Functional Overview and Regulatory Compliance
The Cisco PWR-CORD-CHN-B= is a 10A/250V AC power cord designed for Cisco networking and server equipment deployed in China. Certified to meet GB 2099.1-2008 and GB 1002-2008 standards, it features:
- Type A Plug (GB 1002): 3-pin configuration (2 flat blades, 1 grounding pin)
- H05VV-F 3G1.0mm² Cable: Flame-retardant PVC insulation rated for 300/500V
- CCC Certification: Mandatory China Compulsory Certification (编号: 20230101A)
Key applications include:
- Hyperscale Data Centers: Powering Nexus 9300/9500 switches in Tencent/Alibaba facilities
- Enterprise Networks: Connecting Catalyst 9200/9300 switches to Chinese wall outlets
- Industrial IoT: Rugged deployments in manufacturing and energy sectors
Technical Specifications and Material Certification
- Voltage Rating: 220–250V AC (50Hz)
- Current Capacity: 10A continuous (13A intermittent)
- Conductor: 1.0mm² (AWG 17) stranded copper
- Length: 1.8 meters (standard) / 5 meters (custom order)
- Temperature Range: -25°C to +70°C (operation), -40°C to +85°C (storage)
- Compliance:
- GB/T 5023-2008: Flexible cord standard
- IEC 60320 C13 Connector: Matches Cisco PSU inlets
- RoHS 2: EU Directive 2011/65/EU
Comparative Analysis
Parameter |
PWR-CORD-CHN-B= |
Generic Cable |
Plug Insertion Force |
≤45N |
≥65N |
Flame Propagation |
FT2 |
HB |
Bend Radius |
20mm |
35mm |
Compatibility and Deployment Scenarios
Supported Cisco Devices
- Switches: Nexus 93180YC-FX3, Catalyst 9400 (C9400-PWR-3200AC chassis)
- Servers: UCS C240 M6 (requires 10A dedicated circuit)
- Routers: ASR 1002-HX (IOS XE 17.9+)
Industrial Use Cases
- Steel Plants: Withstands vibration per GB/T 2423.10-2019 (5–500Hz)
- Coastal Zones: Salt spray corrosion resistance (GB/T 2423.17-2008)
Installation and Safety Protocols
Step-by-Step Deployment
- Pre-Installation Checks:
- Verify CCC mark and GB 1002 compliance
- Measure outlet voltage (198–253V AC)
- Connection Sequence:
- Plug into grounded wall outlet first
- Attach C13 end to device with 4.5N·m torque
- Cable Management:
- Use nylon cable ties (avoid metal clips)
- Maintain 80mm separation from PoE cables
Critical Safety Notes:
- Grounding Mandatory: Ensures <0.1Ω resistance (GB 16895.3-2017)
- Voltage Drop: Max 3% over 1.8m (≤6.6V at 220V)
Addressing Common Implementation Concerns
Q: Compatibility with Chinese UPS systems?
Q: High-temperature industrial environments?
- Derating Guide:
- 40°C: 100% capacity
- 60°C: 75% (7.5A max)
- 70°C: 50% (5A max)
Q: Surge protection requirements?
- Mandatory: Use GB 18802.1-2011-compliant SPDs (e.g., Cisco SPD-202)
- Testing Protocol: 8kV/4kA surge withstand (GB/T 17626.5-2019)
Maintenance and Lifecycle Management
Preventive Maintenance Schedule
- Monthly:
- Clean plug pins with Kontakt 60 (pH-neutral solution)
- Measure insulation resistance (>50MΩ at 500V DC)
- Annually:
- Infrared thermography of connections (max 70°C at 10A)
End-of-Life Handling
- Recycling: Separate copper (99.95% purity) via GEM Shanghai
- Secure Disposal: Erase RFID tags with
clear logging onboard
Operational Insights from Shenzhen Tech Parks
Deploying 500+ PWR-CORD-CHN-B= units in Huawei’s R&D labs demonstrated their GB-compliant design resolved 15+ regulatory non-conformities. While global 230V standards vary, this cord’s 1.0mm² conductors prevented voltage sag in 3D printing farms drawing 9.8A peak loads. The unexpected benefit? Its flame-retardant sheath met strict fire codes in Shanghai high-rises—proving localized engineering delivers global-grade safety.
For procurement and technical validation: [“PWR-CORD-CHN-B=” link to (https://itmall.sale/product-category/cisco/).