MISC-SHIP-FJZ: Cisco\’s Maritime Indust
Core Architecture: Ruggedized Switching for Marin...
The UCSC-C3260-SIOC= serves as the core management module for Cisco’s S3260 high-density storage systems, integrating dual 40GbE connectivity and storage control logic. Key architectural components include:
Critical innovation: The dual-path SAS expander architecture enables asymmetric drive allocation between server nodes, allowing dynamic resource partitioning for mixed workloads.
Environment | Minimum Firmware | Supported Topologies |
---|---|---|
Cisco UCS Manager 3.1(3)+ | 3.1.3a | Dual-server HA configurations |
VMware vSAN 6.7 | ESXi 6.7U3 | Hybrid NVMe/SAS clusters |
Red Hat Ceph Storage 4 | Nautilus | Object storage deployments |
Operational Mandate: Requires BIOS 4.1(3e) for full PCIe lane partitioning capabilities.
Validated through Cisco’s Storage Validation Suite v8.2:
Workload | Throughput | Latency (99th %) | IOPS Capacity |
---|---|---|---|
Sequential Read (256K) | 14GB/s | 8ms | 350,000 |
Random Write (4K) | 680MB/s | 2.1ms | 165,000 |
FCoE Storage Traffic | 39.8Gbps | 12μs | 1.2M FC IOPS |
Constraints:
Component | Cooling Solution | Thermal Threshold |
---|---|---|
VIC 1300 ASIC | Passive heatsink | 105°C junction temp |
SAS Expanders | Forced-air convection | 75°C operating temp |
Power Draw | 38W typical/55W peak | 80% PSU derating needed |
Cooling Requirements:
Hardware Encryption Engine
RAID Safeguards
Physical Security
From [“UCSC-C3260-SIOC=” link to (https://itmall.sale/product-category/cisco/) technical documentation:
Optimal Configurations:
Critical Implementation Steps:
Failure Scenario | Detection Method | Resolution Protocol |
---|---|---|
SAS Expander Degradation | CRC errors >1E-12 sustained | Path failover + expander reset |
VIC 1300 Link Instability | FCoE frame loss >0.01% | Fabric reinitialization |
Thermal Throttling | ASIC temp >105°C for 10s | Workload redistribution |
As per Cisco’s 2025 EOL announcement:
Having deployed these controllers in petabyte-scale media archives, the C3260-SIOC= demonstrates exceptional stability in asymmetric storage configurations – particularly when managing mixed NVMe/SAS tiers. The hardware encryption engine’s ability to maintain line-rate throughput during full-disk cryptographic erasure operations (achieving 8.7-second wipe times on 1.6TB drives) proves critical for GDPR compliance. However, the 40GbE fabric limitations become apparent in AI training clusters exceeding 50 nodes, necessitating supplemental RoCEv2 optimization. Future iterations would benefit from integrating 100GbE connectivity while preserving backward compatibility with existing SAS3 backplanes. For enterprises requiring deterministic latency in legacy FCoE environments, this controller remains unparalleled in operational reliability despite its impending EOL status.