Core Architecture & Electrical Specifications

The ​​UCS-M10CBL-C240M7​​ is Cisco’s proprietary GPU power delivery solution for the ​​C240 M7 rack server​​, specifically designed to support NVIDIA A100/H100 GPUs in the ​​UCS-GPU-FLEX170​​ configuration. This 10AWG copper cable delivers ​​2.4kW continuous power​​ at 200-240V AC with 94% peak efficiency. Key technical innovations include:

  • ​Triple-shielded insulation​​: Reduces EMI/RFI interference by 42dB compared to standard server cables
  • ​Smart current balancing​​: Automatically redistributes load across phases with <3% variance
  • ​NEMA 6-30P connector​​: Supports 30A circuits with IP67-rated dust/water resistance

Certified for ​​UL 62368-1​​ and ​​IEC 60950​​ safety standards, the cable implements ​​Cisco PowerSync technology​​ to maintain ±1% voltage stability during GPU compute spikes.


GPU Power Delivery Architecture

​Parallel power topology​​ enables simultaneous support for:

  1. ​8x NVIDIA H100 GPUs​​ at 700W each (5.6kW total)
  2. ​PCIe Gen5 backplane​​: 400W auxiliary power for NVMe storage arrays
  3. ​Redundant PSU integration​​: Seamless failover within 8ms during grid fluctuations

Key performance metrics:

  • ​Peak transient response​​: Handles 0-100% load steps in <50μs
  • ​Temperature resilience​​: Maintains 100% conductivity from -40°C to +105°C
  • ​Power loss prevention​​: Implements TUV-certified PLI (Power Loss Imminent) signaling

Compatibility & Deployment Scenarios

Validated configurations with Cisco UCS C240 M7 servers include:

GPU Configuration Cable Requirements Thermal Constraints
4x H100 SXM5 2x UCS-M10CBL-C240M7 25CFM airflow per GPU bay
8x A100 80GB PCIe 4x UCS-M10CBL-C240M7 Liquid cooling mandatory
Mixed CPU/GPU workloads 1:1 cable-to-GPU ratio 2200W PSU configuration

Third-party GPU racks require ​​Cisco UCS 6536 Fabric Interconnects​​ with 100Gbps RoCEv2 support for optimal power telemetry.


Safety & Monitoring Features

The cable integrates ​​Cisco Intersight power analytics​​ through:

power-monitoring policy gpu-cluster  
  sampling-rate 100ms  
  anomaly-detection enable  
  thermal-derating auto  

​Operational thresholds​​:

  • ​Continuous current​​: 30A ±5% (derates above 40°C ambient)
  • ​Insulation resistance​​: >100MΩ at 500VDC
  • ​Bend radius​​: Minimum 50mm for 90° installations

For procurement details, visit [“UCS-M10CBL-C240M7” link to (https://itmall.sale/product-category/cisco/).


Deployment Best Practices

​Critical installation guidelines​​:

  1. ​Rack power sequencing​

    psu-config ai-rack  
     phase-rotation ABC-CAB-BCA  
     soft-start-delay 500ms  
  2. ​Cable management​
    Maintain 75mm clearance between parallel cables to prevent:

    • Mutual inductance (>5μH/m)
    • Skin effect losses at 60Hz
  3. ​Grounding requirements​

    grounding-spec hyperscale  
     chassis-ground 10AWG  
     pdu-ground 6AWG  
     impedance <0.1Ω  

Operational Insights from Hyperscale Deployments

In Tokyo’s AI research clusters, the cables demonstrated ​​99.999% power availability​​ during 72-hour sustained LLM training sessions. The ​​adaptive current balancing​​ feature reduced PDU harmonic distortion from 8.2% to 2.1% – critical for maintaining GPU compute accuracy in FP64 precision modes.

What truly sets this solution apart isn’t the raw power delivery specs, but its ​​holistic integration with Cisco’s thermal management ecosystem​​. While competitors treat power cables as passive components, the UCS-M10CBL-C240M7’s real-time telemetry feeds into UCS Manager’s predictive algorithms – enabling true cross-domain optimization of power, cooling, and compute resources. For enterprises pushing the boundaries of GPU-accelerated computing, this cable represents the missing link between theoretical TFLOPs and real-world AI infrastructure reliability.

Related Post

IEM-3300-16T=: What Is This Cisco Industrial

​​Decoding the IEM-3300-16T=: Cisco’s Rugged Netw...

Cisco UCS-NVME4-7680-D Hyperscale NVMe Accele

​​Core Hardware Specifications​​ The Cisco UCS-...

CP-8832-NR-K9++: How Does It Deliver Scalable