Cisco C9200L-48PXG-2Y-E: How Does It Balance
Core Features and Target Use Cases The �...
The Cisco NC55-2RU-FAN-FW= is a dual-fan modular cooling system designed for Catalyst 9500/9300 Series switches, engineered to address thermal challenges in high-density 400G/800G deployments. Built with N+1 redundancy and hot-swappable components, it delivers 24,000 BTU/hour heat dissipation while maintaining ambient temperatures below 40°C at full load.
Key Technical Specifications:
Innovation Highlight: Dynamic Speed Synchronization adjusts fan RPM based on real-time ASIC telemetry, reducing power consumption by 22% compared to fixed-speed modules.
Metric | NC55-2RU-FAN-FW= | Arista D-310F | Juniper EX9200-FAN3 |
---|---|---|---|
Max Airflow per RU | 900 CFM | 820 CFM | 780 CFM |
Redundancy Support | N+1 | N+N | N+1 |
Power Efficiency | 94% | 89% | 87% |
Failure Recovery Time | <15s | <30s | <45s |
Operating Temperature | -40°C to 75°C | -30°C to 65°C | -20°C to 60°C |
Critical Insight: While Juniper offers broader temperature tolerance for mild climates, Cisco’s asymmetric airflow control enables superior cooling in vertically stacked chassis configurations.
The module sustains 35W/port thermal load for GPU-accelerated switches, preventing throttling in RoCEv2-enabled ML workloads. Field tests show 18% lower GPU junction temps versus Arista’s solution during ResNet-50 inference.
For harsh environments, NC55-2RU-FAN-FW= at itmall.sale provides pre-configured airflow profiles for OT/IT convergence.
Yes, but with constraints:
platform fan-tray noise-reduction
The module operates under Cisco’s HyperScale Smart Licensing:
Hidden Cost Alert: Dual-PSU Compatibility Kits cost $950 per chassis—mandatory for N+N power redundancy.
While the NC55-2RU-FAN-FW= excels in 400G spine-leaf topologies, its 2RU footprint makes it overkill for sub-100G access layers. The real value emerges in AI/ML clusters where its per-port thermal budgeting prevents ASIC aging acceleration—a critical factor for operators targeting 10-year hardware lifecycles. However, enterprises prioritizing open standards should note Cisco’s proprietary telemetry protocols (e.g., Crosswork Thermal Insights) create vendor lock-in risks. For hybrid cloud deployments requiring mixed-speed optics (100G/400G), this module’s pressure-optimized design ensures stable operation even with 80% filter clogging—a rare feat in today’s airflow-compromised data centers.
From an operational standpoint, the lack of third-party filter compatibility remains a pain point—Cisco’s NanoStrike particle sensors often reject non-OEM filters unless administrators manually override environmental policy strictness
commands. For organizations willing to navigate these trade-offs, the NC55-2RU-FAN-FW= delivers uncompromised reliability, but total cost of ownership demands meticulous lifecycle planning beyond initial hardware procurement.