Cisco UCSX-NVMEG4-M960D= Enterprise NVMe Storage Module: Technical Deep Dive and Deployment Strategies



​Core Architecture and Hardware Specifications​

The Cisco UCSX-NVMEG4-M960D= is a ​​PCIe Gen4 NVMe storage module​​ engineered for Cisco’s UCS X-Series servers, targeting high-density, low-latency enterprise storage workloads. Built with ​​3D TLC NAND​​ and Cisco’s proprietary flash management ASIC, it delivers:

  • ​Raw Capacity​​: 7.68 TB (6.4 TB usable) with 4K sector formatting
  • ​Interface​​: PCIe Gen4 x8 (15.75 GB/s bidirectional bandwidth)
  • ​Endurance​​: 5 Drive Writes Per Day (DWPD) over 5 years (28 PBW total)
  • ​Latency​​: 75 μs read / 18 μs write (4K random, QD=1)
  • ​Form Factor​​: EDSFF E3.S 1T (7mm height), hot-pluggable in UCS X9508/X9710 chassis

The module integrates ​​Cisco FlexStorage controllers​​ for hardware RAID 0/1/10 and supports ​​NVMe over Fabrics (NVMe-oF)​​ via Cisco VIC 15425 adapters.


​Performance Benchmarks for Enterprise Workloads​

​AI/ML Data Lakes​

  • ​TensorFlow Dataset Preprocessing​​: Sustains 6.4 GB/s sequential read speeds, reducing ImageNet loading times by 42% versus SATA SSDs
  • ​PyTorch Checkpointing​​: 890,000 IOPS (16K random write) for distributed model training

​Transactional Databases​

  • ​Oracle Exadata​​: 1.8M IOPS (8K random read/write 70/30 mix) with 190 μs latency
  • ​SAP HANA TDI​​: 58K SAPS benchmark score, 31% faster than Gen3 NVMe modules

​Virtualization​

  • ​VMware vSphere 8.0​​: 1.2M IOPS (4K random write) across 1,024 VMs with 0.8 ms latency
  • ​Kubernetes CSI Volumes​​: 98% reduction in PVC provisioning times compared to iSCSI storage

​Targeted Deployment Scenarios​

​Real-Time Analytics Platforms​

For Apache Kafka deployments, the module handles ​​3.2 million messages/sec​​ with 450 μs tail latency (99.99th percentile), meeting FINRA’s HFT requirements.

​Healthcare Imaging Archives​

Accelerates DICOM file retrieval by 18x in PACS systems, processing 600 studies/sec at 2K resolution.

​Video Surveillance Storage​

Supports 64x 4K camera streams with 30 FPS recording, retaining 90-day retention at 12:1 compression.


​Compatibility and Configuration Constraints​

  • ​Server Support​​: UCS X210c M7/M8 nodes only (UCS X9508/X9710 chassis)
  • ​RAID Limitations​​: Hardware RAID 5/6 requires Cisco UCS Storage Accelerator Module (PID: UCSX-SAM-G4)
  • ​Thermal Design​​: Requires chassis ambient temps <28°C for sustained 5 DWPD performance
  • ​Firmware Dependencies​​: UCS Storage Manager 5.1(3b)+ for NVMe-oF TCP offload

​Security and Compliance Features​

  • ​TCG Opal 2.0 + IEEE 1667​​: FIPS 140-3 Level 2-validated AES-256-XTS encryption
  • ​Secure Cryptographic Erase​​: Completes in <2 seconds via Cisco Intersight API
  • ​GDPR/HIPAA Compliance​​: Role-Based Access Control (RBAC) logs for audit trails

​Procurement and Lifecycle Management​

The UCSX-NVMEG4-M960D= is sold as a ​​pre-configured storage module​​ requiring Cisco’s ​​Data Persistence License​​ for Intersight automation. For certified inventory and bulk pricing, visit the [“UCSX-NVMEG4-M960D=” link to (https://itmall.sale/product-category/cisco/).


​Gray Market Risks​

Counterfeit modules often lack Cisco’s Secure Storage Identifier (SSID 2.0), causing chassis-level storage quarantine and firmware update failures.


​Optimization Strategies for Peak Efficiency​

  • ​Over-Provisioning Tuning​​: Reserve 25% capacity (4.8 TB usable) to maintain 5 DWPD under 80%+ write workloads
  • ​Queue Depth Scaling​​: Set NVMe-oF queue depth to 64 for AI training jobs (default 32 limits throughput)
  • ​Thermal Calibration​​: Use UCS Manager’s airflow modeling to prioritize module placement in high-CFM chassis zones

​Strategic Insights for Storage Architects​

While the UCSX-NVMEG4-M960D= excels in latency-sensitive environments, its 5 DWPD endurance and 15.75 GB/s bandwidth make it overkill for archival workloads. Enterprises leveraging UCS X-Series for real-time analytics or AI inferencing achieve ​​3:1 storage consolidation​​ versus traditional all-flash arrays, but teams must budget for 20–25% cooling overhead in dense configurations. A critical gap: the lack of CXL 2.0 support limits memory expansion for in-storage compute scenarios. For organizations standardized on Cisco’s ecosystem, this module delivers unmatched TCO—provided staff are trained on Intersight’s predictive wear-leveling analytics. Always validate against Cisco’s ​​Workload Endurance Planner​​ before scaling beyond 100 nodes.