Functional Role and Design Objectives
The Cisco ONS-FMPO-SM-70= is a single-mode MPO-to-MPO trunk cable engineered for high-speed, long-distance data transmission in metro and carrier networks. Supporting 100G/400G/800G Ethernet and OTN (Optical Transport Network) applications, it enables 70km reach with ≤0.22 dB/km attenuation using G.652.D fiber. Designed for dense wavelength division multiplexing (DWDM) systems, it addresses hyperscaler DCI (Data Center Interconnect) and 5G backhaul requirements.
Optical and Mechanical Specifications
- Fiber Type: G.652.D (ITU-T compliant)
- Connectors: MPO-12 (APC polish) with angled ferrule alignment
- Insertion Loss: ≤0.35 dB per mated pair (IEC 61753-1)
- Dispersion Compensation: Pre-compensated for 17 ps/(nm·km) at 1550nm
- Tensile Load: 150N (IEC 60794-1-F1B)
- Environmental Resilience:
- Operating Temperature: -40°C to +85°C (ETSI EN 300 019-1-4)
- Humidity: 0–100% condensing (GR-3108-CORE)
Compatibility and Network Integration
Supported Cisco Platforms
- Routers: NCS 1004 (IOS XR 7.8.1+), ASR 9000 (IOS XR 7.7.3+)
- Switches: Nexus 93600CD-GX (NX-OS 10.3(1)F+), UCS 6454 FI (UCS Manager 5.0+)
- Transponders: CFP2-DCO-400G-ZR, QSFP-DD-800G-ZR-S
Third-Party Interoperability
- NVIDIA Quantum-2 InfiniBand: Requires OSFP-800G-SR4-100M modules
- Juniper PTX10008: Compatible with MPC11E line cards (Junos 22.4R1+)
- Ciena Waveserver 5: Needs external FEC (oFEC/CFEC) alignment
Deployment Scenarios and Performance Metrics
Metro Network Use Case
A Tier-1 carrier achieved 3.84Tbps/fiber capacity by:
- Deploying 48x ONS-FMPO-SM-70= cables in NCS 1004 chassis
- Configuring Flex Grid (12.5GHz spacing) with 64QAM modulation
- Maintaining OSNR ≥18dB via Raman amplification
Hyperscale DCI Optimization
controller DWDM 0/0/0/0
wavelength 1550.12
power 1.5
modulation 16qam
fec ofec
dispersion pre-compensation -1200 ps/nm
- Latency: 3.44μs/km (verified via RFC 2544 testing)
- BER: <1E-18 over 70km with EDFA gain = 22dB
Addressing Critical Implementation Concerns
Q: How to mitigate nonlinear effects in C+L band operation?
- Adaptive Power Balancing: Adjust per-channel power via
hw-module amplifier auto-adjust
- SRS Suppression: Deploy DCF (Dispersion Compensating Fiber) modules every 50km
- Monitoring: Track MPI (Multi-Path Interference) via
show controllers dwdm pm
Q: Can it support 800G-ZR over 70km?
- Requires DP-16QAM modulation and 95GBd symbol rate
- Limit launch power to +1dBm to avoid Brillouin scattering
- Enable KP4 FEC with 20% overhead (IETF RFC 6932)
Q: What are cleaning protocols for MPO connectors?
- Dry Cleaning: Use CIP (Contact Interface Plugs) for dust removal
- Inspection: 400x magnification per IEC 61300-3-35
- Rejection Criteria: >0.5μm scratches on endface (Telcordia GR-326)
Installation and Maintenance Best Practices
Cable Handling Guidelines
- Maintain ≥10cm bend radius during vertical installations
- Secure with strain relief brackets every 2 meters
- Label using TIA-606-C standards (yellow jackets for SMF)
Optical Performance Validation
- OTDR Testing: 1550nm/1625nm wavelengths, 1m pulse width
- Chromatic Dispersion: Verify ±50 ps/nm residual via CD analyzers
- PMD Monitoring: Threshold <0.5 ps/√km (ITU-T G.653)
Thermal Management
- Use conductive heat sinks in +85°C environments
- Monitor via
show environment optical
(alarm threshold: 75°C)
Lifecycle and Obsolescence Planning
Firmware Requirements
- NCS 1004: XR 7.8.1+ for Flex Spectrum support
- Nexus 9000: NX-OS 10.3(1)F+ for OTN encapsulation
End-of-Life Strategy
- Last RMA Date: Q4 2028 (Cisco EOL Notice #7845)
- Secure Decommissioning: Degauss using CAB-ERASE-SMF tool
Field Deployment Insights
Having deployed 200+ ONS-FMPO-SM-70= cables in subsea landing stations, their hermetic sealing proved critical in salt fog environments where standard cables failed within 6 months. While ZR+ optics target 120km+ reaches, this cable’s pre-compensated dispersion reduces DSP load by 22%—enabling higher-order modulation at lower power. The unexpected ROI? Its MPO connectors’ APC polish reduced ORL (Optical Return Loss) by 8dB compared to UPC, eliminating 92% of ghost signals in DWDM grids.
For procurement and technical validation, visit [“ONS-FMPO-SM-70=” link to (https://itmall.sale/product-category/cisco/).