dnx_nh_unilist_install_multipath: Failed to create shadow obj 0x20017ff0 for NH 766(FEC 0x2000109f) unilist nh 2097161. Error -14(No resources for operation)


Understanding the DNX_NH_UNILIST_INSTALL_MULTIPATH Error: A Comprehensive Guide

The DNX_NH_UNILIST_INSTALL_MULTIPATH error is a complex issue that can occur in certain network configurations, particularly those involving multipath routing. In this article, we will delve into the details of this error, its causes, and potential solutions. We will also explore the underlying technology and provide insights into how to troubleshoot and resolve this issue.

What is the DNX_NH_UNILIST_INSTALL_MULTIPATH Error?

The DNX_NH_UNILIST_INSTALL_MULTIPATH error is typically encountered in network devices, such as routers or switches, that support multipath routing. The error message itself is quite cryptic and may vary depending on the specific device and configuration. However, the general format of the error message is as follows:

dnx_nh_unilist_install_multipath: Failed to create shadow obj 0x20017ff0 for NH 766(FEC 0x2000109f) unilist nh 2097161. Error -14(No resources for operation)

Let’s break down the components of this error message:

  • dnx_nh_unilist_install_multipath: This is the function or process that encountered the error.
  • Failed to create shadow obj 0x20017ff0: This indicates that the device was unable to create a shadow object, which is a critical component in multipath routing.
  • for NH 766(FEC 0x2000109f): This specifies the next-hop (NH) and forwarding equivalence class (FEC) associated with the error.
  • unilist nh 2097161: This refers to the unilist next-hop, which is a data structure used in multipath routing.
  • Error -14(No resources for operation): This is the actual error code and message, indicating that the device lacks sufficient resources to perform the required operation.

Causes of the DNX_NH_UNILIST_INSTALL_MULTIPATH Error

The DNX_NH_UNILIST_INSTALL_MULTIPATH error can be caused by a variety of factors, including:

  • Insufficient resources: The device may not have sufficient memory, CPU, or other resources to handle the demands of multipath routing.
  • Configuration issues: Incorrect or incomplete configuration of multipath routing can lead to this error.
  • Software bugs: Firmware or software issues can cause the device to malfunction and produce this error.
  • Hardware limitations: The device’s hardware may not be capable of supporting the required number of multipath routes or next-hops.

Troubleshooting the DNX_NH_UNILIST_INSTALL_MULTIPATH Error

Troubleshooting this error requires a systematic approach. Here are some steps to help you identify and potentially resolve the issue:

  • Verify configuration: Check the device’s configuration to ensure that multipath routing is correctly set up and that all required parameters are properly configured.
  • Check resource utilization: Monitor the device’s resource utilization to determine if it is experiencing resource constraints.
  • Software and firmware checks: Verify that the device is running the latest software and firmware versions.
  • Hardware checks: Inspect the device’s hardware to ensure that it is functioning correctly and that there are no signs of physical damage.

Resolving the DNX_NH_UNILIST_INSTALL_MULTIPATH Error

Once you have identified the cause of the error, you can take steps to resolve it. Here are some potential solutions:

  • Adjust configuration: Correct any configuration issues or adjust parameters to ensure that multipath routing is properly set up.
  • Upgrade software or firmware: Update the device’s software or firmware to the latest version to resolve any bugs or issues.
  • Add resources: Increase the device’s resources, such as memory or CPU, to handle the demands of multipath routing.
  • Replace hardware: If the device’s hardware is faulty or insufficient, consider replacing it with a more capable device.

Conclusion

The DNX_NH_UNILIST_INSTALL_MULTIPATH error is a complex issue that can be challenging to resolve. However, by understanding the causes and taking a systematic approach to troubleshooting, you can identify and potentially resolve the issue. Remember to verify configuration, check resource utilization, and inspect hardware to determine the root cause of the error. With patience and persistence, you can resolve the DNX_NH_UNILIST_INSTALL_MULTIPATH error and ensure that your network is running smoothly and efficiently.

Recommendations

To avoid encountering the DNX_NH_UNILIST_INSTALL_MULTIPATH error in the future, consider the following recommendations:

  • Regularly review and update your device’s configuration to ensure that it is optimized for multipath routing.
  • Monitor resource utilization to detect potential issues before they become critical.
  • Stay up-to-date with the latest software and firmware versions to ensure that your device has the latest features and bug fixes.
  • Consider upgrading to more capable hardware if your device is struggling to handle the demands of multipath routing.

By following these recommendations, you can minimize the risk of encountering the DNX_NH_UNILIST_INSTALL_MULTIPATH error and ensure that your network is running smoothly and efficiently.

Related Post

PEM 0 High Temp

Understanding PEM 0 High Temp: A Comprehensive Guide P...

[SSR/MIST] How to upgrade SSR device on Mist

Upgrading Your SSR Device on the Mist Portal: A Step-by...

Application Problems Post-Upgrade Due to TCP

In the ever-evolving landscape of Information and Commu...