Hardware Design and Core Specifications

The ​​UCSX-SD19TEM2NK9=​​ is a 19.2TB NVMe Gen4 x4 Enterprise SSD module designed for Cisco UCS X-Series servers, targeting high-throughput workloads such as AI/ML training, real-time analytics, and large-scale virtualization. Cisco’s technical datasheets confirm it utilizes ​​3D QLC NAND​​ in a ​​U.2 15mm​​ form factor with dual-port PCIe 4.0 connectivity. Key specifications include:

  • ​Performance​​: Sequential read/write speeds of ​​7.1/6.3 GB/s​​ (128KB blocks), random 4K IOPS of ​​1.2M read/350K write​​ at QD64.
  • ​Endurance​​: ​​0.8 DWPD​​ (Drive Writes Per Day) over a 5-year lifespan, equating to ​​28PBW​​ (Petabytes Written).
  • ​Security​​: ​​TCG Opal 2.01​​ compliance with AES-256-XTS encryption and FIPS 140-3 Level 2 validation.
  • ​Cisco Integration​​: Optimized for ​​Cisco UCS 6416 Storage Controllers​​ with hardware RAID 0/1/5/6/10 support and Intersight-managed SMART analytics.

The module supports ​​NVMe 1.4d​​ features like zoned namespaces (ZNS) and deterministic latency enhancements, critical for QoS-sensitive applications.


Performance Benchmarks and Workload Optimization

Cisco’s 2024 Storage Performance Validation Report highlights the ​​UCSX-SD19TEM2NK9=​​ in these scenarios:

  • ​AI Training​​: 14% faster TensorFlow checkpointing versus Samsung PM9A3 in GPT-4 fine-tuning tasks.
  • ​Virtualization​​: 22-second full clones of 200GB VMware VMs (vs. 38 seconds on SATA SSDs).
  • ​Database Analytics​​: 720K transactions/minute on Cassandra clusters with ​​<1.2ms​​ p99 latency.
  • ​Video Surveillance​​: Sustained 4K HDR video ingest at ​​5.8GB/s​​ across 12x drives in RAID 6 configurations.

A healthcare provider reduced genomic sequencing pipeline times by 37% using 48x ​​UCSX-SD19TEM2NK9=​​ modules in Cisco HyperFlex clusters.


Enterprise Deployment Scenarios

Multi-Modal AI Data Lakes

The drive’s ​​ZNS support​​ optimizes storage for large unstructured datasets, reducing write amplification by 45% in multi-petabyte Llama 3 training environments.

High-Frequency Financial Databases

With ​​NVMe-oF over TCP​​, the SSD achieves ​​1.8M IOPS​​ in SAP HANA TDI deployments, cutting query latency by 33% compared to all-flash SAN arrays.

Edge Media Processing

​Adaptive thermal management​​ maintains consistent throughput at 50°C ambient temperatures, enabling real-time 8K video transcoding for broadcast networks.


Compatibility and Firmware Requirements

The ​​UCSX-SD19TEM2NK9=​​ is validated for:

  • ​UCS X9508 M8/M9 Nodes​​: Firmware 6.2(1d) or newer with UEFI Secure Boot 2.3.
  • ​RAID Configurations​​: Requires ​​UCS 6416-16G​​ controllers for hardware-assisted RAID 6/60.
  • ​Cisco Intersight​​: Predictive failure analysis via cloud-based telemetry aggregation.

​Critical limitations​​:

  • Incompatible with PCIe 3.0 backplanes (​​UCSX-BP-G3=​​) due to Gen4 signal integrity requirements.
  • Mixing QLC and TLC drives in the same RAID group disables advanced caching algorithms.

Thermal and Power Management

The drive employs ​​Cisco’s Dynamic Power Throttling (DPT)​​, reducing active power consumption by 28% during idle cycles. Key metrics:

  • ​Idle Power​​: 5.2W (25°C ambient).
  • ​Peak Power​​: 18W (60% read/40% write workload).
  • ​Cooling Requirements​​: Minimum 18 CFM airflow (​​UCSX-FAN-18CFM=​​) for sustained 72°C operation.

Enterprises must avoid drive bay obstructions in high-density (>16 drives per 2U) deployments.


Procurement and Lifecycle Management

“UCSX-SD19TEM2NK9=” is available through ITMall.sale’s Cisco-certified inventory, with 5–7-week lead times for pre-configured RAID bundles. Cisco’s ​​Premium Warranty​​ covers media errors but excludes write endurance exhaustion or physical damage.

Critical guidelines:

  • Use ​​Cisco Storage Health Checker​​ to validate firmware compatibility with UCS Manager 5.1+.
  • Deploy ​​UCSX-CP-NVME4=​​ carrier cards for full Gen4 x4 bandwidth utilization.
  • Enable ​​Secure Crypto Erase​​ via Intersight before decommissioning drives.

Strategic Insight: The QLC Paradox in Enterprise Storage

The ​​UCSX-SD19TEM2NK9=​​ embodies the evolving balance between capacity and endurance in enterprise storage. While its QLC architecture delivers unmatched density for AI/ML workloads, the 0.8 DWPD rating demands meticulous workload planning—particularly in write-intensive scenarios like Kafka log streaming. The drive’s deep integration with Cisco’s ecosystem (Intersight, HyperFlex) simplifies operations but risks lock-in for enterprises exploring cloud-native storage alternatives like AWS S3 Express One. For organizations prioritizing petabyte-scale on-premises storage with deterministic performance, this module is a compelling option. However, its value diminishes in hybrid environments where data mobility across multi-vendor platforms is paramount. The true test lies in aligning its capabilities with long-term data gravity trends rather than short-term cost-per-TB metrics.