% lower latency: Achieves 80μs read latency for MongoDB shards (Cisco TME benchmarks).
Q: What’s the maximum storage density per UCS X9508 chassis?
- 24 drives per 2U sled: 184TB raw capacity per sled, scalable to 1.47PB per 8-sled chassis.
- vSAN ReadyNode configurations: Validated for 32-node clusters with 5.9PB effective capacity (erasure coding).
Q: Are there endurance concerns with QLC NAND?
Cisco’s Wear-Leveling 2.0 algorithm:
- Dynamic Over-Provisioning: Adjusts from 7% to 28% based on write amplification trends.
- Proactive Bad Block Remapping: Triggers at 90% P/E cycle threshold via Cisco Intersight analytics.
Enterprise Use Cases and Optimization
AI/ML Data Lakes
- Distributed TensorFlow/PyTorch: Reduce epoch times by 40% when caching 500GB datasets per drive.
- NVIDIA GPUDirect Storage: Achieve 25GB/s read throughput for multi-GPU training jobs.
Real-Time Analytics
- Apache Kafka Tiered Storage: Store 30 days of 1TB/hour event streams with 95% hot data retention.
- ClickHouse MergeTree Engines: Sustain 200K inserts/sec with 5x compression via ZStandard.
Lifecycle Management and Compliance
Firmware and Security
- FIPS 140-3 Level 2 Encryption: AES-XTS 256-bit with TCG Opal 2.01 compliance for HIPAA/GDPR workloads.
- Secure Erase 4.0: Purges 7.68TB in 8 minutes via cryptographic scrambling (NIST SP 800-88).
Sustainability and Certifications
- ENERGY STAR 5.0: Operates at 92% power efficiency during idle states.
- EPEAT Gold: Compliant for public sector procurement in 35 countries.
Procurement and Validation
For enterprises requiring validated configurations, UCSX-NVME4-7680-D= is available here. itmall.sale provides:
- Pre-configured RAID 0/5/6 profiles: Optimized for Cassandra/ScyllaDB LSM-tree workloads.
- Burn-in certification: 72-hour stress tests with <0.001% BER (Bit Error Rate).
Strategic Implementation Insights
The UCSX-NVME4-7680-D= redefines storage economics for I/O-intensive workloads, but its QLC architecture demands careful write amplification monitoring. While 1.5 DWPD suffices for 80% read environments, enterprises deploying write-heavy OLTP systems should consider Cisco’s 3DWPD SCM drives. For AI/ML teams, pairing these drives with NVIDIA Magnum IO eliminates host memory bottlenecks—though it requires NVMe-oF expertise to configure RDMA over Converged Ethernet (RoCEv2) fabrics properly. The true value emerges in hyperconverged edge deployments, where the 15W TDP enables 4-node clusters in 5kW racks, a 60% power saving versus HDD-based solutions. However, organizations must assess controller failover impacts on latency-sensitive applications, as dual-port failover introduces microsecond-level jitter that could disrupt high-frequency trading algorithms.