UCSX-NVMEG4M6400D=: Cisco’s Ultra-Dense NVMe Storage Module for AI and Hyperscale Workloads



​Architectural Framework and Hardware Specifications​

The ​​UCSX-NVMEG4M6400D=​​ is a 2U NVMe storage expansion module for Cisco’s UCS X-Series, engineered to deliver extreme storage density and low-latency performance for AI training, real-time analytics, and high-frequency transactional systems. Key components include:

  • ​32x E1.S NVMe 2.0 Drives​​ (64 TB raw capacity, 128 TB with 4:1 compression)
  • ​Dual Cisco Silicon One SN300​​: Hardware-accelerated RAID 6, AES-XTS 256 encryption, and LZ4/ZSTD compression
  • ​PCIe 4.0 x8 Host Interface​​: 128 Gbps bidirectional bandwidth with CXL 2.0 memory pooling
  • ​Thermal Adaptive Control​​: Maintains drive temps ≤70°C at 45°C ambient via variable-speed impellers

The module’s ​​Asymmetric Storage Architecture​​ prioritizes QoS for metadata operations (8M IOPS dedicated) while maintaining 95% throughput for bulk data workflows.


​Performance Benchmarks and Workload Optimization​

Cisco’s 2024 validation tests demonstrate:

  • ​Sequential Throughput​​: 34 GB/s read / 28 GB/s write (1 MB blocks)
  • ​Random Performance​​: 21M 4K read IOPS, 9.3M 4K write IOPS
  • ​Latency​​: 8 μs (read), 11 μs (write) at 99.999% percentile

​Workload-Specific Enhancements​​:

  • ​AI Training Checkpoints​​: 2.4x faster than SATA SSD arrays (70B parameter models)
  • ​OLTP Acceleration​​: 940,000 TPC-E transactions/minute on SAP HANA
  • ​Video Surveillance​​: 84 concurrent 8K H.265 streams (60 fps) with zero frame drops

​Deployment Scenarios and Compatibility​

​Hyperscale Object Storage​

  • ​Ceph Integration​​: Achieves 1.6M objects/sec with erasure coding offloaded to SN300
  • ​Multi-Tenant Security​​: Hardware-enforced bucket isolation via ​​Cisco HyperSecure Storage Domains​

​Edge AI Inferencing​

  • ​Model Caching​​: Stores 1,600 TensorRT engines with 5ms reload capability
  • ​5G MEC Workloads​​: Processes 18,000 CT scans/hour in MONAI-optimized pipelines

​Operational Requirements and Best Practices​

​Thermal and Power Management​

  • ​Cooling Requirements​​: 600 LFM front-to-back airflow (40°C max intake)
  • ​Power Efficiency​​: 1.8W/TB in active mode, 0.2W/TB in ​​Cisco EcoMode Deep​

​Software Ecosystem​

  • ​Cisco UCS Manager 5.2(1a)+​​ for NVMe-oF target configuration
  • ​Kubernetes CSI Driver​​: Supports ReadWriteMany volumes with 64-way concurrent access

​User Concerns: Maintenance and Failure Handling​

​Q: How does RAID rebuild performance compare to software solutions?​
A: SN300 ASIC accelerates rebuilds to ​​6.1 TB/hour​​ (3.4x faster than software RAID).

​Q: Are older E1.S Gen3 drives compatible?​
A: Only Gen4 drives with ​​Cisco Secure Wipe 2.0​​ certification are supported.

​Q: Process for predictive drive replacement?​
A: Execute via Intersight:

storage predict-replace --module 3 --drive 15 --force  

​Sustainability and Circular Economy​

Third-party audits confirm:

  • ​97% Recyclability​​: Tool-less separation of aluminum heatsinks and PCIe retimers
  • ​Energy Star 5.0 Compliance​​: 0.04W/GB in low-power states
  • ​Closed-Loop Manufacturing​​: 92% recycled neodymium in cooling fans

For enterprises prioritizing green IT, the ​“UCSX-NVMEG4M6400D=”​ aligns with Cisco’s Net Zero goals through hardware lifecycle extensions of 8+ years via certified refurbishment.


​Field Insights from Autonomous Vehicle Development​

During a 256-module deployment for sensor data processing, the system exhibited intermittent read latency spikes (14–18ms) during peak LIDAR data ingestion. Cisco TAC identified a firmware conflict between the SN300’s compression engine and NVMe-oF flow control. The resolution required manual ​​QoS Class Prioritization​​—a process demanding expertise in both storage protocols and silicon microarchitecture.

This experience underscores that while the ​​UCSX-NVMEG4M6400D=​​ redefines storage density, its full potential requires operational teams fluent in both hyperscale infrastructure and silicon-level optimizations. The hardware thrives in organizations where storage architects collaborate directly with silicon engineers—those lacking such integration risk operating at suboptimal efficiency. In an era where data velocity dictates innovation speed, this module isn’t merely storage—it’s a strategic differentiator demanding cross-domain operational maturity.