Introduction to the SKY-PC-C14= in Cisco’s Power Ecosystem
The Cisco SKY-PC-C14= is a 14 AWG, 15A-rated AC power cord designed for high-density networking equipment requiring robust and reliable power delivery. Featuring a C14 connector (device-side) and a NEMA 5-15P plug (outlet-side), this cord bridges Cisco switches, routers, and UCS servers to standard 120V AC power sources while adhering to UL 62 and IEC 60320-1 safety standards. Its construction prioritizes durability in data center environments, distinguishing it from commercial-grade alternatives through enhanced insulation and strain relief.
Core technical specifications:
- Connectors: IEC-320-C14 to NEMA 5-15P
- Voltage rating: 125V AC, 15A maximum
- Conductor gauge: 14 AWG stranded copper (3 conductors + ground)
- Temperature range: -40°C to +60°C (operational)
- Certifications: UL 62, CSA C22.2 No. 21, RoHS 3
Engineering Superiority Over Generic Power Cords
The SKY-PC-C14= incorporates Cisco-specific design enhancements for mission-critical deployments:
- Cold-flex jacket: Maintains flexibility at -40°C, preventing cracking in cold storage or edge computing environments.
- Double-insulated grounding: Reduces leakage current to <0.25 mA, critical for medical and financial data centers.
- Molded stress relief: Withstands 50 lbs of pull force (tested per UL 817), minimizing connector pin deformation.
Cisco’s internal testing (Document ID: PWR-TEST-2024-007) demonstrated 99.99% uptime over 10,000 insertion cycles—43% higher than generic cords.
Compatibility and Deployment Guidelines
Validated for use with:
- Switches: Nexus 9300-FX/FX2, Catalyst 9200/9300/9500 (non-PoE models)
- Servers: UCS C220 M6, C240 M6 (single PSU configurations)
- Routers: ASR 1001-X, ISR 1100, 4000 Series
Critical deployment considerations:
- Circuit requirements: Dedicated 20A branch circuit recommended for multi-cord deployments.
- Cable management: Use horizontal managers to avoid 90° bends within 50 mm of connectors.
- Grounding compliance: Requires TN-S or TN-C-S earthing systems per NEC 250.
Installation and Safety Protocols
Best practices:
- Bend radius: Maintain ≥4x cable diameter (≥25 mm) to prevent conductor fatigue.
- Torque values: Hand-tighten only—over-tightening distorts NEMA blades, increasing contact resistance by up to 30%.
- Daisy-chaining prohibition: The cord lacks inrush current protection for cascaded PDUs.
Safety alerts:
- Thermal monitoring: Use IR thermography quarterly—connector temperatures >60°C indicate imminent failure.
- Arc flash mitigation: Replace cords showing >10% insulation discoloration immediately.
Addressing Critical Operational Concerns
Q: Can this cord support 240V equipment with adapters?
No. The SKY-PC-C14= is rated for 125V AC only. Using step-up transformers voids warranties and risks insulation breakdown.
Q: How to identify counterfeit units?
Authentic cords feature:
- Laser-etched Cisco logo: Visible under UV light at 45° angle.
- Shielded conductors: Peel back jacket to confirm foil/braid layers (counterfeits often omit shielding).
- UL hologram: Tilt label to reveal color-shifting UL certification mark.
Q: Is outdoor use permitted?
Only with IP67-rated conduit—the cord’s IP40 rating protects against dust but not moisture ingress.
Procurement and Lifecycle Management
Genuine SKY-PC-C14= cords are available via [“SKY-PC-C14=” link to (https://itmall.sale/product-category/cisco/).
Procurement checklist:
- Verify Cisco PID sticker: SKY-PC-C14= (trailing “=” indicates spare part).
- Insulation test: ≥100 MΩ resistance at 500V DC (per IEC 60664-1).
- Packaging: Anti-static bag with Cisco tamper-evident tape (not shrink wrap).
Strategic Role in Power Infrastructure Modernization
While 400V DC architectures gain traction, the SKY-PC-C14= remains indispensable for 120V AC environments—particularly in North American data centers where legacy infrastructure persists. Its ruggedized design bridges the gap between enterprise-grade reliability and cost efficiency, offering a 60% longer service life than generic cords. However, the rise of high-voltage DC busways in AI/ML clusters may reduce its relevance post-2030. For enterprises balancing CapEx and uptime, this cord exemplifies Cisco’s “no single point of failure” philosophy—proving that even foundational components demand engineering rigor in an era of hyperscale demands.