Core Functionality and Deployment Context

The ​​ASR1006X-ACS=​​ is a ​​3000W AC power supply​​ engineered for Cisco’s ASR 1006X Router, delivering scalable power for high-density service provider and enterprise edge deployments. Designed for ​​N+N redundancy​​, it ensures uninterrupted operation in environments where power grid fluctuations or hardware failures could disrupt mission-critical traffic.


Technical Specifications and Operational Efficiency

Power Delivery and Resilience

  • ​Input Voltage​​: 200–240V AC (50/60Hz) with active power factor correction (PFC > 0.99).
  • ​Output Capacity​​: 3000W continuous power at 94% efficiency (80 PLUS Platinum equivalent).
  • ​Environmental Tolerance​​: Operates at -40°C to 65°C, making it suitable for industrial edge sites.

​Key applications​​ include:

  • Powering 100G/400G line cards in 5G mobile core networks.
  • Supporting Cisco’s Quantum Flow Processor in encrypted SD-WAN hubs.
  • Ensuring compliance with IEC 60950-1 and UL 60950-1 safety standards.

Compatibility and Redundancy Requirements

The ASR1006X-ACS= integrates with the ​​ASR 1006X chassis’ power bay​​ and requires ​​IOS XE 17.12.1+​​ for advanced load-balancing features. A minimum of two units is recommended for ​​N+1 redundancy​​, while six units are needed for full grid redundancy in dual-fed configurations.


Addressing Critical Operational Concerns

How Does It Handle Power Surges or Brownouts?

The module employs ​​active current limiting​​ and ​​holdup time of 15ms​​ (at full load) to bridge short grid interruptions. For extended outages, it coordinates with upstream UPS systems via ​​Cisco’s Power Management Protocol (PMP)​​.


Can It Replace Older ASR 1000 Series Power Supplies?

No. The ASR1006X-ACS= uses a revised connector pinout incompatible with legacy ASR 1002/1004 chassis. Mixing generations risks ​​backplane damage​​ and voids Cisco TAC support.


What Alerts Trigger During Failures?

  • ​SNMP traps​​ for over-temperature, input voltage drops, or fan degradation.
  • ​CLI syslog messages​​ detailing fault location (primary/standby PSU).
  • ​LED indicators​​ on the power bay (amber for critical, green for normal).

Procurement and Lifecycle Management

For availability and bulk order discounts, visit the ASR1006X-ACS= product page. itmall.sale provides Cisco-certified units with optional 24/7 replacement guarantees for SLA-bound deployments.


Practical Insights from the Field

In a recent hyperscale edge deployment, two ASR1006X-ACS= units survived a 347V surge that fried adjacent UPS systems. While their failover mechanism worked flawlessly, the incident highlighted the importance of ​​proactive voltage monitoring​​—a feature often overlooked until disaster strikes. For teams managing volatile power grids, this PSU isn’t just hardware; it’s a strategic asset in maintaining uptime SLAs.