Cisco PWR-5400-AC=: High-Performance 5.4kW AC Power Supply for Data Center and Enterprise Networks



​Product Overview and Design Philosophy​

The ​​Cisco PWR-5400-AC=​​ is a ​​5,400-watt AC power supply​​ engineered for high-density data center switches, routers, and converged infrastructure platforms, including the ​​Cisco Nexus 9500 Series​​ and ​​Cisco UCS X-Series​​. Designed to meet the escalating power demands of AI/ML workloads, 800G networking, and hyperscale cloud deployments, this PSU combines ​​energy efficiency​​, ​​modular redundancy​​, and ​​advanced thermal management​​ for mission-critical environments. Key design principles include:

  • ​Dual-Input Flexibility​​: Supports ​​200–277V AC​​ (50/60 Hz) with ​​auto-ranging capability​​, enabling seamless integration into diverse grid infrastructures.
  • ​High Efficiency​​: ​​96% efficiency​​ at 50% load, compliant with ​​80 Plus Titanium​​ and ​​ENERGY STAR 5.0​​ standards.
  • ​Scalable Redundancy​​: ​​N+1/N+N configurations​​ in ​​Cisco UCS 6454 Fabric Interconnects​​, ensuring ​​≤3 ms failover​​ during power disruptions.

The PSU integrates with ​​Cisco Intersight​​ for real-time power analytics and predictive maintenance, critical for environments requiring ​​99.999% uptime SLAs​​.


​Technical Specifications and Certifications​

Cisco’s 2024 Power Infrastructure Validation Report confirms:

  • ​Electrical Performance​​:
    • ​Input Voltage​​: ​​200–277V AC​​ (±10% tolerance) or ​​-48V DC​​ (±20% tolerance).
    • ​Output​​: ​​12V DC ±0.8%​​, ​​450A continuous current​​ (EN 50178).
  • ​Protection Mechanisms​​:
    • ​Over-Current Protection (OCP)​​: ​​500A​​ threshold with ​​<50 μs​​ response time.
    • ​Thermal Management​​: ​​Triple 60mm fans​​ with ​​N+1 redundancy​​, maintaining internal temps ​​≤65°C​​ at full load.
  • ​Certifications​​: ​​UL 60950-1​​, ​​NEBS Level 3​​, ​​CE Mark​​, ​​RoHS 3​​.
  • ​Environmental Compliance​​:
    • Operating Temperature: ​​0°C to 55°C​​ (ASHRAE Class A4).
    • Humidity: ​​5–95% non-condensing​​ (IEC 60068-2-78).

Lab tests achieved ​​MTBF (Mean Time Between Failures) of 2.3 million hours​​ under ​​55°C ambient stress​​ and ​​99.999% uptime​​ during ​​45-day load cycling​​.


​Key Use Cases and Deployment Scenarios​

​1. Hyperscale AI/ML GPU Clusters​

A North American cloud provider deployed 80 PSUs in ​​Cisco Nexus 9336C-FX2​​ spines to power ​​NVIDIA H100 GPU racks​​, sustaining ​​≤0.5% voltage ripple​​ during ​​12,000A transient spikes​​ in generative AI workloads.

​2. Industrial Edge Compute with Harsh Conditions​

A German automotive manufacturer used the PSU in ​​Cisco IE 3400 switches​​ within robotic paint shops, enduring ​​25G vibrations​​ and ​​solvent exposure​​ while maintaining ​​99.99% uptime​​.

​3. Telecom 5G Core Network Power Resilience​

An Asian carrier integrated the PSU into ​​Cisco NCS 5700 routers​​ to support ​​15 kW per rack​​ density for ​​5G UPF (User Plane Function)​​ workloads during grid instability.


​Addressing Critical Customer Concerns​

​Q: How does it handle voltage fluctuations in unstable grids?​

The ​​Active Harmonic Correction (AHC)​​ circuit maintains ​​THD (Total Harmonic Distortion) ≤3%​​ even at ​​180V AC input​​, complying with ​​EN 61000-3-2​​.

​Q: Is it compatible with lithium battery backups?​

Yes, via ​​Cisco RSP-7800 battery shelves​​, but requires ​​LiFePO4 chemistry​​ for ​​-20°C charging​​ compatibility and ​​≥8,000 cycle life​​.

​Q: What maintenance ensures optimal performance?​

  • ​Quarterly​​: Clean ​​fan filters​​ with ​​Cisco CAB-CLN-FAN​​ tools to prevent ​​≥20% airflow reduction​​.
  • ​Biannual​​: Test ​​hold-up time​​ (>22 ms per EN 61000-4-11) using ​​Cisco PWR-TESTER-5KW=​​.

​Installation and Optimization Best Practices​

  1. ​Phase Balancing​​:
    • Distribute PSUs across ​​three-phase circuits​​ to limit ​​neutral current imbalance​​ to ​​≤2%​​ (IEEE 519).
  2. ​Grounding Compliance​​:
    • Use ​​4/0 AWG grounding cables​​ (≤0.05 Ω resistance) bonded to ​​UL 467​​-listed busbars.
  3. ​Firmware Management​​:
    • Upgrade via ​​Cisco UCS Manager​​ to enable ​​Adaptive Voltage Scaling (AVS)​​ for dynamic load adjustments.

For enterprises migrating from ​​AC/DC hybrid systems​​, Cisco offers ​​trade-in rebates covering 25% of costs​​ under its Power Modernization Program.


​Why Hyperscalers and Enterprises Choose This PSU​

  • ​Total Cost of Ownership​​: ​​$5,800 per unit​​ (TCO over 10 years), ​​35% lower​​ than HPE/ABB equivalents.
  • ​Compliance​​: Meets ​​ANSI/TIA-942 Tier IV​​ and ​​ISO 50001​​ for energy management.
  • ​Future-Proofing​​: Supports ​​1.6T CPO (Co-Packaged Optics)​​ with ​​≤3% power overhead​​.

For procurement details, visit the Cisco PWR-5400-AC= product page at ITMall.sale.


​Operational Insights from Extreme Environments​

From Arctic data centers to tropical edge sites, two universal lessons emerge:

  1. ​Dust Kills Efficiency​​: A Middle Eastern hyperscaler reduced ​​PSU failures​​ by ​​55%​​ after enforcing ​​weekly filter cleaning​​—proof that even Titanium-rated efficiency falters without airflow.
  2. ​Redundancy Isn’t Optional​​: A Tokyo stock exchange survived a ​​grid collapse​​ by leveraging ​​N+N redundancy​​, avoiding ​​$75M in trading losses​​ during a typhoon-induced blackout.

In an industry racing toward quantum leaps in compute and connectivity, the PWR-5400-AC= serves as a grounding reminder: ​​the most transformative innovations are meaningless without electrons to power them​​. For engineers, it’s a humbling paradox—while the world marvels at AI breakthroughs, this PSU’s unyielding reliability ensures those breakthroughs aren’t reduced to theoretical curiosities. After all, in the silent dance of electrons, consistency is the ultimate innovation.

Related Post

DS-C9396V-96ITK9P: Cisco’s Hyperscale Data

Decoding the Product Identity The ​​DS-C9396V-96ITK...

Cisco C9124AXI-Q Access Point: How Does It So

​​Defining the C9124AXI-Q’s Industrial Focus​�...

Cisco NCS4K-DC-FA= Direct Current Fan Assembl

Hardware Design and Functional Specifications The ​�...