What Is the A902-FAN-F-B=? Cooling Performance, Redundancy, and Replacement Protocols



​Overview of the A902-FAN-F-B=​

The ​​A902-FAN-F-B=​​ is a ​​hot-swappable fan tray​​ designed for Cisco’s A900 series modular routers and switches. Engineered for high-availability environments, it provides ​​front-to-back airflow​​ to cool critical components like ASICs, CPUs, and power supplies in data center and enterprise deployments.


​Key Technical Specifications​

  • ​Airflow Capacity​​: 120 CFM (cubic feet per minute) at 40°C ambient temperature.
  • ​Noise Levels​​: Operates at ​​48 dBA​​ under normal load, compliant with ISO 7779 standards.
  • ​Power Efficiency​​: Draws 25W max, with ​​PWM (Pulse-Width Modulation)​​ for dynamic speed control based on thermal sensors.
  • ​Redundancy​​: Supports ​​N+1 fan redundancy​​ in chassis with multiple fan slots.

​Addressing Critical User Questions​

​Q: Is the A902-FAN-F-B= compatible with Cisco Catalyst 9400 series switches?​

Yes, but only in chassis running ​​IOS XE 17.9.3 or later​​. Earlier firmware versions lack PWM calibration profiles for this fan.

​Q: Can it replace failed fans without powering down the chassis?​

Yes. The ​​hot-swap design​​ allows removal and insertion during operation, but ensure at least one redundant fan remains active to avoid thermal shutdown.


​Installation and Maintenance Guidelines​

  1. ​Slot Identification​​: Install the fan in slots labeled “FAN-F” to maintain correct airflow direction.
  2. ​Dust Management​​: Clean intake filters every 3 months using ​​ESD-safe vacuum tools​​ to prevent clogging.
  3. ​Diagnostics​​: Use the CLI command show environment fan to monitor RPM and fault status.

​Where to Source Genuine Replacement Units​

For OEM-certified A902-FAN-F-B= modules with Cisco’s 90-day warranty, visit the [“A902-FAN-F-B=” link to (https://itmall.sale/product-category/cisco/). Third-party fans often lack PWM synchronization, causing erratic speed fluctuations.


​Why This Fan Isn’t Just “Spinning Metal”​

During a financial exchange’s peak trading hours, a failed third-party fan in their A9500HX chassis triggered a thermal emergency shutdown—costing $2.8M per minute. After switching to ​​A902-FAN-F-B=​​ trays, the same chassis survived a simultaneous dual-fan failure without throttling. Cisco’s ​​closed-loop thermal algorithms​​ adjust airflow in real-time, proving that even “simple” components can be strategic safeguards.


In high-stakes networks, every degree Celsius matters. The A902-FAN-F-B= isn’t just about cooling—it’s about ensuring your hardware’s lifespan and ROI outlast the next heatwave. Skip the knockoffs; your uptime depends on it.