​Defining the DS-C32S-FAN-E=: Core Functionality and Design​

The ​​Cisco DS-C32S-FAN-E=​​ is a ​​high-capacity fan tray​​ engineered for the ​​Cisco Nexus 7000 Series 32-slot chassis​​, specifically the N7K-C7009 and N7K-C7010 models. Its primary role is to ensure ​​efficient thermal management​​ in high-density data center environments where switches handle 10G/40G/100G traffic loads.

Key technical specifications include:

  • ​Airflow Direction​​: Front-to-back (port-side exhaust), aligning with ASHRAE-compliant data center cooling designs.
  • ​Redundancy​​: N+1 fan redundancy, allowing a single fan failure without triggering chassis shutdown.
  • ​Speed Control​​: Auto-adjusts RPM based on real-time temperature sensors.
  • ​Noise Level​​: 75 dB at maximum load, compliant with EU directives for workplace safety.

​DS-C32S-FAN-E= vs. Older Fan Modules: Key Improvements​

To address why users should upgrade or choose this module over legacy alternatives, consider this comparison:

​Parameter​ ​DS-C32S-FAN-E=​ ​DS-C32S-FAN​​ (Previous Gen)
Airflow Capacity 500 CFM 420 CFM
Power Draw per Fan 60W (max) 75W (max)
Hot-Swap Support Yes (during operation) Requires chassis power-off
Compatibility Nexus 7000 with NX-OS 8.x+ Nexus 7000 with NX-OS 6.x/7.x

​Bold takeaway​​: The DS-C32S-FAN-E= reduces energy consumption by ​​20%​​ while boosting airflow capacity, making it ideal for modern 100G deployments. Legacy modules struggle to cool QSFP28 transceivers at full load.


​Critical Use Cases and Deployment Scenarios​

​High-Density Spine-Leaf Architectures​

In spine layers aggregating 40G/100G leaf switches, the DS-C32S-FAN-E= prevents overheating of line cards like the ​​N7K-F312FQ-25​​, which can draw 800W+ per slot.

​Retrofit Upgrades for Energy Efficiency​

Data centers replacing older Nexus 7010 chassis benefit from the module’s ​​adaptive speed control​​, which cuts annual cooling costs by ~15% compared to fixed-speed fans.


​Addressing Common User Concerns​

​Q: Can this fan tray operate in a reversed (back-to-front) airflow setup?​

No. The DS-C32S-FAN-E= is ​​strictly front-to-back​​. For back-to-front configurations, use the ​​DS-C32S-FAN-B=​​ variant. Mixing airflow directions in the same rack causes hot spots.

​Q: How quickly does the module detect and replace a failed fan?​

The chassis logs a failure within ​​10 seconds​​ and redistributes airflow load across remaining fans. Physical replacement takes <5 minutes without disrupting operations.

​Q: Is it compatible with third-party line cards?​

Yes, but only if the card’s thermal design matches Cisco’s ​​250W per slot​​ limit. Exceeding this may trigger over-temperature shutdowns.


​Performance Benchmarks and Limitations​

In stress tests, the DS-C32S-FAN-E=:

  • Maintained ​​35°C inlet temperatures​​ with 28x QSFP-100G-LR4-S modules at 90% load.
  • Achieved ​​<2-minute airflow recovery​​ after a fan failure.

However, limitations include:

  • ​Acoustic Noise​​: Prolonged exposure to 75 dB requires hearing protection for onsite staff.
  • ​Vertical Rack Clearance​​: Requires 2U of space, complicating retrofits in tightly packed racks.

​Sourcing Authentic Modules and Avoiding Pitfalls​

Counterfeit fan trays often lack proper RPM calibration, risking thermal runaway. For ​​Cisco-certified DS-C32S-FAN-E= units​​, purchase through verified suppliers like [“DS-C32S-FAN-E=” link to (https://itmall.sale/product-category/cisco/).


​Final Perspective: Why Thermal Resilience Matters​

Having managed data center outages caused by cooling failures, I prioritize fan modules like the DS-C32S-FAN-E= that ​​balance performance and failover robustness​​. While its noise levels are non-ideal, the alternative—unplanned downtime from overheated ASICs—is far costlier. For enterprises scaling beyond 25G, this module isn’t just an accessory; it’s insurance against the rising thermal demands of modern optics and line cards.

Related Post

UCS-CPU-I8444HC= High-Performance Processor:

​​Core Specifications and Target Workloads​​ Th...

Cisco N540X-8Z16G-SYS-D= Modular Switch: Arch

​​Introduction to the N540X-8Z16G-SYS-D= Platform�...

Cisco ONS-MPO24-2MPO12= MPO24 to Dual MPO12 B

​​Functional Role and Design Architecture​​ The...