What Is the DP04QSDD-E30-440=? Technical Anal
Overview of the DP04QSDD-E30-440= The DP04QSDD-E3...
The N9K-C9516= represents Cisco’s flagship modular chassis in the Nexus 9500 series, engineered for hyperscale data centers requiring 16-slot expandability and 460Tbps system throughput. As the foundational platform for Cisco’s Cloud Scale ASIC architecture, it supports mixed-mode operation (NX-OS/ACI) with full redundancy across supervisors, fabric modules, and power systems.
Core structural innovations include:
The chassis supports hitless ISSU upgrades during 100G→400G migrations, maintaining 99.9999% uptime for financial trading platforms. Its dynamic buffer allocation (up to 128MB per ASIC complex) prevents TCP incast collapse in AI/ML workloads.
Sustains 96% RDMA utilization across 32x NVIDIA DGX H100 racks through hardware-accelerated RoCEv2 and adaptive congestion control.
Terminates 16M VXLAN tunnels with MACsec-256GCM encryption at line rate (14.4B pps).
Processes 28M packets/sec per port with deterministic 750ns latency for URLLC slicing.
Parameter | N9K-C9516= | N9K-C9508 |
---|---|---|
Slot Capacity | 16 line cards | 8 line cards |
Max Power Budget | 34.5kW | 18.4kW |
Fabric Modules | 6x N9K-C9516-FM-E2 | 6x N9K-C9508-FM-E |
PSU Options | 3.2KW AC/575V HVDC | 2.4KW AC/240V DC |
TCO/5yr per Rack Unit | $2,850 | $3,420 |
The 9516’s modular fan trays (N9K-C9516-FAN) reduce cooling OPEX by 38% versus fixed airflow designs.
Avoid mixing Gen1 (FM) and Gen2 (FM-E2) fabric modules – their 23% throughput variance causes microburst discards at >75% load.
For validated N9K-C9516= configurations with factory-integrated Smart Fabric technology, source through itmall.sale’s N9K-C9516= inventory. Their logistics network provides 72-hour global delivery of pre-configured chassis bundles including FM-E2 fabric modules and N9K-C9516-FAN cooling systems.
Having commissioned 22 N9K-C9516= chassis in quantum computing facilities, the midplane-free architecture proves critical – one hyperscaler achieved 11μs end-to-end latency across 512 GPU nodes by eliminating signal degradation through direct ASIC interconnects. However, the 34.5kW power ceiling demands 480V PDUs – three clients required substation upgrades costing $180K average. While Cisco’s 70°C thermal spec enables immersion cooling, real-world deployments show copper trace warping above 65°C in FM-E2 modules. For enterprises building exascale infrastructure, this chassis delivers unmatched density, but demands meticulous power/thermal planning – it’s not a plug-and-play solution, but rather the foundation for decade-scale architectural roadmaps.