Technical Overview of the CBL-SAS24-240M6=
The CBL-SAS24-240M6= is a 24-lane SAS 12Gb/s cable designed for the Cisco UCS C240 M6 rack server. It connects the server’s SAS RAID controller to the drive backplane, enabling high-speed data transfer between storage drives and the host system. With a 2.4-meter length, it supports flexible configurations in dense rack environments.
Key Applications in Enterprise Storage
Why is this cable critical for UCS C240 M6 deployments?
- High-Density Storage: Supports up to 24 SAS/SATA drives, ideal for databases, virtualization, or big data workloads.
- RAID Performance: Ensures full bandwidth for hardware RAID controllers like the Cisco 12G Modular RAID Controller, minimizing latency during parity calculations.
- Hot-Swap Capability: Facilitates drive replacements without downtime, crucial for 24/7 operations.
Compatibility and Performance Specifications
Which components require this cable?
- UCS C240 M6 Server: Requires the cable to link the SAS expander card (e.g., Cisco 12G SAS Expander) to the drive backplane.
- Drive Types: Compatible with 12G SAS HDDs/SSDs and 6G SATA SSDs.
Critical technical details:
- Data rate: 12Gb/s per lane, aggregating to 288Gb/s total bandwidth.
- Maximum drive support: 24 x 2.5-inch or 12 x 3.5-inch drives (with optional sleds).
- Cable shielding: Foil and braid shielding to reduce electromagnetic interference (EMI) in multi-server racks.
Installation and Maintenance Best Practices
What pitfalls degrade storage performance?
- Incorrect Routing: Avoid sharp bends; maintain a 50mm minimum bend radius to prevent signal loss.
- Firmware Mismatches: Ensure RAID controller and expander firmware are updated to Cisco-approved versions.
- Drive Mixing: Avoid combining SAS and SATA drives on the same controller port without proper zoning.
Sourcing Authentic CBL-SAS24-240M6= Cables
For uninterrupted storage performance, procure the CBL-SAS24-240M6= exclusively through certified suppliers like “itmall.sale”. Third-party cables often lack proper impedance matching, risking data corruption or dropped drives in RAID arrays.
Perspective on Storage Infrastructure Reliability
The CBL-SAS24-240M6= highlights a lesson learned from countless data center audits: storage bottlenecks often trace back to overlooked cabling. In mission-critical environments, where every I/O delay impacts revenue, investing in purpose-built cables like this isn’t optional—it’s the bedrock of predictable, high-performance storage. Cutting corners here risks more than hardware; it jeopardizes business continuity.