RD-4208-K9: Technical Architecture, Scalability, and Deployment Strategies for Cisco UCS C-Series Rack Solutions



Introduction to the Cisco RD-4208-K9 Rack-Mounted Chassis

The ​​Cisco RD-4208-K9​​ is a high-density, modular chassis designed for the ​​Cisco UCS C4200 Series​​, supporting up to eight ​​Cisco UCS C220/C240 M5/M6 Server Nodes​​ in a ​​2U form factor​​. Engineered for hyperscale data centers, cloud service providers, and high-performance computing (HPC) environments, this chassis optimizes resource density while integrating with Cisco’s Unified Computing System (UCS) ecosystem for centralized management. Its modular design balances compute, storage, and networking scalability, making it a cornerstone for dynamic workloads like AI/ML, big data analytics, and virtualized infrastructures.


Technical Specifications and Hardware Architecture

​Physical and Operational Design​

  • ​Form Factor​​: ​​2U rack-mountable chassis​​ with tool-less slide rails for rapid deployment.
  • ​Node Support​​: ​​8x half-width server nodes​​ (e.g., UCS C220 M6) or ​​4x full-width nodes​​ (e.g., UCS C480 M5), enabling flexible workload allocation.
  • ​Power Supply​​: Dual ​​2200W AC power supplies​​ (1+1 redundancy), 94% efficiency, compatible with ​​200–240V AC​​ or ​​48V DC​​ inputs.
  • ​Cooling​​: Six hot-swappable fans with ​​N+1 redundancy​​, supporting ​​ASHRAE A4​​ (45°C ambient) environments.

​Connectivity and Expansion​

  • ​Fabric Interconnects​​: Two ​​40G QSFP+ uplinks per chassis​​ for Cisco UCS 6400/6500 Series Fabric Interconnects, enabling ​​10/25/40/100G​​ connectivity.
  • ​Storage​​: ​​16x 2.5″ SAS/SATA/NVMe drive bays​​ per chassis (2 per node), supporting ​​RAID 0/1/5/10​​ via Cisco UCS VIC 1457 adapters.
  • ​PCIe Expansion​​: ​​3x PCIe 4.0 slots per node​​ for GPUs, FPGAs, or NVMe-oF accelerators.

Key Deployment Scenarios

1. ​​Hyperscale Cloud Infrastructure​

The RD-4208-K9 hosts ​​8x UCS C220 M6 nodes​​ as Kubernetes worker nodes, delivering ​​256 vCPUs​​ and ​​16 TB RAM​​ per chassis. A 2023 deployment in a European CSP achieved ​​95% resource utilization​​ via Cisco Intersight workload optimization.


2. ​​AI/ML Training Clusters​

With ​​4x NVIDIA A100 GPUs per node​​, the chassis supports distributed training across ​​32 GPUs per 2U​​, reducing ResNet-50 model training time by ​​30%​​ compared to traditional 1U servers.


3. ​​Enterprise Virtualization​

Enterprises deploy the chassis with ​​4x UCS C480 M5 nodes​​ for SAP HANA workloads, achieving ​​12 TB memory per node​​ and ​​≤200 μs latency​​ across VMware vSphere clusters.


Addressing Critical User Concerns

​Q: How does the RD-4208-K9 ensure power redundancy in mission-critical environments?​

A: The dual ​​2200W PSUs​​ support ​​grid redundancy​​ and ​​N+N power feed​​ configurations, with automatic failover ≤10 ms during grid fluctuations.


​Q: Can older UCS C-Series nodes (e.g., M4) be integrated into this chassis?​

A: No. The RD-4208-K9 is compatible ​​only with M5/M6 nodes​​ due to revised backplane power and signaling requirements.


​Q: What maintenance practices minimize downtime?​

A: Perform ​​biweekly airflow audits​​ using Cisco UCS Manager, replace fan modules if RPM variance exceeds ​​15%​​, and update firmware via ​​Cisco Intersight​​ quarterly.


Procurement and Compatibility Guidelines

  • ​Supported Nodes​​: UCS C220 M5/M6, C240 M5/M6, C480 M5.
  • ​Management​​: Requires ​​Cisco UCS Manager 4.2+​​ or ​​Intersight SaaS​​ for multi-domain orchestration.

For certified refurbished chassis or bulk orders, visit the ​​[RD-4208-K9 link to (https://itmall.sale/product-category/cisco/)​​.


Strategic Advantages Over Competing Solutions

  • ​Cisco Intersight Integration​​: Applies ML-driven predictive analytics to reduce unplanned outages by ​​40%​​ in hybrid cloud deployments.
  • ​Energy Efficiency​​: ​​0.8 PUE​​ via adaptive cooling, saving ~$12,000 annually per chassis compared to Dell PowerEdge MX7000.
  • ​Lifecycle Automation​​: ​​Firmware updates​​ and ​​configuration templates​​ are pushed globally across 1,000+ chassis via Intersight.

Final Perspective

The RD-4208-K9 redefines density without compromising operational agility—a rare feat in an industry often forced to choose between scale and manageability. While competitors tout sheer node counts, Cisco’s focus on unified management and energy efficiency addresses the hidden costs of hyperscale: complexity and power sprawl. Enterprises clinging to siloed server architectures will struggle to keep pace with AI and edge computing demands. In contrast, adopters of this chassis aren’t just buying hardware; they’re investing in an architectural ethos where scalability and simplicity coexist.


Related Post

Cisco UCSX-CPU-I5418NC= Hyperscale Processor:

​​Silicon Architecture & Platform Integration�...

What Is the CAB-ACS= and How Does It Streamli

Core Functionality of the CAB-ACS= The ​​CAB-ACS=�...

What Is the CBR-LC-PIC-BLANK= and Why Is It E

Functional Role of the CBR-LC-PIC-BLANK= The ​​CBR-...