HCI-P-ID10GC-M6=: How Does This Cisco 10G NIC
Technical Profile of the HCI-P-ID10GC-M6= The HCI...
The UCSC-C225-M8S= is a 1U single-socket rack server optimized for high-density compute and storage workloads, featuring 4th Gen AMD EPYC 9004/9005 Series processors with up to 192 cores and 4800 MT/s DDR5 memory via 12 DIMM slots. Designed for AI/ML, virtualization, and hyperscale storage, it supports 10x 2.5″ SFF NVMe/SAS/SATA drives with Cisco 12G SAS Modular RAID Controller and tri-mode RAID support (SAS4/NVMe hardware RAID). Key connectivity includes 3x PCIe 5.0 x16 slots for accelerators like NVIDIA H100-NVL GPUs and Cisco UCS VIC 15000 Series adapters enabling 200GbE RoCEv3.
The server integrates Cisco TAF 2.0 (Thermal Adaptive Flow) with liquid-assisted rear-door heat exchangers and variable-speed fans (2,000–15,000 RPM). In a genomic sequencing deployment with 8x 16TB NVMe drives, this system maintained drive temperatures below 48°C while reducing energy consumption by 37% compared to air-cooled alternatives.
The Cisco UCS 12G SAS Modular RAID Controller operates in dual modes:
Cisco’s internal testing (UCS C-Series M8 Validation Report) demonstrates:
Workload | UCSC-C225-M8S= | Intel Xeon Scalable 8462Y+ |
---|---|---|
SPECrate2017_int_base | 643 | 587 |
NVMe-oF 4K Random Read | 1.9M IOPS | 1.1M IOPS |
Power Efficiency (Joules/GB) | 0.08 | 0.12 |
Note: RAID 6 configuration with 20% spare capacity and 64KB strip size.
nvme create-ns /dev/nvme0 -s 0x7470e000 -c 0x7470e000 -f 0
nvme zns create-zone /dev/nvme0n1 -z 256 -c 1024
For VMware vSAN 8.0U2:
esxcli storage pmem namespace create -s 512GB -m interleaved
Root Cause: Impedance mismatch in >1.5m DAC cables
Solution:
lspci -vvv | grep "Link Training"
Diagnosis:
storcli /c0 show all
storcli /c0 set rebuildrate=30%
itmall.sale offers customized UCSC-C225-M8S= configurations with:
Critical validation steps:
mlc --bandwidth_matrix
to validate ≥380 GB/s memory throughputIn three 500-node object storage clusters, RAID 60 rebuild times for 18TB drives averaged 14 hours but frequently triggered false failure alerts due to SAS PHY resets. Implementing staggered rebuilds via cron reduced false positives by 62%:
0 */6 * * * storcli /c0/v0 start rebuild
The C225-M8S= excels in mixed workload environments but demands rigorous airflow planning—a lesson reinforced when underfloor HVAC failures caused 8 drives to throttle simultaneously. For enterprises balancing TCO and computational density, this server redefines expectations when teams master its thermal dynamics and hybrid storage modes.
Documentation referenced: Cisco UCS C225 M8 Installation Guide (2025), PCI-SIG Gen5 Electrical Compliance Specifications, SNIA NVM Express over Fabrics 1.1a.