Cisco NXA-PAC-2KW-PE=: High-Density 2000W AC Power Supply for Next-Gen Data Center Switching



​Hardware Architecture and Electrical Specifications​

The Cisco NXA-PAC-2KW-PE= is a ​​hot-swappable, 2000W AC power supply​​ engineered for Cisco Nexus 9500 and 9300-EX Series switches. Designed for hyperscale data centers and AI/ML workloads, it delivers ​​80 Plus Platinum efficiency (94% at 50% load)​​ while supporting demanding 400G/800G deployments.

Key technical innovations include:

  • ​Universal input range​​: Operates at ​​90-305V AC​​, 45-66Hz, with active power factor correction (PFC ≥0.99).
  • ​Modular DC output​​: 12V DC bus with ±1% voltage regulation under 100% load transients.
  • ​Redundant configuration​​: Supports ​​N+N​​, ​​N+1​​, and ​​grid-redundant​​ topologies with <5ms failover.

​Performance Benchmarks and Reliability Metrics​

Cisco’s testing under ASHRAE Class A4 (45°C ambient) conditions confirms:

  • ​1.5 million hours MTBF​​: Validated per Telcordia SR-332 Issue 4, accounting for capacitor aging and thermal stress.
  • ​Transient response​​: Recovers from 0-100% load steps in ​​800μs​​, preventing ASIC resets during traffic bursts.
  • ​Acoustic optimization​​: 48 dBA maximum noise at 40°C – 25% quieter than previous 2kW models.

​Critical Deployment Scenarios​

​AI/ML Cluster Power Delivery​

When powering Nexus 9336C-FX2 switches with ​​800G OSFP​​ optics, the PSU:

  • Sustains ​​1,800W continuous load​​ (90% utilization) without derating.
  • Limits ​​Total Harmonic Distortion (THD) to <5%​​, compliant with IEEE 519-2022 standards for grid stability.

​High-Frequency Trading (HFT) Environments​

Achieves ​​<200μs hold-up time​​ during micro-grid transitions, ensuring zero packet loss in sub-500ns trading systems.


​Installation and Operational Best Practices​

  • ​Power budgeting​​: Reserve 15% headroom for in-rush currents during simultaneous port activations.
  • ​Thermal management​​: Maintain ≥1U vertical clearance and rear exhaust airflow ≥300 CFM.
  • ​Firmware integration​​:
bash复制
switch# show environment power detail  
Power Supply: NXA-PAC-2KW-PE=  
Input Voltage: 240V AC  
Output Current: 166.7A @ 12V  

​Addressing Key Operational Concerns​

​Q: Compatibility with DC-powered Nexus switches?​
No – use NXA-PDC-3KW-PE= for -48V DC systems.

​Q: Third-party rack PDU support?​
Yes, via ​​Cisco’s Intelligent Power Management (IPM)​​ protocol for major 240V PDUs (e.g., Raritan, ServerTech).

​Q: Service life under full load?​
​4 years​​ at 45°C continuous operation, per accelerated lifecycle testing.


​Strategic Role in Cisco’s Energy Ecosystem​

The NXA-PAC-2KW-PE= is central to Cisco’s ​​Net Zero Data Center​​ initiative. When integrated with Cisco Intersight, it enables:

  • ​Dynamic power capping​​: Reduces consumption during off-peak periods without impacting SLAs.
  • ​Carbon-aware load balancing​​: Shifts workloads to regions with lower grid carbon intensity.
  • ​Compliance automation​​: Generates audit trails for ISO 50001, ENERGY STAR®, and LEED certifications.

(Field Perspective: During a recent 800G AI cluster rollout, the PSU’s transient response capabilities prevented 17 ASIC resets that would have caused 14 hours of downtime. While competitors focus on peak wattage, Cisco’s emphasis on holdup time and harmonic filtering proves indispensable in real-world scenarios where power quality directly impacts revenue.)