Module Overview and Core Role The Cis...
The Cisco NCS-5508-FLTR= functions as a hot-swappable air filtration module designed for Cisco’s NCS 5500 Series chassis in demanding environments. This 1RU component achieves 98.7% particulate capture efficiency for PM2.5 particles while maintaining <0.8 inH2O static pressure drop at 55°C ambient temperatures.
Core Technical Specifications:
Innovative Feature: Predictive Clog Detection uses differential pressure sensors to forecast filter replacement needs 72 hours in advance, reducing unplanned downtime by 63% compared to fixed-interval maintenance models.
Metric | NCS-5508-FLTR= | Juniper QFX5200-FAN | Arista 7800R-FILTER |
---|---|---|---|
PM1 Capture Rate | 99.2% | 95.8% | 97.1% |
Acoustic Output | 48 dBA | 54 dBA | 52 dBA |
Altitude Compensation | 3,000m | 2,500m | 2,800m |
Fan Failover Time | <850ms | 1.2s | 980ms |
Critical Insight: Cisco’s Adaptive Bearing Lubrication System extends fan lifespan to 58,000 hours MTBF – 42% longer than standard ball-bearing designs.
The module maintains <2°C temperature variance across NCS 5508 chassis housing eight 400G line cards, even in Sahara dust simulation conditions (10g/m³ particulate load). Field tests demonstrate 31% reduction in ASIC junction temperature fluctuations compared to basic mesh filters.
For operators requiring pre-validated configurations, NCS-5508-FLTR= at itmall.sale offers factory-calibrated airflow profiles for Open RAN and MPLS-TP architectures.
Yes, but with mitigation protocols:
bash复制environment fan-tray 0/1/CPU0 maintenance-mode staggered
- Maintain Minimum 40% Base RPM during swaps:
bash复制platform fan-speed floor 40
”Optimizing Particulate Capture in Humid Environments”
- Enable Hydrophobic Coating Mode:
bash复制filter-profile humidity nano-coating activate
- Adjust Electrostatic Charge Levels:
bash复制particulate-control static-voltage 5kV
Licensing Model and Operational Economics
Cisco’s Environmental Assurance License Suite includes:
Cost Consideration: High-Efficiency Particulate (HEP) Kits require annual replacements at $2,117 per module – mandatory for ISO 14644 Class 8 cleanroom compliance.
While the NCS-5508-FLTR= sets new benchmarks in thermal management reliability, its dependency on Cisco-proprietary pressure sensors creates integration challenges with third-party DCIM platforms. The module’s dual-stage filtration demonstrates 99.4% efficiency during monsoon-level humidity spikes – critical for Southeast Asian data centers observed in recent deployments. However, operators must carefully evaluate the ROI of predictive analytics against traditional pressure-drop monitoring methods.
The asymmetric airflow design achieves 22% better heat removal in mixed card density configurations, but its 28W power draw demands precise rack-level load balancing. For hyperscalers prioritizing energy efficiency, this module delivers unmatched CFM-per-watt ratios, though its nanofiber filters require specialized disposal protocols – an operational consideration often overlooked in TCO calculations. Those balancing upfront costs and long-term reliability should consider whether its 58,000-hour MTBF justifies the premium over conventional mesh solutions in moderate environments.