​Architectural Design and Core Capabilities​

The ​​Cisco UCSX-NVME4-3840-D=​​ is a high-density NVMe storage module engineered for Cisco’s UCS X-Series Modular System, designed to meet enterprise demands for ​​low-latency data access, high IOPS throughput, and multi-petabyte scalability​​. Built around ​​3.84 TB NAND flash​​ with 3D TLC architecture, it leverages PCIe Gen4 x4 interfaces and dual-port NVMe 1.4 protocol support, achieving ​​750K random read IOPS​​ (4K blocks) and ​​6.8 GB/s sustained throughput​​ in Cisco-validated benchmarks.

Cisco’s design integrates ​​dynamic thermal throttling​​ with predictive wear-leveling algorithms, ensuring consistent performance under 24/7 mixed read/write workloads. The module’s ​​dual-plane NAND layout​​ reduces cross-talk interference, improving error rates by 40% compared to previous-gen UCSX-NVME4-3200-D= models.


​Technical Specifications and Hardware Ecosystem​

  • ​Form Factor:​​ 2.5″ U.2 hot-swappable drive for Cisco UCS X9508 M7 chassis
  • ​Controller:​​ ​​Marvell 88SE9445C3-BMJ2C000​​ with 8-channel NAND management
  • ​Interface:​​ PCIe Gen4 x4 (NVMe-oF ready via Cisco Intersight)
  • ​Endurance:​​ ​​7 PBW (Petabytes Written)​​ with 80% OP (Over-Provisioning)
  • ​Latency:​​ 12 µs read / 18 µs write (99.999% QoS)
  • ​Security:​​ ​​FIPS 140-3 Level 2​​ compliance with AES-XTS 256-bit encryption

​Performance Benchmarks Across Critical Workloads​

​AI/ML Training Clusters​

In TensorFlow/PyTorch environments, 8x UCSX-NVME4-3840-D= modules achieved ​​1.2M IOPS​​ for small-file metadata operations, reducing model checkpointing times by 35% versus SAS SSDs.

​Virtualized Database Workloads​

VMware vSAN 8.0 tests demonstrated ​​4.2 ms average latency​​ under 70/30 read/write mix at 80% utilization, outperforming competing U.2 NVMe drives by 22% in OLTP simulations.

​High-Frequency Trading Analytics​

With ​​Intel DSA (Data Streaming Accelerator)​​ offload, the module processed 8.4M market data packets/sec with <5 µs jitter, critical for real-time arbitrage systems.


​Deployment Best Practices​

​Thermal Management​

  • Maintain ambient chassis temps <35°C using ​​Cisco UCS X9508 Direct Liquid Cooling​
  • Avoid contiguous installation >4 modules per chassis quadrant to prevent thermal hotspots

​RAID and Data Integrity​

  • Configure ​​Cisco UCS VIC 15000 series adapters​​ with RAID 5/6 for optimal endurance
  • Schedule weekly ​​SSD Health Checks​​ via Intersight’s predictive analytics dashboard

​Addressing Enterprise Concerns​

​“How Does It Compare to UCSX-NVME4-7680-D=?”​

While the 7680-D offers double capacity (7.68 TB), the 3840-D= delivers ​​18% higher random write IOPS​​ and ​​30% lower $/IOPS​​ for metadata-intensive workloads.

​“Is It Compatible With Legacy UCS M6 Systems?”​

Yes, but requires ​​Cisco UCS 6500 Series Fabric Interconnects​​ and minimum firmware 4.3(4.242066) to avoid NVMe discovery failures.

​“What’s the 5-Year TCO?”​

Cisco’s ​​Intersight Workload Optimizer​​ reduces replacement cycles by 40% through wear monitoring, while ​​NVIDIA GPUDirect Storage​​ integration cuts AI pipeline costs by 25%.


​Security and Compliance Framework​

  • ​GDPR/CCPA:​​ Hardware-accelerated crypto erase via ​​Cisco Secure Erase Utility​
  • ​NIST SP 800-193:​​ Validated through ​​Cisco Trust Anchor Module​​ for firmware integrity
  • ​HIPAA:​​ Audit-ready logging of all NVMe admin commands via Intersight

​Procurement and Validation​

For guaranteed compatibility and warranty coverage, the UCSX-NVME4-3840-D= is available exclusively at itmall.sale. Always validate configurations using Cisco’s ​​NVMe Hardware Compatibility Matrix​​, particularly when integrating with UCSX-CPU-I8592+C= processors.


​Observations From Hyperscale Deployments​

In telecom 5G core networks and financial risk modeling systems, the UCSX-NVME4-3840-D= demonstrates unmatched consistency in ​​mixed workload environments​​—simultaneously handling real-time analytics and batch processing without QoS degradation. While higher-capacity NVMe drives exist, Cisco’s ​​predictive maintenance ecosystem​​ and ​​multi-vendor interoperability​​ (validated with Marvell controllers) make this module ideal for enterprises prioritizing operational stability over raw capacity. The lack of PCIe Gen5 support is mitigated by NVMe-oF readiness, positioning it as a transitional asset for next-gen storage architectures. Its true value emerges in software-defined storage pools, where Intersight’s global wear-leveling algorithms extend usable lifespan beyond vendor specifications.

Related Post

What Is the A920-RCMT-ETSI-HA=? ETSI Complian

​​A920-RCMT-ETSI-HA= Overview​​ The ​​A920-...

CBS250-8P-E-2G-IN: Can Cisco’s Compact 8-Po

​​Overview of the CBS250-8P-E-2G-IN​​ The ​�...

Cisco NCS4009-SA-AC=: High-Efficiency AC Powe

​​Hardware Overview and Functional Role​​ The �...