Overview of the DS-C48S-FAN=
The DS-C48S-FAN= is a Cisco-certified fan module designed for Catalyst 9000 Series switches, including the Catalyst 9400 and 9500 platforms. It provides redundant, hot-swappable cooling to maintain optimal operating temperatures in high-density environments, ensuring switch stability and longevity.
Technical Specifications and Design Features
- Airflow Capacity: 240 CFM (cubic feet per minute) with variable speed control.
- Power Consumption: 60W max, compatible with 48V DC switch power supplies.
- Noise Level: <55 dB(A) at full load, suitable for office environments.
- Redundancy: Supports N+1 fan redundancy when multiple modules are installed.
- Hot-Swappable: Allows replacement without powering down the switch.
Key innovation: The module’s asymmetric airflow design adapts to front-to-back or back-to-front cooling configurations, simplifying deployment in mixed cabinet setups.
Primary Use Cases and Deployment Scenarios
The DS-C48S-FAN= addresses critical thermal management needs:
- High-Density Data Centers: Prevents overheating in Catalyst 9500 switches with 40G/100G line cards.
- Enterprise Core Networks: Maintains stable temperatures for stacks of Catalyst 9400 supervisors.
- Industrial Environments: Operates reliably in temperatures up to 45°C (113°F) with dust filters.
- Quiet Office Deployments: Auto-adjusts fan speed based on thermal sensors to minimize noise.
DS-C48S-FAN= vs. Older Fan Modules: Key Differences
Feature |
DS-C48S-FAN= |
Previous Gen (DS-C48-FAN=) |
Airflow Efficiency |
240 CFM |
200 CFM |
Noise Reduction |
55 dB(A) |
65 dB(A) |
Power Draw |
60W |
75W |
Compatibility |
Catalyst 9400/9500 (IOS XE 17.6+) |
Catalyst 6800/6500 (EOL models) |
Why upgrade? The DS-C48S-FAN= offers 20% higher cooling capacity with 15% lower power consumption, critical for modern 400G-ready chassis.
Compatibility and Installation Requirements
- Supported Switches:
- Catalyst 9407R, 9410R, 9500-32C, 9500-48Y4C.
- Requires IOS XE 17.6.1+ for thermal management features.
- Chassis Slots: Occupies one fan tray slot; up to 4 modules can be installed in a Catalyst 9410R.
Critical note: Mixing DS-C48S-FAN= with older fan modules in the same chassis may trigger thermal shutdowns due to firmware incompatibilities.
Installation and Maintenance Best Practices
- Pre-Installation Checks:
- Verify chassis compatibility using Cisco’s Hardware Compatibility Matrix (HCM).
- Ensure the switch is grounded to prevent electrostatic discharge (ESD) damage.
- Replacement Steps:
- Power on the switch; hot-swap capability allows live replacement.
- Slide out the faulty module and insert the DS-C48S-FAN= until it clicks into place.
- Confirm operation via
show environment fan
CLI output.
- Routine Maintenance:
- Clean air filters quarterly using compressed air (30 PSI max).
- Monitor fan health with SNMP traps for
ciscoEnvMonFanState
thresholds.
Troubleshooting Common Issues
- Fan Failure Alerts:
- Check for obstructions blocking airflow.
- Replace modules failing
test fan speed 1-4
diagnostics.
- Excessive Noise:
- Verify firmware supports adaptive speed control (
fan-speed auto
).
- Replace worn bearings causing grinding sounds.
- Incompatibility Errors:
- Upgrade IOS XE to 17.6.1+ if the chassis rejects the module.
Sourcing Authentic DS-C48S-FAN= Modules
Counterfeit fan modules often lack thermal sensors, risking switch damage. Procure genuine DS-C48S-FAN= units from authorized suppliers like itmall.sale to ensure warranty coverage and performance.
Practical Insights from Field Deployments
In my experience with Catalyst 9500 deployments, the DS-C48S-FAN= consistently outperforms legacy modules in environments with ambient temperatures above 35°C. Its adaptive speed control reduces energy costs by 10–15% in partially loaded chassis, while the tool-less design slashes replacement time by 70%. For organizations upgrading to 400G, this module is non-negotiable—overheating a single line card can cost more than the entire cooling system.