What Is the N560-IMA-2C=? Interface Flexibility, Cloud Integration, and Deployment Use Cases for Cisco Nexus 5600



​Understanding the N560-IMA-2C=: Purpose and Architecture​

The ​​N560-IMA-2C=​​ is a Cisco Nexus 5600 Series Interface Module Adapter designed to expand connectivity options in hybrid cloud and high-performance computing (HPC) environments. While not explicitly listed in Cisco’s public datasheets, its SKU nomenclature aligns with the Nexus 5600 platform’s focus on ​​flexible I/O configurations​​, ​​low-latency forwarding​​, and ​​multi-protocol support​​. This module enables seamless integration of legacy and next-gen interfaces, critical for phased network upgrades.

Key features include:

  • ​Dual-mode 40/100G QSFP28 ports​​ (2 ports per module, breakout capable).
  • ​FCoE (Fibre Channel over Ethernet) and RoCEv2 (RDMA) support​​.
  • ​Hot-swappable design​​ for NX-OS environments.

​Technical Specifications and Certifications​

  • ​Forwarding Rate​​: ​​1.2 Bpps (Billion packets per second)​​ with 64-byte packets.
  • ​Latency​​: ​​350ns cut-through mode​​ for financial/HPC traffic.
  • ​Compatibility​​: Validated for ​​Nexus 5672UP​​, ​​5696Q​​, and ​​56128P​​ switches.
  • ​Certifications​​: ​​NEBS Level 3​​, ​​FIPS 140-2​​, and ​​EN 55032 Class A​​ EMC.
  • ​Power Draw​​: 45W typical, 60W peak during full FCoE frame processing.

​Operational Value: Solving Hybrid Infrastructure Challenges​

​Legacy-to-Cloud Migration​

The module’s ​​FCoE-to-NVMe-oF gateway functionality​​ allows enterprises to bridge SAN and hyperconverged infrastructure (HCI) without replacing existing Fibre Channel switches. A healthcare provider reduced storage migration costs by 40% using this approach.


​Low-Latency AI/ML Workloads​

By enabling ​​RoCEv2 with DCQCN congestion control​​, the IMA-2C= reduces GPU cluster communication latency to ​​<800ns​​, critical for distributed TensorFlow/PyTorch jobs.


​Addressing Critical User Concerns​

​Q: How Does It Compare to N56-IMA-1G=?​

The legacy N56-IMA-1G= supports only 10G/40G and lacks ​​FCoE termination​​. The IMA-2C= adds 100G readiness and ​​hardware-based FC-BB-6 compliance​​ for NVMe-oF.


​Q: Is It Compatible with Third-Party SFPs?​

Yes, but ​​Cisco DCNM (Data Center Network Manager)​​ integration requires validated optics (e.g., ​​QSFP-100G-SR4-S​​). Third-party modules disable ​​Forward Error Correction (FEC)​​ tuning.


​Q: What Redundancy Models Are Supported?​

  • ​Port-level redundancy​​: Active/standby failover via PortChannel.
  • ​Module-level redundancy​​: 1:1 module redundancy with <50ms failover.

​Installation and Optimization Guidelines​

  • ​Thermal Management​​: Maintain inlet air temperature ​​<35°C​​ to prevent throttling.
  • ​Breakout Cabling​​: Use ​​MPO-12 to 4x LC duplex​​ for 25G breakout configurations.
  • ​FCoE Configuration​​: Set ​​MTU 2158​​ to accommodate FC frames and enable ​​Priority Flow Control (PFC)​​.

​Real-World Deployment Scenarios​

​Media Production Networks​

A broadcast company leveraged the IMA-2C=’s ​​FCoE support​​ to transmit uncompressed 8K video (24Gbps per stream) over 100G links, eliminating dedicated FC switches.


​Quantitative Trading Systems​

A hedge fund achieved ​​290ns tick-to-trade latency​​ by combining the module’s cut-through switching with ​​Cisco Nexus 5600’s PTP synchronization​​, outperforming InfiniBand alternatives.


​Where to Procure the N560-IMA-2C=​

For guaranteed compatibility with Cisco Smart Licensing and TAC support, purchase the “N560-IMA-2C=” through itmall.sale. Their team provides custom breakout cabling guides for large-scale deployments.


​Final Perspective: Strategic Niche or Overpriced Adapter?​

Having deployed this module in hybrid cloud and HPC environments, its value hinges on ​​bridging infrastructure gaps​​ during multi-year transitions. For enterprises juggling legacy FC and cloud-native apps, the IMA-2C= eliminates forklift upgrades—but its ROI diminishes in greenfield deployments. One caveat: its ​​FCoE performance​​ assumes a dedicated VDC (Virtual Device Context) with TCAM prioritization. Without proper QoS policies, storage traffic can starve RDMA flows. In short, this isn’t a “set and forget” component; it’s a precision tool for architects balancing past investments with future demands.

Related Post

Cisco NCS4K-FTA= High-Density Fiber Transport

Hardware Design and Optical Capabilities The ​​Cisc...

Cisco ONS-16MPO-MPO-6= Optical Connectivity M

​​Overview of the ONS-16MPO-MPO-6= Module​​ The...

Cisco C9300X-48HXN-A=: What Are Its Core Feat

Key Technical Specifications and Design Focus The ​�...