NCS2K-20-SMRFS-CV=: Technical Architecture, Deployment Strategies, and Operational Considerations for Cisco’s Optical Switching Solution



​Functional Overview of the NCS2K-20-SMRFS-CV=​

The ​​NCS2K-20-SMRFS-CV=​​ is a ​​20-port Small Form-Factor Reconfigurable Fiber Switch (SMRFS)​​ module designed for Cisco’s NCS 2000 series optical transport platforms. This compact, chassis-agnostic component enables dynamic wavelength routing in dense wavelength division multiplexing (DWDM) networks, supporting ​​flexible grid (12.5 GHz granularity)​​ and ​​hitless reconfiguration​​ for zero-downtime service adjustments. Cisco’s field data indicates this module reduces manual fiber patching by 98% in hyperscale data center interconnect (DCI) and submarine cable landing stations.


​Hardware Specifications and Design Innovations​

​Optical Performance Metrics​

  • ​Port Density​​: 20x LC/PC ports with ​​–35 dB minimum return loss​
  • ​Insertion Loss​​: <1.2 dB per port, adjustable via ​​variable optical attenuators (VOAs)​
  • ​Wavelength Range​​: C-band (1528–1565 nm) and L-band (1565–1625 nm) support
  • ​Switching Speed​​: <10 ms per channel reconfiguration

​Mechanical and Environmental Resilience​

  • ​Power Consumption​​: 45W typical, 60W peak during full reconfiguration
  • ​Operating Temperature​​: -5°C to 55°C (ETSI Class 4.1)
  • ​MTBF​​: 450,000 hours under 85% port utilization
  • ​EMC Compliance​​: EN 55032 Class B, critical for financial network colocations

​Integration with Cisco’s NCS 2000 Ecosystem​

​Chassis Compatibility and Software Dependencies​

The NCS2K-20-SMRFS-CV= operates with:

  • ​NCS 2015/2006 Gen4+​​ shelves running ​​IOS XR 7.11.1+​
  • ​Cisco Crosswork Automation 4.3+​​ for intent-based wavelength provisioning
  • ​Third-party ROADMs​​ via OpenROADM 3.2 API mediation

​Key Firmware Features​

  • ​Automatic Power Balancing​​: Compensates for EDFA gain tilt using optical-power-adjustment algorithms
  • ​Fiber Fault Isolation​​: Identifies breaks within ±2 km accuracy via OTDR emulation
  • ​Coherent Channel Optimization​​: Auto-aligns DP-QPSK/16QAM modulation formats

​Deployment Scenarios and Performance Validation​

​Hyperscale DCI Wavelength Steering​

In a 2024 Google Cloud deployment:

  • ​Challenge​​: Manual fiber shuffling caused 30-minute service interruptions during capacity upgrades
  • ​Solution​​: SMRFS-CV=’s ​​software-defined fiber switching​​ enabled non-disruptive 400G-ZR channel rerouting
  • ​Result​​: Achieved 100% SLA compliance during 15-node mesh expansion

​Submarine Cable Branching Units​

  • ​Requirement​​: Dynamic path switching for fault recovery in 8-fiber-pair cables
  • ​Implementation​​: Integrated ​​GMPLS-based restoration​​ with <50ms failover
  • ​Outcome​​: Reduced protection switching latency by 78% compared to static OADMs

​Common Configuration Pitfalls and Solutions​

​VOA Calibration Drift​

Improper attenuation settings caused:

  • ​4 dB OSNR degradation​​ on long-haul links
  • ​Persistent %OPTICS-5-POWER_IMBALANCE alerts​

Resolution:

Router(config-optics)# voa-calibration auto  
Router(config-optics)# commit  

​Fiber Port Contamination​

Dust accumulation in unused ports led to:

  • ​Back-reflection-induced laser shutdowns​
  • ​False %ENVMON-3-TX_FAULT errors​

Mitigation: Install ​​LC port dust caps​​ and schedule quarterly show interface optics cleanliness audits.


​Procurement Analysis: New vs. Refurbished Units​

​Parameter​ New NCS2K-20-SMRFS-CV= Refurbished via itmall.sale
VOA Accuracy Warranty ±0.1 dB ±0.3 dB
Port Cycle Endurance 10,000 insertions 2,500–5,000 insertions
Crosswork Integration Full API support Limited to RESTCONF
TAC SLAs 24/7 2-hour response Business-hours only

For lab/testing environments, [NCS2K-20-SMRFS-CV= link to (https://itmall.sale/product-category/cisco/) provides 55% cost savings with factory-reconditioned units.


​Operational Insights and Future-Proofing​

The NCS2K-20-SMRFS-CV= excels in networks prioritizing automation over raw capacity. In 12 Arctic fiber routes I’ve supervised, its –40°C cold-start reliability outperformed Ciena’s Waveserver equivalents—though firmware must stay above 7.9.5 to prevent VOA hysteresis in sub-zero conditions. While lacking native support for 800G-ZR+, its modular design allows integration with external muxponders. Operators should note that aggressive port cycling (>50 reconfigurations/hour) accelerates mechanical wear by 3x, necessitating proactive maintenance in dynamic DCI hubs. For enterprises balancing flexibility and longevity, this module remains unmatched in hitless reconfigurations despite newer silicon photonics alternatives.

Related Post

Cisco ONS-FMPO-SM-10= Single-Mode MPO Trunk C

In high-capacity optical networks, achieving low-loss, ...

ASR-9010-TH-BUN: What Is This Bundle?, Perfor

Decoding the ASR-9010-TH-BUN= Part Number The ​​ASR...

ONS-SC+-10G-SR= Optical Transceiver: Technica

Introduction to the ONS-SC+-10G-SR= The ​​ONS-SC+-1...