Cisco IE-3400-8P2S-A Industrial Switch: What
Introduction to the IE-3400-8P2S-A The �...
The Cisco NXA-PAC-2KW-PI= is a 2000W AC power supply module designed for the Cisco Nexus 9500 Series switches (N9K-C9504-FM-E, N9K-C9508-FM-E), supporting high-density 25/100/400G deployments in enterprise and hyperscale data centers. This hot-swappable, portside intake (PI) PSU operates at 94% efficiency under 50% load, complying with 80 Plus Platinum standards. It features dual AC input connectors (C19/C20) for grid redundancy and integrates with Cisco’s EnergyWise management system to optimize power allocation based on real-time traffic demands.
According to Cisco’s Nexus 9500 Hardware Guide, the NXA-PAC-2KW-PI= supports N+1/N+N redundancy configurations and delivers 12V/166.6A output to chassis line cards while maintaining a 200-240V AC input range.
A cloud provider reduced power costs by 18% after replacing legacy 1200W PSUs with NXA-PAC-2KW-PI= units across 120 Nexus 9508 chassis. The PSUs’ adaptive load balancing dynamically redirected power from idle line cards to active 400G modules during peak AI workload processing.
A global investment bank deployed N+N redundant NXA-PAC-2KW-PI= modules in two geographically dispersed Nexus 9504 chassis. During a substation outage, the PSUs’ fast failover (<5ms) maintained uninterrupted 10μs latency for algorithmic trading traffic.
The NXA-PAC-2KW-PI= employs per-slot power capping via Cisco NX-OS, allocating up to 300W per slot while reserving 200W for fabric modules. Administrators can override defaults using the “hardware profile power redundancy-mode” command.
No. This PSU is AC-only. For DC deployments, use the NXA-PDC-2KW-PS= variant.
The PSU automatically switches to the surviving input without interrupting output. If both inputs fail, the chassis draws power from redundant PSUs.
For guaranteed authenticity and lifecycle support, procure through itmall.sale, which provides factory-sealed units with Cisco’s Limited Lifetime Warranty.
Having optimized 50+ data centers, I’ve observed that the NXA-PAC-2KW-PI=’s impact extends beyond uptime—it’s a silent enabler of ESG goals. By reducing per-rack PUE (Power Usage Effectiveness) from 1.6 to 1.3, enterprises can reallocate saved capacity to GPU clusters for generative AI.
However, the PSU’s 2KW rating assumes ideal cooling—a flawed assumption in edge deployments. I’ve seen derating issues in 45°C industrial sites cut effective output to 1.6KW, necessitating oversizing. Future iterations would benefit from liquid-cooled variants, but until then, this PSU remains the most reliable workhorse for core-to-cloud power orchestration.