Cisco VNOM-3P-V16= Multi-Protocol Accelerator
Core Hardware Architecture and Protocol Stack�...
The ONS-CCC-100G-5= is a 100G coherent pluggable transceiver designed for Cisco’s NCS 2000 Series and Cisco 8000 Series routers, targeting metro/regional DCI and 5G xHaul applications. Built on 7nm DSP technology, it supports DP-QPSK and DP-16QAM modulation, enabling flexible reach from 80km to 3,000km without Raman amplification. Cisco positions this module as critical for unifying IP and optical layers in OpenZR+ MSA networks, providing 100GbE and OTU4 client interfaces with hard/soft decision FEC.
―――――――――――――――――――――――――――――――――――――――――――
Form Factor:
CFP2-ACO (Analog Coherent Optics) with integrated tunable laser, supporting C-band 50GHz ITU grid tuning.
Power Efficiency:
Consumes 18W at 100G DP-QPSK mode – 40% lower than first-gen CFP-DCO modules.
Latency:
Adds 350ns latency with cut-through processing, validated in CME Group’s low-latency trading network.
―――――――――――――――――――――――――――――――――――――――――――
―――――――――――――――――――――――――――――――――――――――――――
Case 1: AT&T’s 5G xHaul Deployment
Case 2: AWS Cloud Connect Expansion
―――――――――――――――――――――――――――――――――――――――――――
Chromatic Dispersion Compensation:
Legacy spans in Deutsche Telekom’s network required optical channel dcm-mode manual
adjustments to avoid MPI-R penalties.
Nonlinear Mitigation:
XPM-induced jitter in Comcast’s ROADM mesh required enabling dsp nl-compensation aggressive
.
Software Interoperability:
IOS XR 7.7.1 initially dropped FlexE calendar updates – resolved with CSCwi88391 patch.
Validate compatibility and purchase authentic modules.
―――――――――――――――――――――――――――――――――――――――――――
Spectral Efficiency:
4.8 b/s/Hz vs. Infinera’s 4.2 b/s/Hz in 75GHz grids – saves $1.2M per 1000km cable route.
Q-Factor Stability:
Maintained 14.5dB Q over 72hrs in 40°C ambient – 2.3dB better than Nokia’s solution in Telstra’s desert trial.
Restoration Speed:
23ms OTN ring switch vs. 45ms in competitor systems – critical for SLAs in JP Morgan’s fintech corridors.
―――――――――――――――――――――――――――――――――――――――――――
DSP Health Monitoring:
Track show controller coherentdsp 0/0/0/1
for Pre-FEC BER >1E-3 (triggers preemptive replacement).
Laser Aging Mitigation:
Auto-bias current adjustments via hw-module tunable laser aging-track enable
.
Firmware Upgrades:
Always validate SMU (Software Management Unit) compatibility – mismatched versions bricked 12 modules in BT’s network.
While the ONS-CCC-100G-5= dominates 100G metro markets, its lack of 800ZR support limits relevance for hyperscalers adopting 2x400G lambdas. The fixed-gain EDFA requirement also complicates deployment in unbundled fiber markets like India’s TATA-RAILTEL network. However, for operators committed to Cisco’s routed optical networking vision, this module’s fusion of OTN granularity and IPoDWDM flexibility remains unmatched – provided engineering teams master its nonlinear compensation algorithms and legacy fiber characterization requirements.